{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/106272"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/106272","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Assessing the Accuracy of Convective Heat Transfer from Overhead Conductor at Low Wind Speed Using Large Eddy Simulations (LES)","abstract":"This project uses Computational Fluid Dynamics (CFD) to assess the accuracy of the forced cooling term for Real Time Thermal Rating (RTTR) of power lines in overhead conductor codes, IEEE 738 and CIGRÉ 207. The analysis is done for low wind speed, corresponding to Reynolds Number of 1,000, and 3,000. The project uses Large Eddy Simulation (LES) in the ANSYS Fluent software. The primary goal is to calculate the convective heat transfer for cylindrical and stranded conductors in non-turbulent flow and for cylindrical conductors with free-stream turbulence. The results showed that the heat transfer correlations used in the codes are accurate for low turbulent flows and that the stranded conductor causes an increase in heat transfer of ~9 % over a cylindrical conductor at low wind speed. The constant heat flux boundary condition experiences ~15 % higher Nusselt Number than uniform temperature boundary condition. The calculated increase in heat transfer due to turbulence was significant; increased heat transfer due to turbulence ~24 % at Reynolds Number of 3,000 at a turbulence intensity of 8% and length scale to diameter ratio of 0.4.","abstract_html":"This project uses Computational Fluid Dynamics (CFD) to assess the accuracy of the forced cooling term for Real Time Thermal Rating (RTTR) of power lines in overhead conductor codes, IEEE 738 and CIGRÉ 207. The analysis is done for low wind speed, corresponding to Reynolds Number of 1,000, and 3,000. The project uses Large Eddy Simulation (LES) in the ANSYS Fluent software. The primary goal is to calculate the convective heat transfer for cylindrical and stranded conductors in non-turbulent flow and for cylindrical conductors with free-stream turbulence. The results showed that the heat transfer correlations used in the codes are accurate for low turbulent flows and that the stranded conductor causes an increase in heat transfer of ~9 % over a cylindrical conductor at low wind speed. The constant heat flux boundary condition experiences ~15 % higher Nusselt Number than uniform temperature boundary condition. The calculated increase in heat transfer due to turbulence was significant; increased heat transfer due to turbulence ~24 % at Reynolds Number of 3,000 at a turbulence intensity of 8% and length scale to diameter ratio of 0.4.","abstract_has_math":false,"creators":["Abdelhady, Mohamed"],"institution":"Schulich School of Engineering","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Engineering – Mechanical & Manufacturing","degree_department":null,"school":null,"contributors":[],"advisors":["Wood, David"],"committee_chairs":[],"committee_members":["Morton, Christopher","Ware, Antony"],"year":2017,"date_issued":"2017-12-22","date_published":"2017-12-22","updated_at":"2026-11-19T07:35:45Z","subjects":["Heat transfer","Flow around cylinders","Turbulent flow","Heat convection","IEEE 738","CIGRÉ 207"],"languages":["en"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/106272"],"render_values":[{"text":"http://hdl.handle.net/1880/106272","href":"https://hdl.handle.net/1880/106272","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Abdelhady, M. (2017). Assessing the Accuracy of Convective Heat Transfer from Overhead Conductor at Low Wind Speed Using Large Eddy Simulations (LES) (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Abdelhady, M. (2017). Assessing the Accuracy of Convective Heat Transfer from Overhead Conductor at Low Wind Speed Using Large Eddy Simulations (LES) (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/5353","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/5353","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F106272","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F106272","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wood, David"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Morton, Christopher","Ware, Antony"]},{"key":"dc:creator","label":"Author","values":["Abdelhady, Mohamed"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-02"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-01-18T20:47:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-01-18T20:47:21Z"]},{"key":"dc:date.issued","label":"Date","values":["2017-12-22"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Schulich School of Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering – Mechanical & Manufacturing"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:submission_checklist","label":"Thesis Submission Checklist","values":["I confirm that I have submitted all of the required forms to Faculty of Graduate Studies."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Heat transfer","Flow around cylinders","Turbulent flow","Heat convection","IEEE 738","CIGRÉ 207"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Engineering","Engineering--Mechanical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Abdelhady, M. (2017). Assessing the Accuracy of Convective Heat Transfer from Overhead Conductor at Low Wind Speed Using Large Eddy Simulations (LES) (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/5353"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/106272"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This project uses Computational Fluid Dynamics (CFD) to assess the accuracy of the forced cooling term for Real Time Thermal Rating (RTTR) of power lines in overhead conductor codes, IEEE 738 and CIGRÉ 207. The analysis is done for low wind speed, corresponding to Reynolds Number of 1,000, and 3,000. The project uses Large Eddy Simulation (LES) in the ANSYS Fluent software. The primary goal is to calculate the convective heat transfer for cylindrical and stranded conductors in non-turbulent flow and for cylindrical conductors with free-stream turbulence. The results showed that the heat transfer correlations used in the codes are accurate for low turbulent flows and that the stranded conductor causes an increase in heat transfer of ~9 % over a cylindrical conductor at low wind speed. The constant heat flux boundary condition experiences ~15 % higher Nusselt Number than uniform temperature boundary condition. The calculated increase in heat transfer due to turbulence was significant; increased heat transfer due to turbulence ~24 % at Reynolds Number of 3,000 at a turbulence intensity of 8% and length scale to diameter ratio of 0.4."]},{"key":"dc:title","label":"Title","values":["Assessing the Accuracy of Convective Heat Transfer from Overhead Conductor at Low Wind Speed Using Large Eddy Simulations (LES)"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wood, David"],"dc:contributor.committeemember":["Morton, Christopher","Ware, Antony"],"dc:creator":["Abdelhady, Mohamed"],"dc:date":["2018-02"],"dc:date.accessioned":["2018-01-18T20:47:21Z"],"dc:date.available":["2018-01-18T20:47:21Z"],"dc:date.issued":["2017-12-22"],"dc:description.abstract":["This project uses Computational Fluid Dynamics (CFD) to assess the accuracy of the forced cooling term for Real Time Thermal Rating (RTTR) of power lines in overhead conductor codes, IEEE 738 and CIGRÉ 207. The analysis is done for low wind speed, corresponding to Reynolds Number of 1,000, and 3,000. The project uses Large Eddy Simulation (LES) in the ANSYS Fluent software. The primary goal is to calculate the convective heat transfer for cylindrical and stranded conductors in non-turbulent flow and for cylindrical conductors with free-stream turbulence. The results showed that the heat transfer correlations used in the codes are accurate for low turbulent flows and that the stranded conductor causes an increase in heat transfer of ~9 % over a cylindrical conductor at low wind speed. The constant heat flux boundary condition experiences ~15 % higher Nusselt Number than uniform temperature boundary condition. The calculated increase in heat transfer due to turbulence was significant; increased heat transfer due to turbulence ~24 % at Reynolds Number of 3,000 at a turbulence intensity of 8% and length scale to diameter ratio of 0.4."],"dc:identifier.citation":["Abdelhady, M. (2017). Assessing the Accuracy of Convective Heat Transfer from Overhead Conductor at Low Wind Speed Using Large Eddy Simulations (LES) (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/5353"],"dc:identifier.uri":["http://hdl.handle.net/1880/106272"],"dc:language.iso":["en"],"dc:publisher.faculty":["Schulich School of Engineering"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Heat transfer","Flow around cylinders","Turbulent flow","Heat convection","IEEE 738","CIGRÉ 207"],"dc:subject.classification":["Engineering","Engineering--Mechanical"],"dc:title":["Assessing the Accuracy of Convective Heat Transfer from Overhead Conductor at Low Wind Speed Using Large Eddy Simulations (LES)"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering – Mechanical & Manufacturing"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"],"thesis:submission_checklist":["I confirm that I have submitted all of the required forms to Faculty of Graduate Studies."]},"updated_at":"2026-11-19T07:35:45Z"}