{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/106537"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/106537","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Alignment of Freehand 2-D Ultrasound Images for 3-D Volumetric Reconstruction","abstract":"Ultrasound is an imaging modality used in many medical procedures including the diagnosis of diseases in Neonates. We aim to develop a Computer simulation using 3-D ultrasound to teach clinicians how to perform Neonatal head Ultrasound. To achieve this, we need to align a series of 2-D ultrasound data to reconstruct the 3-D volume. The source data was acquired by freehand movement of the ultrasound probe which results in misalignment and incorrect spacing/angle of the 3-D data. Previous techniques used to solve this problem rely on speckles in the ultrasound images. We devised an algorithm to automatically correct the misalignment using 2-D registration and estimate the elevational spacing/angle by optimizing a cost function against a perpendicular reference Image. After running the algorithm on the dataset, we observed significant improvement in the alignment and 3-D structure. This algorithm will facilitate generating 3-D volume data needed to develop a high quality Simulator.","abstract_html":"Ultrasound is an imaging modality used in many medical procedures including the diagnosis of diseases in Neonates. We aim to develop a Computer simulation using 3-D ultrasound to teach clinicians how to perform Neonatal head Ultrasound. To achieve this, we need to align a series of 2-D ultrasound data to reconstruct the 3-D volume. The source data was acquired by freehand movement of the ultrasound probe which results in misalignment and incorrect spacing/angle of the 3-D data. Previous techniques used to solve this problem rely on speckles in the ultrasound images. We devised an algorithm to automatically correct the misalignment using 2-D registration and estimate the elevational spacing/angle by optimizing a cost function against a perpendicular reference Image. After running the algorithm on the dataset, we observed significant improvement in the alignment and 3-D structure. This algorithm will facilitate generating 3-D volume data needed to develop a high quality Simulator.","abstract_has_math":false,"creators":["Onyejekwe, Nwanneka Okeoghene"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Computer Science","degree_department":null,"school":null,"contributors":[],"advisors":["Chan, Sonny"],"committee_chairs":[],"committee_members":["Khorshid, Mohammad","Boyd, Jeffrey Edwin"],"year":2018,"date_issued":"2018-04-23","date_published":"2018-04-23","updated_at":"2026-11-19T07:33:07Z","subjects":[],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/106537"],"render_values":[{"text":"http://hdl.handle.net/1880/106537","href":"https://hdl.handle.net/1880/106537","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/31823","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/31823","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F106537","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F106537","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Chan, Sonny"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Khorshid, Mohammad","Boyd, Jeffrey Edwin"]},{"key":"dc:creator","label":"Author","values":["Onyejekwe, Nwanneka Okeoghene"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-06"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-04-25T14:13:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-04-25T14:13:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-04-23"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies","Science"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Computer Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Computer Science"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Onyejekwe, N. O. (2018). Alignment of Freehand 2-D Ultrasound Images for 3-D Volumetric Reconstruction (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/31823"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/31823"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/106537"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Ultrasound is an imaging modality used in many medical procedures including the diagnosis of diseases in Neonates. We aim to develop a Computer simulation using 3-D ultrasound to teach clinicians how to perform Neonatal head Ultrasound. To achieve this, we need to align a series of 2-D ultrasound data to reconstruct the 3-D volume. The source data was acquired by freehand movement of the ultrasound probe which results in misalignment and incorrect spacing/angle of the 3-D data. Previous techniques used to solve this problem rely on speckles in the ultrasound images. We devised an algorithm to automatically correct the misalignment using 2-D registration and estimate the elevational spacing/angle by optimizing a cost function against a perpendicular reference Image. After running the algorithm on the dataset, we observed significant improvement in the alignment and 3-D structure. This algorithm will facilitate generating 3-D volume data needed to develop a high quality Simulator."]},{"key":"dc:title","label":"Title","values":["Alignment of Freehand 2-D Ultrasound Images for 3-D Volumetric Reconstruction"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Chan, Sonny"],"dc:contributor.committeemember":["Khorshid, Mohammad","Boyd, Jeffrey Edwin"],"dc:creator":["Onyejekwe, Nwanneka Okeoghene"],"dc:date":["2018-06"],"dc:date.accessioned":["2018-04-25T14:13:46Z"],"dc:date.available":["2018-04-25T14:13:46Z"],"dc:date.issued":["2018-04-23"],"dc:description.abstract":["Ultrasound is an imaging modality used in many medical procedures including the diagnosis of diseases in Neonates. We aim to develop a Computer simulation using 3-D ultrasound to teach clinicians how to perform Neonatal head Ultrasound. To achieve this, we need to align a series of 2-D ultrasound data to reconstruct the 3-D volume. The source data was acquired by freehand movement of the ultrasound probe which results in misalignment and incorrect spacing/angle of the 3-D data. Previous techniques used to solve this problem rely on speckles in the ultrasound images. We devised an algorithm to automatically correct the misalignment using 2-D registration and estimate the elevational spacing/angle by optimizing a cost function against a perpendicular reference Image. After running the algorithm on the dataset, we observed significant improvement in the alignment and 3-D structure. This algorithm will facilitate generating 3-D volume data needed to develop a high quality Simulator."],"dc:identifier.citation":["Onyejekwe, N. O. (2018). Alignment of Freehand 2-D Ultrasound Images for 3-D Volumetric Reconstruction (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/31823"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/31823"],"dc:identifier.uri":["http://hdl.handle.net/1880/106537"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies","Science"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject.classification":["Computer Science"],"dc:title":["Alignment of Freehand 2-D Ultrasound Images for 3-D Volumetric Reconstruction"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Computer Science"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:33:07Z"}