{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/113880"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/113880","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Tomographic Approach to Human Hydration Assessment: Proof of Concept","abstract":"Hydration is important to human health as water is a vital nutrient used in many physiological functions within the body. While there are many conventional hydration assessment techniques, there is no non-invasive clinical gold standard. This thesis provides a proof of concept for applying standard microwave tomography techniques to assess clinically relevant changes in hydration. A practical and effective tomographic system is designed in simulation for hydration assessment. To improve blind inversions of high contrast objects, a novel regularization parameter selection procedure is introduced. The tomographic hydration assessment technique is validated in silico using realistic forearm models and the effect of measurement noise and positioning is analyzed. Microwave hydration assessment is evaluated in a group of fasting volunteers. This thesis provides promising results for an emerging technique of hydration assessment based on the estimation of changes in permittivity and a practical application of microwave tomography.","abstract_html":"Hydration is important to human health as water is a vital nutrient used in many physiological functions within the body. While there are many conventional hydration assessment techniques, there is no non-invasive clinical gold standard. This thesis provides a proof of concept for applying standard microwave tomography techniques to assess clinically relevant changes in hydration. A practical and effective tomographic system is designed in simulation for hydration assessment. To improve blind inversions of high contrast objects, a novel regularization parameter selection procedure is introduced. The tomographic hydration assessment technique is validated in silico using realistic forearm models and the effect of measurement noise and positioning is analyzed. Microwave hydration assessment is evaluated in a group of fasting volunteers. This thesis provides promising results for an emerging technique of hydration assessment based on the estimation of changes in permittivity and a practical application of microwave tomography.","abstract_has_math":false,"creators":["Besler, Brendon Chisholm Brian"],"institution":"Schulich School of Engineering","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Engineering – Electrical & Computer","degree_department":null,"school":null,"contributors":[],"advisors":["Fear, Elise Carolyn"],"committee_chairs":[],"committee_members":["Okoniewski, Michal","Lamoureux, Michael Phillip"],"year":2021,"date_issued":"2021-09","date_published":"2021-09","updated_at":"2026-11-19T07:33:30Z","subjects":["microwave tomography","microwave imaging","hydration"],"languages":[],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/113880"],"render_values":[{"text":"http://hdl.handle.net/1880/113880","href":"https://hdl.handle.net/1880/113880","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Besler, B. C. B. (2021). Tomographic approach to human hydration assessment: proof of concept (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Besler, B. C. B. (2021). Tomographic approach to human hydration assessment: proof of concept (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/39206","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/39206","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F113880","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F113880","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Fear, Elise Carolyn"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Okoniewski, Michal","Lamoureux, Michael Phillip"]},{"key":"dc:creator","label":"Author","values":["Besler, Brendon Chisholm Brian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-09-16T19:26:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-09-16T19:26:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2021-09"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Schulich School of Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering – Electrical & Computer"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["microwave tomography","microwave imaging","hydration"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Engineering--Biomedical","Engineering--Electronics and Electrical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Besler, B. C. B. (2021). Tomographic approach to human hydration assessment: proof of concept (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/39206"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/113880"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Hydration is important to human health as water is a vital nutrient used in many physiological functions within the body. While there are many conventional hydration assessment techniques, there is no non-invasive clinical gold standard. This thesis provides a proof of concept for applying standard microwave tomography techniques to assess clinically relevant changes in hydration. A practical and effective tomographic system is designed in simulation for hydration assessment. To improve blind inversions of high contrast objects, a novel regularization parameter selection procedure is introduced. The tomographic hydration assessment technique is validated in silico using realistic forearm models and the effect of measurement noise and positioning is analyzed. Microwave hydration assessment is evaluated in a group of fasting volunteers. This thesis provides promising results for an emerging technique of hydration assessment based on the estimation of changes in permittivity and a practical application of microwave tomography."]},{"key":"dc:title","label":"Title","values":["Tomographic Approach to Human Hydration Assessment: Proof of Concept"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Fear, Elise Carolyn"],"dc:contributor.committeemember":["Okoniewski, Michal","Lamoureux, Michael Phillip"],"dc:creator":["Besler, Brendon Chisholm Brian"],"dc:date":["2021-11"],"dc:date.accessioned":["2021-09-16T19:26:22Z"],"dc:date.available":["2021-09-16T19:26:22Z"],"dc:date.issued":["2021-09"],"dc:description.abstract":["Hydration is important to human health as water is a vital nutrient used in many physiological functions within the body. While there are many conventional hydration assessment techniques, there is no non-invasive clinical gold standard. This thesis provides a proof of concept for applying standard microwave tomography techniques to assess clinically relevant changes in hydration. A practical and effective tomographic system is designed in simulation for hydration assessment. To improve blind inversions of high contrast objects, a novel regularization parameter selection procedure is introduced. The tomographic hydration assessment technique is validated in silico using realistic forearm models and the effect of measurement noise and positioning is analyzed. Microwave hydration assessment is evaluated in a group of fasting volunteers. This thesis provides promising results for an emerging technique of hydration assessment based on the estimation of changes in permittivity and a practical application of microwave tomography."],"dc:identifier.citation":["Besler, B. C. B. (2021). Tomographic approach to human hydration assessment: proof of concept (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/39206"],"dc:identifier.uri":["http://hdl.handle.net/1880/113880"],"dc:publisher.faculty":["Schulich School of Engineering"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["microwave tomography","microwave imaging","hydration"],"dc:subject.classification":["Engineering--Biomedical","Engineering--Electronics and Electrical"],"dc:title":["Tomographic Approach to Human Hydration Assessment: Proof of Concept"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering – Electrical & Computer"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:33:30Z"}