{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/115124"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/115124","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"The “Step-Ramp-Step” Protocol: Evaluating the Effects of a Smaller First Step Amplitude and Different Ramp Slopes to Determine the V̇O2 Mean Response Time and the Expression of the V̇O2 Slow Component During Ramp-Incremental Tests","abstract":"The assumption that oxygen uptake (V̇O2) during ramp incremental (RI) testing can be used to prescribe constant-load exercise poses a few pertinent issues. First, this neglects the V̇O2 kinetics and time delay from the working muscles to the site of V̇O2 measurement, referred to as mean response time (MRT). Accurate estimation of the MRT following a RI test to exhaustion is critical for appropriately time-aligning the V̇O2-to-PO relationship. Furthermore, when using RI data, full expression of the delayed V̇O2 response (i.e., the V̇O2 slow component) makes identifying constant-load exercise above gas exchange threshold (GET) to the critical intensity of exercise (maximum metabolic steady state (MMSS), challenging. Therefore, the purpose of this study was to compare the estimated MRT when performing two step transitions of different intensities, and three different ramp rates. Prior to the RI test, using a step transition within the moderate-intensity domain (MOD), the constant-load V̇O2 at a given PO can optimize the estimation of the MRT. Additionally, through utilizing a heavy step transition (~50-65% peak PO) proceeding RI testing, identification of the V̇O2-PO relationship above GET can be made. This previously investigated approach known as the step-ramp-step (SRS) protocol was further applied and tested within this thesis across slow, moderate, and fast RI tests (15, 30 and 45 W·min-1 ramps) in a larger sample size (n=18). The results demonstrated that using a MOD as low as 50 W can result in accurate estimation of MRT for V̇O2. Additionally, identification of the V̇O2-PO relationship at the critical intensity of exercise was consistent irrespective of RI slope. Finally, the PO identified at GET using the 15 W·min-1 ramp was underestimated in comparison to the 30 and 45 W·min-1 ramps. These findings demonstrate the validity of using the SRS protocol with a smaller amplitude step (50W) different RI slope to accurately identify the V̇O2-PO relationship above the GET based on a moderate, and fast ramp, with some discretion required when using slower increasing ramps.","abstract_html":"The assumption that oxygen uptake (V̇O2) during ramp incremental (RI) testing can be used to prescribe constant-load exercise poses a few pertinent issues. First, this neglects the V̇O2 kinetics and time delay from the working muscles to the site of V̇O2 measurement, referred to as mean response time (MRT). Accurate estimation of the MRT following a RI test to exhaustion is critical for appropriately time-aligning the V̇O2-to-PO relationship. Furthermore, when using RI data, full expression of the delayed V̇O2 response (i.e., the V̇O2 slow component) makes identifying constant-load exercise above gas exchange threshold (GET) to the critical intensity of exercise (maximum metabolic steady state (MMSS), challenging. Therefore, the purpose of this study was to compare the estimated MRT when performing two step transitions of different intensities, and three different ramp rates. Prior to the RI test, using a step transition within the moderate-intensity domain (MOD), the constant-load V̇O2 at a given PO can optimize the estimation of the MRT. Additionally, through utilizing a heavy step transition (~50-65% peak PO) proceeding RI testing, identification of the V̇O2-PO relationship above GET can be made. This previously investigated approach known as the step-ramp-step (SRS) protocol was further applied and tested within this thesis across slow, moderate, and fast RI tests (15, 30 and 45 W·min-1 ramps) in a larger sample size (n=18). The results demonstrated that using a MOD as low as 50 W can result in accurate estimation of MRT for V̇O2. Additionally, identification of the V̇O2-PO relationship at the critical intensity of exercise was consistent irrespective of RI slope. Finally, the PO identified at GET using the 15 W·min-1 ramp was underestimated in comparison to the 30 and 45 W·min-1 ramps. These findings demonstrate the validity of using the SRS protocol with a smaller amplitude step (50W) different RI slope to accurately identify the V̇O2-PO relationship above the GET based on a moderate, and fast ramp, with some discretion required when using slower increasing ramps.","abstract_has_math":false,"creators":["Mackie, Mary Zenab"],"institution":"Kinesiology","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Kinesiology","degree_department":null,"school":null,"contributors":[],"advisors":["Murias, Juan"],"committee_chairs":[],"committee_members":["Holash, John","Keir, Daniel"],"year":2022,"date_issued":"2022-08-15","date_published":"2022-08-15","updated_at":"2026-11-19T07:28:26Z","subjects":["Health and Exercise Physiology","Exercise Testing","Cycling","VO2","constant load exercise from ramp data"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/115124"],"render_values":[{"text":"http://hdl.handle.net/1880/115124","href":"https://hdl.handle.net/1880/115124","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Mackie, M. Z. (2022). The “Step-Ramp-Step” Protocol: Evaluating the Effects of a Smaller First Step Amplitude and Different Ramp Slopes to Determine the V̇ O2 Mean Response Time and the Expression of the V̇ O2 Slow Component During Ramp-Incremental Tests (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Mackie, M. Z. (2022). The “Step-Ramp-Step” Protocol: Evaluating the Effects of a Smaller First Step Amplitude and Different Ramp Slopes to Determine the V̇ O2 Mean Response Time and the Expression of the V̇ O2 Slow Component During Ramp-Incremental Tests (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/40160","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/40160","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F115124","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F115124","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Murias, Juan"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Holash, John","Keir, Daniel"]},{"key":"dc:creator","label":"Author","values":["Mackie, Mary Zenab"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-08-22T17:05:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-08-22T17:05:41Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-08-15"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Kinesiology"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Kinesiology"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Health and Exercise Physiology","Exercise Testing","Cycling","VO2","constant load exercise from ramp data"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Education--Health","Physiology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Mackie, M. Z. (2022). The “Step-Ramp-Step” Protocol: Evaluating the Effects of a Smaller First Step Amplitude and Different Ramp Slopes to Determine the V̇ O2 Mean Response Time and the Expression of the V̇ O2 Slow Component During Ramp-Incremental Tests (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/40160"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/115124"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The assumption that oxygen uptake (V̇O2) during ramp incremental (RI) testing can be used to prescribe constant-load exercise poses a few pertinent issues. First, this neglects the V̇O2 kinetics and time delay from the working muscles to the site of V̇O2 measurement, referred to as mean response time (MRT). Accurate estimation of the MRT following a RI test to exhaustion is critical for appropriately time-aligning the V̇O2-to-PO relationship. Furthermore, when using RI data, full expression of the delayed V̇O2 response (i.e., the V̇O2 slow component) makes identifying constant-load exercise above gas exchange threshold (GET) to the critical intensity of exercise (maximum metabolic steady state (MMSS), challenging. Therefore, the purpose of this study was to compare the estimated MRT when performing two step transitions of different intensities, and three different ramp rates. Prior to the RI test, using a step transition within the moderate-intensity domain (MOD), the constant-load V̇O2 at a given PO can optimize the estimation of the MRT. Additionally, through utilizing a heavy step transition (~50-65% peak PO) proceeding RI testing, identification of the V̇O2-PO relationship above GET can be made. This previously investigated approach known as the step-ramp-step (SRS) protocol was further applied and tested within this thesis across slow, moderate, and fast RI tests (15, 30 and 45 W·min-1 ramps) in a larger sample size (n=18). The results demonstrated that using a MOD as low as 50 W can result in accurate estimation of MRT for V̇O2. Additionally, identification of the V̇O2-PO relationship at the critical intensity of exercise was consistent irrespective of RI slope. Finally, the PO identified at GET using the 15 W·min-1 ramp was underestimated in comparison to the 30 and 45 W·min-1 ramps. These findings demonstrate the validity of using the SRS protocol with a smaller amplitude step (50W) different RI slope to accurately identify the V̇O2-PO relationship above the GET based on a moderate, and fast ramp, with some discretion required when using slower increasing ramps."]},{"key":"dc:title","label":"Title","values":["The “Step-Ramp-Step” Protocol: Evaluating the Effects of a Smaller First Step Amplitude and Different Ramp Slopes to Determine the V̇O2 Mean Response Time and the Expression of the V̇O2 Slow Component During Ramp-Incremental Tests"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Murias, Juan"],"dc:contributor.committeemember":["Holash, John","Keir, Daniel"],"dc:creator":["Mackie, Mary Zenab"],"dc:date":["2022-11"],"dc:date.accessioned":["2022-08-22T17:05:41Z"],"dc:date.available":["2022-08-22T17:05:41Z"],"dc:date.issued":["2022-08-15"],"dc:description.abstract":["The assumption that oxygen uptake (V̇O2) during ramp incremental (RI) testing can be used to prescribe constant-load exercise poses a few pertinent issues. First, this neglects the V̇O2 kinetics and time delay from the working muscles to the site of V̇O2 measurement, referred to as mean response time (MRT). Accurate estimation of the MRT following a RI test to exhaustion is critical for appropriately time-aligning the V̇O2-to-PO relationship. Furthermore, when using RI data, full expression of the delayed V̇O2 response (i.e., the V̇O2 slow component) makes identifying constant-load exercise above gas exchange threshold (GET) to the critical intensity of exercise (maximum metabolic steady state (MMSS), challenging. Therefore, the purpose of this study was to compare the estimated MRT when performing two step transitions of different intensities, and three different ramp rates. Prior to the RI test, using a step transition within the moderate-intensity domain (MOD), the constant-load V̇O2 at a given PO can optimize the estimation of the MRT. Additionally, through utilizing a heavy step transition (~50-65% peak PO) proceeding RI testing, identification of the V̇O2-PO relationship above GET can be made. This previously investigated approach known as the step-ramp-step (SRS) protocol was further applied and tested within this thesis across slow, moderate, and fast RI tests (15, 30 and 45 W·min-1 ramps) in a larger sample size (n=18). The results demonstrated that using a MOD as low as 50 W can result in accurate estimation of MRT for V̇O2. Additionally, identification of the V̇O2-PO relationship at the critical intensity of exercise was consistent irrespective of RI slope. Finally, the PO identified at GET using the 15 W·min-1 ramp was underestimated in comparison to the 30 and 45 W·min-1 ramps. These findings demonstrate the validity of using the SRS protocol with a smaller amplitude step (50W) different RI slope to accurately identify the V̇O2-PO relationship above the GET based on a moderate, and fast ramp, with some discretion required when using slower increasing ramps."],"dc:identifier.citation":["Mackie, M. Z. (2022). The “Step-Ramp-Step” Protocol: Evaluating the Effects of a Smaller First Step Amplitude and Different Ramp Slopes to Determine the V̇ O2 Mean Response Time and the Expression of the V̇ O2 Slow Component During Ramp-Incremental Tests (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/40160"],"dc:identifier.uri":["http://hdl.handle.net/1880/115124"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Kinesiology"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Health and Exercise Physiology","Exercise Testing","Cycling","VO2","constant load exercise from ramp data"],"dc:subject.classification":["Education--Health","Physiology"],"dc:title":["The “Step-Ramp-Step” Protocol: Evaluating the Effects of a Smaller First Step Amplitude and Different Ramp Slopes to Determine the V̇O2 Mean Response Time and the Expression of the V̇O2 Slow Component During Ramp-Incremental Tests"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Kinesiology"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:28:26Z"}