{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/106340"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/106340","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Development of A Novel Reclaiming Process for Degraded Solvents and Glycols from Industrial Gas Processing and Purification","abstract":"Densities, viscosities, refractive indices and electrical conductivities of both artificial degraded and industrial degraded MEA solutions were measured at standard temperature of 298.15 K or 293.15 K. These measurement data are not currently available for the degraded MEA solutions and the reported values are particularly important for monitoring solvent quality and plant performance. A new reclaiming process was developed to continuously separate degradation products and other types of impurities from the solvent. The detailed analysis of the feed stream, the recovered product stream, and the waste stream showed that this novel reclamation technology is capable of removing most of undesirable impurities and restoring the solvent to its original purity at a high recovery rate. The data would be useful for scaling-up and designing the commercial reclaimers, which can meet the solvents’ cleanup targets at low expenditures, low energy consumption, and minimum waste for disposal.","abstract_html":"Densities, viscosities, refractive indices and electrical conductivities of both artificial degraded and industrial degraded MEA solutions were measured at standard temperature of 298.15 K or 293.15 K. These measurement data are not currently available for the degraded MEA solutions and the reported values are particularly important for monitoring solvent quality and plant performance. A new reclaiming process was developed to continuously separate degradation products and other types of impurities from the solvent. The detailed analysis of the feed stream, the recovered product stream, and the waste stream showed that this novel reclamation technology is capable of removing most of undesirable impurities and restoring the solvent to its original purity at a high recovery rate. The data would be useful for scaling-up and designing the commercial reclaimers, which can meet the solvents’ cleanup targets at low expenditures, low energy consumption, and minimum waste for disposal.","abstract_has_math":false,"creators":["Ju, Huitian Jr"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Chemical and Petroleum Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Mahinpey, Nader Jr"],"committee_chairs":[],"committee_members":["Hassanzadeh, Hassan Jr","Ponnurangam, Sathish Jr"],"year":2018,"date_issued":"2018-01-16","date_published":"2018-01-16","updated_at":"2026-11-19T07:37:15Z","subjects":[],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/106340"],"render_values":[{"text":"http://hdl.handle.net/1880/106340","href":"https://hdl.handle.net/1880/106340","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/5421","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/5421","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F106340","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F106340","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mahinpey, Nader Jr"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hassanzadeh, Hassan Jr","Ponnurangam, Sathish Jr"]},{"key":"dc:creator","label":"Author","values":["Ju, Huitian Jr"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-06"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-01-25T19:17:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-01-25T19:17:12Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-01-16"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies","Schulich School of Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Petroleum Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:submission_checklist","label":"Thesis Submission Checklist","values":["I confirm that I have submitted all of the required forms to Faculty of Graduate Studies."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Education--Industrial","Education--Sciences","Education--Technology","Education--Tests and Measurements","Industrial and Labor Relations"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ju, H. (2018). Development of A Novel Reclaiming Process for Degraded Solvents and Glycols from Industrial Gas Processing and Purification (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/5421"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/5421"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/106340"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Densities, viscosities, refractive indices and electrical conductivities of both artificial degraded and industrial degraded MEA solutions were measured at standard temperature of 298.15 K or 293.15 K. These measurement data are not currently available for the degraded MEA solutions and the reported values are particularly important for monitoring solvent quality and plant performance. A new reclaiming process was developed to continuously separate degradation products and other types of impurities from the solvent. The detailed analysis of the feed stream, the recovered product stream, and the waste stream showed that this novel reclamation technology is capable of removing most of undesirable impurities and restoring the solvent to its original purity at a high recovery rate. The data would be useful for scaling-up and designing the commercial reclaimers, which can meet the solvents’ cleanup targets at low expenditures, low energy consumption, and minimum waste for disposal."]},{"key":"dc:title","label":"Title","values":["Development of A Novel Reclaiming Process for Degraded Solvents and Glycols from Industrial Gas Processing and Purification"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mahinpey, Nader Jr"],"dc:contributor.committeemember":["Hassanzadeh, Hassan Jr","Ponnurangam, Sathish Jr"],"dc:creator":["Ju, Huitian Jr"],"dc:date":["2018-06"],"dc:date.accessioned":["2018-01-25T19:17:12Z"],"dc:date.available":["2018-01-25T19:17:12Z"],"dc:date.issued":["2018-01-16"],"dc:description.abstract":["Densities, viscosities, refractive indices and electrical conductivities of both artificial degraded and industrial degraded MEA solutions were measured at standard temperature of 298.15 K or 293.15 K. These measurement data are not currently available for the degraded MEA solutions and the reported values are particularly important for monitoring solvent quality and plant performance. A new reclaiming process was developed to continuously separate degradation products and other types of impurities from the solvent. The detailed analysis of the feed stream, the recovered product stream, and the waste stream showed that this novel reclamation technology is capable of removing most of undesirable impurities and restoring the solvent to its original purity at a high recovery rate. The data would be useful for scaling-up and designing the commercial reclaimers, which can meet the solvents’ cleanup targets at low expenditures, low energy consumption, and minimum waste for disposal."],"dc:identifier.citation":["Ju, H. (2018). Development of A Novel Reclaiming Process for Degraded Solvents and Glycols from Industrial Gas Processing and Purification (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/5421"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/5421"],"dc:identifier.uri":["http://hdl.handle.net/1880/106340"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies","Schulich School of Engineering"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject.classification":["Education--Industrial","Education--Sciences","Education--Technology","Education--Tests and Measurements","Industrial and Labor Relations"],"dc:title":["Development of A Novel Reclaiming Process for Degraded Solvents and Glycols from Industrial Gas Processing and Purification"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemical and Petroleum Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"],"thesis:submission_checklist":["I confirm that I have submitted all of the required forms to Faculty of Graduate Studies."]},"updated_at":"2026-11-19T07:37:15Z"}