{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/112672"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/112672","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Enhanced Longitudinal Analysis of Bone Strength Estimated by 3D Bone Imaging and the Finite Element Method","abstract":"Three-dimensional (3D) imaging with high-resolution peripheral quantitative computed tomography (HR-pQCT) and micro-finite element (FE) analysis provides important insight into bone health. Longitudinal analyses of bone morphology maximize precision by using 2D slice-matching registration (SM) or 3D rigid-body registration (3DR) to account for repositioning error between scans, however, the compatibility of these techniques with FE for longitudinal bone strength estimates is limited. This work developed and validated a FE approach for longitudinal HR-pQCT studies using 3DR to maximize reproducibility by fully accounting for misalignment between images. Using a standard imaging protocol, ex vivo (N=10) and in vivo (N=40) distal radius HR-pQCT images were acquired to estimate the efficacy of 3DR to reduce longitudinal variability due to repositioning error and assess the sensitivity of this method to detect true changes in bone strength. In our proposed approach, the full common bone volume defined by 3DR for serial scans was used for FE. Standard FE parameters were estimated by no registration (NR), SM, and 3DR. Ex vivo reproducibility was estimated by the least significant change (LSC) in each parameter with a ground truth of zero change in longitudinal estimates. In vivo reproducibility was estimated by the standard deviation of the rate of change (σ) with an ideal value that was minimized to define true changes in longitudinal estimates. Group-wise comparisons of ex vivo and in vivo reproducibility found that FE reproducibility was improved by both SM (CVRMS<0.80%) and 3DR (CVRMS<0.62%) compared to NR (CVRMS~2%), and 3DR was advantageous as repositioning error increased. Although 3D registration did not negate motion artifacts, it played an important role in detecting and reducing variability in FE estimates for longitudinal study designs. Therefore, 3D registration is ideally suited for estimating in vivo effects of interventions in longitudinal studies of bone strength.","abstract_html":"Three-dimensional (3D) imaging with high-resolution peripheral quantitative computed tomography (HR-pQCT) and micro-finite element (FE) analysis provides important insight into bone health. Longitudinal analyses of bone morphology maximize precision by using 2D slice-matching registration (SM) or 3D rigid-body registration (3DR) to account for repositioning error between scans, however, the compatibility of these techniques with FE for longitudinal bone strength estimates is limited. This work developed and validated a FE approach for longitudinal HR-pQCT studies using 3DR to maximize reproducibility by fully accounting for misalignment between images. Using a standard imaging protocol, ex vivo (N=10) and in vivo (N=40) distal radius HR-pQCT images were acquired to estimate the efficacy of 3DR to reduce longitudinal variability due to repositioning error and assess the sensitivity of this method to detect true changes in bone strength. In our proposed approach, the full common bone volume defined by 3DR for serial scans was used for FE. Standard FE parameters were estimated by no registration (NR), SM, and 3DR. Ex vivo reproducibility was estimated by the least significant change (LSC) in each parameter with a ground truth of zero change in longitudinal estimates. In vivo reproducibility was estimated by the standard deviation of the rate of change (σ) with an ideal value that was minimized to define true changes in longitudinal estimates. Group-wise comparisons of ex vivo and in vivo reproducibility found that FE reproducibility was improved by both SM (CVRMS&lt;0.80%) and 3DR (CVRMS&lt;0.62%) compared to NR (CVRMS~2%), and 3DR was advantageous as repositioning error increased. Although 3D registration did not negate motion artifacts, it played an important role in detecting and reducing variability in FE estimates for longitudinal study designs. Therefore, 3D registration is ideally suited for estimating in vivo effects of interventions in longitudinal studies of bone strength.","abstract_has_math":false,"creators":["Plett, Ryan Michael"],"institution":"Schulich School of Engineering","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Engineering – Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":["Boyd, Steven Kyle"],"committee_chairs":[],"committee_members":["Duncan, Neil A.","Manske, Sarah Lynn","Kim, Keekyoung","Edwards, William Brent"],"year":2020,"date_issued":"2020-10-06","date_published":"2020-10-06","updated_at":"2026-11-19T07:25:25Z","subjects":["Bone Imaging","Finite Element Analysis","Image Registration","HR-pQCT"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/112672"],"render_values":[{"text":"http://hdl.handle.net/1880/112672","href":"https://hdl.handle.net/1880/112672","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Plett, R. M. (2020). Enhanced Longitudinal Analysis of Bone Strength Estimated by 3D Bone Imaging and the Finite Element Method (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Plett, R. M. (2020). Enhanced Longitudinal Analysis of Bone Strength Estimated by 3D Bone Imaging and the Finite Element Method (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/38327","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/38327","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F112672","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F112672","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Boyd, Steven Kyle"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Duncan, Neil A.","Manske, Sarah Lynn","Kim, Keekyoung","Edwards, William Brent"]},{"key":"dc:creator","label":"Author","values":["Plett, Ryan Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-10-07T18:26:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-10-07T18:26:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2020-10-06"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Schulich School of Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering – Biomedical"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bone Imaging","Finite Element Analysis","Image Registration","HR-pQCT"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Radiology","Engineering--Biomedical","Engineering--Mechanical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Plett, R. M. (2020). Enhanced Longitudinal Analysis of Bone Strength Estimated by 3D Bone Imaging and the Finite Element Method (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/38327"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/112672"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Three-dimensional (3D) imaging with high-resolution peripheral quantitative computed tomography (HR-pQCT) and micro-finite element (FE) analysis provides important insight into bone health. Longitudinal analyses of bone morphology maximize precision by using 2D slice-matching registration (SM) or 3D rigid-body registration (3DR) to account for repositioning error between scans, however, the compatibility of these techniques with FE for longitudinal bone strength estimates is limited. This work developed and validated a FE approach for longitudinal HR-pQCT studies using 3DR to maximize reproducibility by fully accounting for misalignment between images. Using a standard imaging protocol, ex vivo (N=10) and in vivo (N=40) distal radius HR-pQCT images were acquired to estimate the efficacy of 3DR to reduce longitudinal variability due to repositioning error and assess the sensitivity of this method to detect true changes in bone strength. In our proposed approach, the full common bone volume defined by 3DR for serial scans was used for FE. Standard FE parameters were estimated by no registration (NR), SM, and 3DR. Ex vivo reproducibility was estimated by the least significant change (LSC) in each parameter with a ground truth of zero change in longitudinal estimates. In vivo reproducibility was estimated by the standard deviation of the rate of change (σ) with an ideal value that was minimized to define true changes in longitudinal estimates. Group-wise comparisons of ex vivo and in vivo reproducibility found that FE reproducibility was improved by both SM (CVRMS<0.80%) and 3DR (CVRMS<0.62%) compared to NR (CVRMS~2%), and 3DR was advantageous as repositioning error increased. Although 3D registration did not negate motion artifacts, it played an important role in detecting and reducing variability in FE estimates for longitudinal study designs. Therefore, 3D registration is ideally suited for estimating in vivo effects of interventions in longitudinal studies of bone strength."]},{"key":"dc:title","label":"Title","values":["Enhanced Longitudinal Analysis of Bone Strength Estimated by 3D Bone Imaging and the Finite Element Method"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Boyd, Steven Kyle"],"dc:contributor.committeemember":["Duncan, Neil A.","Manske, Sarah Lynn","Kim, Keekyoung","Edwards, William Brent"],"dc:creator":["Plett, Ryan Michael"],"dc:date":["2020-11"],"dc:date.accessioned":["2020-10-07T18:26:00Z"],"dc:date.available":["2020-10-07T18:26:00Z"],"dc:date.issued":["2020-10-06"],"dc:description.abstract":["Three-dimensional (3D) imaging with high-resolution peripheral quantitative computed tomography (HR-pQCT) and micro-finite element (FE) analysis provides important insight into bone health. Longitudinal analyses of bone morphology maximize precision by using 2D slice-matching registration (SM) or 3D rigid-body registration (3DR) to account for repositioning error between scans, however, the compatibility of these techniques with FE for longitudinal bone strength estimates is limited. This work developed and validated a FE approach for longitudinal HR-pQCT studies using 3DR to maximize reproducibility by fully accounting for misalignment between images. Using a standard imaging protocol, ex vivo (N=10) and in vivo (N=40) distal radius HR-pQCT images were acquired to estimate the efficacy of 3DR to reduce longitudinal variability due to repositioning error and assess the sensitivity of this method to detect true changes in bone strength. In our proposed approach, the full common bone volume defined by 3DR for serial scans was used for FE. Standard FE parameters were estimated by no registration (NR), SM, and 3DR. Ex vivo reproducibility was estimated by the least significant change (LSC) in each parameter with a ground truth of zero change in longitudinal estimates. In vivo reproducibility was estimated by the standard deviation of the rate of change (σ) with an ideal value that was minimized to define true changes in longitudinal estimates. Group-wise comparisons of ex vivo and in vivo reproducibility found that FE reproducibility was improved by both SM (CVRMS<0.80%) and 3DR (CVRMS<0.62%) compared to NR (CVRMS~2%), and 3DR was advantageous as repositioning error increased. Although 3D registration did not negate motion artifacts, it played an important role in detecting and reducing variability in FE estimates for longitudinal study designs. Therefore, 3D registration is ideally suited for estimating in vivo effects of interventions in longitudinal studies of bone strength."],"dc:identifier.citation":["Plett, R. M. (2020). Enhanced Longitudinal Analysis of Bone Strength Estimated by 3D Bone Imaging and the Finite Element Method (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/38327"],"dc:identifier.uri":["http://hdl.handle.net/1880/112672"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Schulich School of Engineering"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Bone Imaging","Finite Element Analysis","Image Registration","HR-pQCT"],"dc:subject.classification":["Radiology","Engineering--Biomedical","Engineering--Mechanical"],"dc:title":["Enhanced Longitudinal Analysis of Bone Strength Estimated by 3D Bone Imaging and the Finite Element Method"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering – Biomedical"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:25:25Z"}