{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/107478"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/107478","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Towards the Real-time Monitoring of Achilles Tendon Strain","abstract":"Achilles tendinopathy is an overuse injury affecting jumping athletes, associated with the accumulation of microdamage due to repetitive tendon strain. Surface and footwear modifications may influence tendon strain magnitude. The purpose of this thesis was to examine the influence of surface and footwear modifications on Achilles tendon strain during vertical countermovement jump landings and to quantify the relationship between tendon strain and accelerometer measures. The parameters were quantified for three shoes (Boost™, 55C, and 70C) and three surfaces (ACS, BC3, and MVP) using motion capture, accelerometry, and dynamometry-ultrasound measures. Surface and footwear influenced Achilles tendon strain; strain was lower in the Boost™ shoe and MVP surface conditions. Differences in strain could be due to stiffness or other material properties of the shoes and surfaces. Only weak correlations were found between tendon strain and accelerometer measures, suggesting that data obtained from accelerometers may not reflect internal loading.","abstract_html":"Achilles tendinopathy is an overuse injury affecting jumping athletes, associated with the accumulation of microdamage due to repetitive tendon strain. Surface and footwear modifications may influence tendon strain magnitude. The purpose of this thesis was to examine the influence of surface and footwear modifications on Achilles tendon strain during vertical countermovement jump landings and to quantify the relationship between tendon strain and accelerometer measures. The parameters were quantified for three shoes (Boost™, 55C, and 70C) and three surfaces (ACS, BC3, and MVP) using motion capture, accelerometry, and dynamometry-ultrasound measures. Surface and footwear influenced Achilles tendon strain; strain was lower in the Boost™ shoe and MVP surface conditions. Differences in strain could be due to stiffness or other material properties of the shoes and surfaces. Only weak correlations were found between tendon strain and accelerometer measures, suggesting that data obtained from accelerometers may not reflect internal loading.","abstract_has_math":false,"creators":["Bruce, Olivia Leigh"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Edwards, William Brent"],"committee_chairs":[],"committee_members":["Stefanyshyn, Darren J.","Wiley, James Preston","Bertram, John Edward Arthur"],"year":2018,"date_issued":"2018-07-18","date_published":"2018-07-18","updated_at":"2026-11-19T07:37:35Z","subjects":["Biomechanics","surface","Footwear","musculoskeletal model"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/107478"],"render_values":[{"text":"http://hdl.handle.net/1880/107478","href":"https://hdl.handle.net/1880/107478","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/32660","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/32660","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F107478","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F107478","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Edwards, William Brent"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Stefanyshyn, Darren J.","Wiley, James Preston","Bertram, John Edward Arthur"]},{"key":"dc:creator","label":"Author","values":["Bruce, Olivia Leigh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-07-23T15:55:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-07-23T15:55:52Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-07-18"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies","Kinesiology"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomechanics","surface","Footwear","musculoskeletal model"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Engineering--Biomedical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Bruce, O. L. (2018). Towards the Real-time Monitoring of Achilles Tendon Strain (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/32660"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/32660"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/107478"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Achilles tendinopathy is an overuse injury affecting jumping athletes, associated with the accumulation of microdamage due to repetitive tendon strain. Surface and footwear modifications may influence tendon strain magnitude. The purpose of this thesis was to examine the influence of surface and footwear modifications on Achilles tendon strain during vertical countermovement jump landings and to quantify the relationship between tendon strain and accelerometer measures. The parameters were quantified for three shoes (Boost™, 55C, and 70C) and three surfaces (ACS, BC3, and MVP) using motion capture, accelerometry, and dynamometry-ultrasound measures. Surface and footwear influenced Achilles tendon strain; strain was lower in the Boost™ shoe and MVP surface conditions. Differences in strain could be due to stiffness or other material properties of the shoes and surfaces. Only weak correlations were found between tendon strain and accelerometer measures, suggesting that data obtained from accelerometers may not reflect internal loading."]},{"key":"dc:title","label":"Title","values":["Towards the Real-time Monitoring of Achilles Tendon Strain"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Edwards, William Brent"],"dc:contributor.committeemember":["Stefanyshyn, Darren J.","Wiley, James Preston","Bertram, John Edward Arthur"],"dc:creator":["Bruce, Olivia Leigh"],"dc:date":["2018-11"],"dc:date.accessioned":["2018-07-23T15:55:52Z"],"dc:date.available":["2018-07-23T15:55:52Z"],"dc:date.issued":["2018-07-18"],"dc:description.abstract":["Achilles tendinopathy is an overuse injury affecting jumping athletes, associated with the accumulation of microdamage due to repetitive tendon strain. Surface and footwear modifications may influence tendon strain magnitude. The purpose of this thesis was to examine the influence of surface and footwear modifications on Achilles tendon strain during vertical countermovement jump landings and to quantify the relationship between tendon strain and accelerometer measures. The parameters were quantified for three shoes (Boost™, 55C, and 70C) and three surfaces (ACS, BC3, and MVP) using motion capture, accelerometry, and dynamometry-ultrasound measures. Surface and footwear influenced Achilles tendon strain; strain was lower in the Boost™ shoe and MVP surface conditions. Differences in strain could be due to stiffness or other material properties of the shoes and surfaces. Only weak correlations were found between tendon strain and accelerometer measures, suggesting that data obtained from accelerometers may not reflect internal loading."],"dc:identifier.citation":["Bruce, O. L. (2018). Towards the Real-time Monitoring of Achilles Tendon Strain (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/32660"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/32660"],"dc:identifier.uri":["http://hdl.handle.net/1880/107478"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies","Kinesiology"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Biomechanics","surface","Footwear","musculoskeletal model"],"dc:subject.classification":["Engineering--Biomedical"],"dc:title":["Towards the Real-time Monitoring of Achilles Tendon Strain"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:37:35Z"}