{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/110261"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/110261","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Modelling the Impact of Tube Fouling on Heat Transfer in Once-Through Steam Generators","abstract":"In Alberta’s oil sands, once-through steam generators (OTSGs) produce steam for in-situ recovery of bitumen. The industry’s water quality, high recycle, and operating conditions encourage OTSG fouling, with economic, safety, and environmental consequences. Relevant fouling mechanisms are not fully understood, complicating the study of heat transfer in OTSGs via radiation, convection, conduction, and boiling. To progress the study of OTSG fouling, a mathematical model was built in Microsoft Excel, using industry design data, to demonstrate fouling’s heat transfer impacts. This accessible model format is novel. The model demonstrates fouling acts as a thermal resistance to reduce heat transfer efficiency in OTSGs and can increase tube wall temperatures above safe operating limits, potentially causing tube failures. For conductivities between 0.05 – 2 W/m K and thicknesses between 0.1 – 30% of inner radius (0.4 – 11 mm), average tube wall temperatures above safe literature operating limits (i.e. 700 K) are predicted.","abstract_html":"In Alberta’s oil sands, once-through steam generators (OTSGs) produce steam for in-situ recovery of bitumen. The industry’s water quality, high recycle, and operating conditions encourage OTSG fouling, with economic, safety, and environmental consequences. Relevant fouling mechanisms are not fully understood, complicating the study of heat transfer in OTSGs via radiation, convection, conduction, and boiling. To progress the study of OTSG fouling, a mathematical model was built in Microsoft Excel, using industry design data, to demonstrate fouling’s heat transfer impacts. This accessible model format is novel. The model demonstrates fouling acts as a thermal resistance to reduce heat transfer efficiency in OTSGs and can increase tube wall temperatures above safe operating limits, potentially causing tube failures. For conductivities between 0.05 – 2 W/m K and thicknesses between 0.1 – 30% of inner radius (0.4 – 11 mm), average tube wall temperatures above safe literature operating limits (i.e. 700 K) are predicted.","abstract_has_math":false,"creators":["Herman, Steven"],"institution":"Schulich School of Engineering","degree_name":"Master of Engineering (MEng)","degree_level":null,"degree_discipline":"Engineering – Chemical & Petroleum","degree_department":null,"school":null,"contributors":[],"advisors":["Mehrotra, Anil K."],"committee_chairs":[],"committee_members":["Benneker, Anne M.","Gates, Ian Donald","Perdicakis, Basil"],"year":2019,"date_issued":"2019-04-30","date_published":"2019-04-30","updated_at":"2026-11-19T07:13:50Z","subjects":["Fouling","Once-through steam generator","Heat transfer"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/110261"],"render_values":[{"text":"http://hdl.handle.net/1880/110261","href":"https://hdl.handle.net/1880/110261","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Herman, S. (2019). Modelling the Impact of Tube Fouling on Heat Transfer in Once-Through Steam Generators (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Herman, S. (2019). Modelling the Impact of Tube Fouling on Heat Transfer in Once-Through Steam Generators (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/36444","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/36444","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F110261","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F110261","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mehrotra, Anil K."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Benneker, Anne M.","Gates, Ian Donald","Perdicakis, Basil"]},{"key":"dc:creator","label":"Author","values":["Herman, Steven"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-06"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-05-02T22:00:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-05-02T22:00:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-04-30"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Schulich School of Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering – Chemical & Petroleum"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Engineering (MEng)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fouling","Once-through steam generator","Heat transfer"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Herman, S. (2019). Modelling the Impact of Tube Fouling on Heat Transfer in Once-Through Steam Generators (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/36444"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/110261"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In Alberta’s oil sands, once-through steam generators (OTSGs) produce steam for in-situ recovery of bitumen. The industry’s water quality, high recycle, and operating conditions encourage OTSG fouling, with economic, safety, and environmental consequences. Relevant fouling mechanisms are not fully understood, complicating the study of heat transfer in OTSGs via radiation, convection, conduction, and boiling. To progress the study of OTSG fouling, a mathematical model was built in Microsoft Excel, using industry design data, to demonstrate fouling’s heat transfer impacts. This accessible model format is novel. The model demonstrates fouling acts as a thermal resistance to reduce heat transfer efficiency in OTSGs and can increase tube wall temperatures above safe operating limits, potentially causing tube failures. For conductivities between 0.05 – 2 W/m K and thicknesses between 0.1 – 30% of inner radius (0.4 – 11 mm), average tube wall temperatures above safe literature operating limits (i.e. 700 K) are predicted."]},{"key":"dc:title","label":"Title","values":["Modelling the Impact of Tube Fouling on Heat Transfer in Once-Through Steam Generators"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mehrotra, Anil K."],"dc:contributor.committeemember":["Benneker, Anne M.","Gates, Ian Donald","Perdicakis, Basil"],"dc:creator":["Herman, Steven"],"dc:date":["2019-06"],"dc:date.accessioned":["2019-05-02T22:00:18Z"],"dc:date.available":["2019-05-02T22:00:18Z"],"dc:date.issued":["2019-04-30"],"dc:description.abstract":["In Alberta’s oil sands, once-through steam generators (OTSGs) produce steam for in-situ recovery of bitumen. The industry’s water quality, high recycle, and operating conditions encourage OTSG fouling, with economic, safety, and environmental consequences. Relevant fouling mechanisms are not fully understood, complicating the study of heat transfer in OTSGs via radiation, convection, conduction, and boiling. To progress the study of OTSG fouling, a mathematical model was built in Microsoft Excel, using industry design data, to demonstrate fouling’s heat transfer impacts. This accessible model format is novel. The model demonstrates fouling acts as a thermal resistance to reduce heat transfer efficiency in OTSGs and can increase tube wall temperatures above safe operating limits, potentially causing tube failures. For conductivities between 0.05 – 2 W/m K and thicknesses between 0.1 – 30% of inner radius (0.4 – 11 mm), average tube wall temperatures above safe literature operating limits (i.e. 700 K) are predicted."],"dc:identifier.citation":["Herman, S. (2019). Modelling the Impact of Tube Fouling on Heat Transfer in Once-Through Steam Generators (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/36444"],"dc:identifier.uri":["http://hdl.handle.net/1880/110261"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Schulich School of Engineering"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Fouling","Once-through steam generator","Heat transfer"],"dc:subject.classification":["Engineering"],"dc:title":["Modelling the Impact of Tube Fouling on Heat Transfer in Once-Through Steam Generators"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering – Chemical & Petroleum"],"thesis:degree_name":["Master of Engineering (MEng)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:13:50Z"}