{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/106337"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/106337","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Method for Optimizing Quantitative Temporal Lobe Epilepsy MR Imaging","abstract":"Many neurological disorders such as epilepsy rely on MRI for detection of structural abnormalities. However, the current clinical MRI methods are insufficient and insensitive in detection of subtle abnormalities. MRI quantitative T2 mapping is a promising quantitative medical imaging technique as it is highly sensitive to tissue composition. The conventional approach for T2 mapping assumes mono-exponential signal decay; however, this is rarely observed due to transmit field inhomogeneity and miscalibration at high field MRIs. The nonexponentially results in poor fits and a systematic bias in estimated decay rates. A recently proposed fitting method, called stimulated echo correction, uses the same input data but estimates the major confounds associated with mono-exponential fitting. Optimal accuracy and non-optimal precision is achieved in this method. My first aim was to develop a stimulated echo correction based method with fewer parameters and higher precision relative to the original one. The second aim was to implement this new method in order to better identify abnormal brain regions in temporal lobe epilepsy that were poorly visualized on standard images. I hypothesized that my improved stimulated echo correction with fewer parameters would provide more accurate and reliable transverse relaxometry imaging than does conventional or the original stimulated echo correction fitting methods, and would improve our ability to detect subtle irregularities associated with epilepsy. The new method was evaluated with simulated and in-vivo data, in which up to 27% reduction in variance in the new method compared to the original stimulated echo correction was observed. Moreover, the new method had greater reliability in categorizing abnormalities in hippocampal regions when compared with exponential and stimulated echo correction methods. I concluded that the new method is able to reduce the variance in T2 relaxometry from multi-echo spin echo sequences; therefore, this method can potentially help in detection of those lesser obvious hippocampus abnormalities.","abstract_html":"Many neurological disorders such as epilepsy rely on MRI for detection of structural abnormalities. However, the current clinical MRI methods are insufficient and insensitive in detection of subtle abnormalities. MRI quantitative T2 mapping is a promising quantitative medical imaging technique as it is highly sensitive to tissue composition. The conventional approach for T2 mapping assumes mono-exponential signal decay; however, this is rarely observed due to transmit field inhomogeneity and miscalibration at high field MRIs. The nonexponentially results in poor fits and a systematic bias in estimated decay rates. A recently proposed fitting method, called stimulated echo correction, uses the same input data but estimates the major confounds associated with mono-exponential fitting. Optimal accuracy and non-optimal precision is achieved in this method. My first aim was to develop a stimulated echo correction based method with fewer parameters and higher precision relative to the original one. The second aim was to implement this new method in order to better identify abnormal brain regions in temporal lobe epilepsy that were poorly visualized on standard images. I hypothesized that my improved stimulated echo correction with fewer parameters would provide more accurate and reliable transverse relaxometry imaging than does conventional or the original stimulated echo correction fitting methods, and would improve our ability to detect subtle irregularities associated with epilepsy. The new method was evaluated with simulated and in-vivo data, in which up to 27% reduction in variance in the new method compared to the original stimulated echo correction was observed. Moreover, the new method had greater reliability in categorizing abnormalities in hippocampal regions when compared with exponential and stimulated echo correction methods. I concluded that the new method is able to reduce the variance in T2 relaxometry from multi-echo spin echo sequences; therefore, this method can potentially help in detection of those lesser obvious hippocampus abnormalities.","abstract_has_math":false,"creators":["Basiri, Reza"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Lebel, Robert Marc","Federico, Paolo"],"committee_chairs":[],"committee_members":["Agha-Khani, Yahya","Takele Zewdie, Ephrem","Frayne, Richard","Sotero Díaz, Roberto C."],"year":2018,"date_issued":"2018-01-17","date_published":"2018-01-17","updated_at":"2026-11-19T07:24:35Z","subjects":["MRI","Medical Imaging","Relaxometry","T2","Epilepsy"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/106337"],"render_values":[{"text":"http://hdl.handle.net/1880/106337","href":"https://hdl.handle.net/1880/106337","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/5418","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/5418","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F106337","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F106337","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lebel, Robert Marc","Federico, Paolo"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Agha-Khani, Yahya","Takele Zewdie, Ephrem","Frayne, Richard","Sotero Díaz, Roberto C."]},{"key":"dc:creator","label":"Author","values":["Basiri, Reza"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-02"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-01-25T19:15:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-01-25T19:15:58Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-01-17"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies","Schulich School of Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:submission_checklist","label":"Thesis Submission Checklist","values":["I confirm that I have submitted all of the required forms to Faculty of Graduate Studies."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["MRI","Medical Imaging","Relaxometry","T2","Epilepsy"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Education--Health","Education--Sciences","Biophysics--Medical","Radiology","Engineering--Biomedical","Psychology--Clinical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Basiri, R. (2018). Method for Optimizing Quantitative Temporal Lobe Epilepsy MR Imaging (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/5418"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/5418"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/106337"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Many neurological disorders such as epilepsy rely on MRI for detection of structural abnormalities. However, the current clinical MRI methods are insufficient and insensitive in detection of subtle abnormalities. MRI quantitative T2 mapping is a promising quantitative medical imaging technique as it is highly sensitive to tissue composition. The conventional approach for T2 mapping assumes mono-exponential signal decay; however, this is rarely observed due to transmit field inhomogeneity and miscalibration at high field MRIs. The nonexponentially results in poor fits and a systematic bias in estimated decay rates. A recently proposed fitting method, called stimulated echo correction, uses the same input data but estimates the major confounds associated with mono-exponential fitting. Optimal accuracy and non-optimal precision is achieved in this method. My first aim was to develop a stimulated echo correction based method with fewer parameters and higher precision relative to the original one. The second aim was to implement this new method in order to better identify abnormal brain regions in temporal lobe epilepsy that were poorly visualized on standard images. I hypothesized that my improved stimulated echo correction with fewer parameters would provide more accurate and reliable transverse relaxometry imaging than does conventional or the original stimulated echo correction fitting methods, and would improve our ability to detect subtle irregularities associated with epilepsy. The new method was evaluated with simulated and in-vivo data, in which up to 27% reduction in variance in the new method compared to the original stimulated echo correction was observed. Moreover, the new method had greater reliability in categorizing abnormalities in hippocampal regions when compared with exponential and stimulated echo correction methods. I concluded that the new method is able to reduce the variance in T2 relaxometry from multi-echo spin echo sequences; therefore, this method can potentially help in detection of those lesser obvious hippocampus abnormalities."]},{"key":"dc:title","label":"Title","values":["Method for Optimizing Quantitative Temporal Lobe Epilepsy MR Imaging"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lebel, Robert Marc","Federico, Paolo"],"dc:contributor.committeemember":["Agha-Khani, Yahya","Takele Zewdie, Ephrem","Frayne, Richard","Sotero Díaz, Roberto C."],"dc:creator":["Basiri, Reza"],"dc:date":["2018-02"],"dc:date.accessioned":["2018-01-25T19:15:58Z"],"dc:date.available":["2018-01-25T19:15:58Z"],"dc:date.issued":["2018-01-17"],"dc:description.abstract":["Many neurological disorders such as epilepsy rely on MRI for detection of structural abnormalities. However, the current clinical MRI methods are insufficient and insensitive in detection of subtle abnormalities. MRI quantitative T2 mapping is a promising quantitative medical imaging technique as it is highly sensitive to tissue composition. The conventional approach for T2 mapping assumes mono-exponential signal decay; however, this is rarely observed due to transmit field inhomogeneity and miscalibration at high field MRIs. The nonexponentially results in poor fits and a systematic bias in estimated decay rates. A recently proposed fitting method, called stimulated echo correction, uses the same input data but estimates the major confounds associated with mono-exponential fitting. Optimal accuracy and non-optimal precision is achieved in this method. My first aim was to develop a stimulated echo correction based method with fewer parameters and higher precision relative to the original one. The second aim was to implement this new method in order to better identify abnormal brain regions in temporal lobe epilepsy that were poorly visualized on standard images. I hypothesized that my improved stimulated echo correction with fewer parameters would provide more accurate and reliable transverse relaxometry imaging than does conventional or the original stimulated echo correction fitting methods, and would improve our ability to detect subtle irregularities associated with epilepsy. The new method was evaluated with simulated and in-vivo data, in which up to 27% reduction in variance in the new method compared to the original stimulated echo correction was observed. Moreover, the new method had greater reliability in categorizing abnormalities in hippocampal regions when compared with exponential and stimulated echo correction methods. I concluded that the new method is able to reduce the variance in T2 relaxometry from multi-echo spin echo sequences; therefore, this method can potentially help in detection of those lesser obvious hippocampus abnormalities."],"dc:identifier.citation":["Basiri, R. (2018). Method for Optimizing Quantitative Temporal Lobe Epilepsy MR Imaging (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/5418"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/5418"],"dc:identifier.uri":["http://hdl.handle.net/1880/106337"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies","Schulich School of Engineering"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["MRI","Medical Imaging","Relaxometry","T2","Epilepsy"],"dc:subject.classification":["Education--Health","Education--Sciences","Biophysics--Medical","Radiology","Engineering--Biomedical","Psychology--Clinical"],"dc:title":["Method for Optimizing Quantitative Temporal Lobe Epilepsy MR Imaging"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"],"thesis:submission_checklist":["I confirm that I have submitted all of the required forms to Faculty of Graduate Studies."]},"updated_at":"2026-11-19T07:24:35Z"}