{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/110784"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/110784","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Examining Surface Effects on the Swarm Satellite Langmuir Probes","abstract":"The Swarm satellites are equipped with two Langmuir probes to study the plasma environment around Earth. One probe is coated in Titanium nitride and the other in gold, providing a unique opportunity to study surface effects for different coatings. At their altitudes there are neutral particles that may contaminate the probes which adds an uncertainty in their measurements in the form of a time delay. The time delay is most evident by a shift in the current-voltage curve when the upsweep is compared to the downsweep. Using a simple model to fit a simulated current-voltage curve to the sampled curve, it is found that two of the three satellites have a time delay that ranges between 0.627 ms and 1.34 ms. In addition to contamination, there may be additional sources of measurement error that stem from the local environment that are not studied as they are not linked to contamination.","abstract_html":"The Swarm satellites are equipped with two Langmuir probes to study the plasma environment around Earth. One probe is coated in Titanium nitride and the other in gold, providing a unique opportunity to study surface effects for different coatings. At their altitudes there are neutral particles that may contaminate the probes which adds an uncertainty in their measurements in the form of a time delay. The time delay is most evident by a shift in the current-voltage curve when the upsweep is compared to the downsweep. Using a simple model to fit a simulated current-voltage curve to the sampled curve, it is found that two of the three satellites have a time delay that ranges between 0.627 ms and 1.34 ms. In addition to contamination, there may be additional sources of measurement error that stem from the local environment that are not studied as they are not linked to contamination.","abstract_has_math":false,"creators":["Quinn, Candice"],"institution":"Science","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Physics & Astronomy","degree_department":null,"school":null,"contributors":[],"advisors":["Burchill, Johnathan K.","Knudsen, David J."],"committee_chairs":[],"committee_members":["Brown, Jo C.","Cully, Christopher M."],"year":2019,"date_issued":"2019-08-23","date_published":"2019-08-23","updated_at":"2026-11-19T07:36:49Z","subjects":["Swarm","Langmuir Probes","Contamination","Sweep Mode","Harmonic Mode","Model","Plasma"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/110784"],"render_values":[{"text":"http://hdl.handle.net/1880/110784","href":"https://hdl.handle.net/1880/110784","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Quinn, C. (2019). Examining Surface Effects on the Swarm Satellite Langmuir Probes (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Quinn, C. (2019). Examining Surface Effects on the Swarm Satellite Langmuir Probes (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/36866","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/36866","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F110784","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F110784","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Burchill, Johnathan K.","Knudsen, David J."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Brown, Jo C.","Cully, Christopher M."]},{"key":"dc:creator","label":"Author","values":["Quinn, Candice"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-08-26T14:50:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-08-26T14:50:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-08-23"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Science"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics & Astronomy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Swarm","Langmuir Probes","Contamination","Sweep Mode","Harmonic Mode","Model","Plasma"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Quinn, C. (2019). Examining Surface Effects on the Swarm Satellite Langmuir Probes (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/36866"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/110784"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Swarm satellites are equipped with two Langmuir probes to study the plasma environment around Earth. One probe is coated in Titanium nitride and the other in gold, providing a unique opportunity to study surface effects for different coatings. At their altitudes there are neutral particles that may contaminate the probes which adds an uncertainty in their measurements in the form of a time delay. The time delay is most evident by a shift in the current-voltage curve when the upsweep is compared to the downsweep. Using a simple model to fit a simulated current-voltage curve to the sampled curve, it is found that two of the three satellites have a time delay that ranges between 0.627 ms and 1.34 ms. In addition to contamination, there may be additional sources of measurement error that stem from the local environment that are not studied as they are not linked to contamination."]},{"key":"dc:title","label":"Title","values":["Examining Surface Effects on the Swarm Satellite Langmuir Probes"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Burchill, Johnathan K.","Knudsen, David J."],"dc:contributor.committeemember":["Brown, Jo C.","Cully, Christopher M."],"dc:creator":["Quinn, Candice"],"dc:date":["2019-11"],"dc:date.accessioned":["2019-08-26T14:50:00Z"],"dc:date.available":["2019-08-26T14:50:00Z"],"dc:date.issued":["2019-08-23"],"dc:description.abstract":["The Swarm satellites are equipped with two Langmuir probes to study the plasma environment around Earth. One probe is coated in Titanium nitride and the other in gold, providing a unique opportunity to study surface effects for different coatings. At their altitudes there are neutral particles that may contaminate the probes which adds an uncertainty in their measurements in the form of a time delay. The time delay is most evident by a shift in the current-voltage curve when the upsweep is compared to the downsweep. Using a simple model to fit a simulated current-voltage curve to the sampled curve, it is found that two of the three satellites have a time delay that ranges between 0.627 ms and 1.34 ms. In addition to contamination, there may be additional sources of measurement error that stem from the local environment that are not studied as they are not linked to contamination."],"dc:identifier.citation":["Quinn, C. (2019). Examining Surface Effects on the Swarm Satellite Langmuir Probes (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/36866"],"dc:identifier.uri":["http://hdl.handle.net/1880/110784"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Science"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Swarm","Langmuir Probes","Contamination","Sweep Mode","Harmonic Mode","Model","Plasma"],"dc:subject.classification":["Physics"],"dc:title":["Examining Surface Effects on the Swarm Satellite Langmuir Probes"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics & Astronomy"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:36:49Z"}