{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/107781"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/107781","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Investigation of Volumetric Modulated Arc Therapy Dosimetry: from Planning to Delivery","abstract":"Volumetric modulated arc therapy (VMAT) for cancer treatment uses high-energy radiation to kill malignant cells. The general goal is to deliver a high and conformal dose to the target while minimizing dose to organs-at-risk. This thesis focuses on two areas in VMAT: developing high quality treatment plans and assessing the dosimetric impact of delivering pre-designed plans to patients whose anatomy and position change during treatment. Firstly, a quantitative assessment was made by comparing prostate plans optimized with and without a planning target volume upper dose constraint. It was found that removing the target dose uniformity requirement resulted in better rectum sparing and improved tumor control probability. Secondly, the impact of body contour changes on dose distributions for prostate and head and neck VMAT plans was examined. Rules of thumb for dose percentage change and isodose line shift were developed and body contour changes unlikely to require further investigations were addressed.","abstract_html":"Volumetric modulated arc therapy (VMAT) for cancer treatment uses high-energy radiation to kill malignant cells. The general goal is to deliver a high and conformal dose to the target while minimizing dose to organs-at-risk. This thesis focuses on two areas in VMAT: developing high quality treatment plans and assessing the dosimetric impact of delivering pre-designed plans to patients whose anatomy and position change during treatment. Firstly, a quantitative assessment was made by comparing prostate plans optimized with and without a planning target volume upper dose constraint. It was found that removing the target dose uniformity requirement resulted in better rectum sparing and improved tumor control probability. Secondly, the impact of body contour changes on dose distributions for prostate and head and neck VMAT plans was examined. Rules of thumb for dose percentage change and isodose line shift were developed and body contour changes unlikely to require further investigations were addressed.","abstract_has_math":false,"creators":["Sun, Lingyue"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Physics and Astronomy","degree_department":null,"school":null,"contributors":[],"advisors":["Smith, Wendy Lani","Kirkby, Charles"],"committee_chairs":[],"committee_members":["Quon, Harvey C.","Schinkel, Colleen"],"year":2018,"date_issued":"2018-09-10","date_published":"2018-09-10","updated_at":"2026-11-19T07:26:59Z","subjects":["Treatment planning","Treatment delivery","Volumetric modulated arc therapy"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/107781"],"render_values":[{"text":"http://hdl.handle.net/1880/107781","href":"https://hdl.handle.net/1880/107781","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/32944","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/32944","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F107781","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F107781","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Smith, Wendy Lani","Kirkby, Charles"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Quon, Harvey C.","Schinkel, Colleen"]},{"key":"dc:creator","label":"Author","values":["Sun, Lingyue"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-09-20T13:39:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-09-20T13:39:26Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-09-10"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies","Science"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics and Astronomy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Treatment planning","Treatment delivery","Volumetric modulated arc therapy"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Oncology","Chemistry--Radiation","Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Sun, L. (2018). Investigation of Volumetric Modulated Arc Therapy Dosimetry: from Planning to Delivery (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/32944"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/32944"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/107781"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Volumetric modulated arc therapy (VMAT) for cancer treatment uses high-energy radiation to kill malignant cells. The general goal is to deliver a high and conformal dose to the target while minimizing dose to organs-at-risk. This thesis focuses on two areas in VMAT: developing high quality treatment plans and assessing the dosimetric impact of delivering pre-designed plans to patients whose anatomy and position change during treatment. Firstly, a quantitative assessment was made by comparing prostate plans optimized with and without a planning target volume upper dose constraint. It was found that removing the target dose uniformity requirement resulted in better rectum sparing and improved tumor control probability. Secondly, the impact of body contour changes on dose distributions for prostate and head and neck VMAT plans was examined. Rules of thumb for dose percentage change and isodose line shift were developed and body contour changes unlikely to require further investigations were addressed."]},{"key":"dc:title","label":"Title","values":["Investigation of Volumetric Modulated Arc Therapy Dosimetry: from Planning to Delivery"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Smith, Wendy Lani","Kirkby, Charles"],"dc:contributor.committeemember":["Quon, Harvey C.","Schinkel, Colleen"],"dc:creator":["Sun, Lingyue"],"dc:date":["2018-11"],"dc:date.accessioned":["2018-09-20T13:39:26Z"],"dc:date.available":["2018-09-20T13:39:26Z"],"dc:date.issued":["2018-09-10"],"dc:description.abstract":["Volumetric modulated arc therapy (VMAT) for cancer treatment uses high-energy radiation to kill malignant cells. The general goal is to deliver a high and conformal dose to the target while minimizing dose to organs-at-risk. This thesis focuses on two areas in VMAT: developing high quality treatment plans and assessing the dosimetric impact of delivering pre-designed plans to patients whose anatomy and position change during treatment. Firstly, a quantitative assessment was made by comparing prostate plans optimized with and without a planning target volume upper dose constraint. It was found that removing the target dose uniformity requirement resulted in better rectum sparing and improved tumor control probability. Secondly, the impact of body contour changes on dose distributions for prostate and head and neck VMAT plans was examined. Rules of thumb for dose percentage change and isodose line shift were developed and body contour changes unlikely to require further investigations were addressed."],"dc:identifier.citation":["Sun, L. (2018). Investigation of Volumetric Modulated Arc Therapy Dosimetry: from Planning to Delivery (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/32944"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/32944"],"dc:identifier.uri":["http://hdl.handle.net/1880/107781"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies","Science"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Treatment planning","Treatment delivery","Volumetric modulated arc therapy"],"dc:subject.classification":["Oncology","Chemistry--Radiation","Physics"],"dc:title":["Investigation of Volumetric Modulated Arc Therapy Dosimetry: from Planning to Delivery"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics and Astronomy"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:26:59Z"}