{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/115803"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/115803","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"A Multi-Purpose Continuum Robot for Minimally Invasive Surgery","abstract":"This thesis is about ''A Multi-Purpose Continuum Robot for Minimally Invasive surgery'' which consists of five chapters. It starts with an Introduction and Literature Review that studies some of the most famous surgical robotic systems and analyses their pros and cons. Chapter two has to do with the problem statement and challenges that need to be addressed while designing our specific surgical tool, and a CAD design of a flexible continuum robot will be done for our brain surgery application. In chapter three, the kinematic modeling of the proposed robot is analyzed by a new model based on the Euler spirals and the results are compared with conventional constant curvature models. In chapter four, a model predictive control algorithm is proposed that considers the input saturation constraints on robot actuators. Finally, a discussion and conclusion will be provided in chapter five.","abstract_html":"This thesis is about &#x27;&#x27;A Multi-Purpose Continuum Robot for Minimally Invasive surgery&#x27;&#x27; which consists of five chapters. It starts with an Introduction and Literature Review that studies some of the most famous surgical robotic systems and analyses their pros and cons. Chapter two has to do with the problem statement and challenges that need to be addressed while designing our specific surgical tool, and a CAD design of a flexible continuum robot will be done for our brain surgery application. In chapter three, the kinematic modeling of the proposed robot is analyzed by a new model based on the Euler spirals and the results are compared with conventional constant curvature models. In chapter four, a model predictive control algorithm is proposed that considers the input saturation constraints on robot actuators. Finally, a discussion and conclusion will be provided in chapter five.","abstract_has_math":false,"creators":["Esfandiari, Mojtaba"],"institution":"Schulich School of Engineering","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Engineering – Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":["Sutherland, Garnette","Tavakoli, Mahdi"],"committee_chairs":[],"committee_members":["Westwick, David","Goldsmith, Peter"],"year":2023,"date_issued":"2023-01-25","date_published":"2023-01-25","updated_at":"2026-11-19T07:38:26Z","subjects":["Medical Robotics","Continuum Robots","Model Predictive Control"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/115803"],"render_values":[{"text":"http://hdl.handle.net/1880/115803","href":"https://hdl.handle.net/1880/115803","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Esfandiari, M. (2023). A multi-purpose continuum robot for minimally invasive surgery (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Esfandiari, M. (2023). A multi-purpose continuum robot for minimally invasive surgery (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/40708","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/40708","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F115803","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F115803","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sutherland, Garnette","Tavakoli, Mahdi"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Westwick, David","Goldsmith, Peter"]},{"key":"dc:creator","label":"Author","values":["Esfandiari, Mojtaba"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-06"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-02-02T16:57:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-02-02T16:57:59Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-01-25"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Schulich School of Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering – Biomedical"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Medical Robotics","Continuum Robots","Model Predictive Control"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Engineering--Biomedical","Engineering--Mechanical","Robotics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Esfandiari, M. (2023). A multi-purpose continuum robot for minimally invasive surgery (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/40708"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/115803"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis is about ''A Multi-Purpose Continuum Robot for Minimally Invasive surgery'' which consists of five chapters. It starts with an Introduction and Literature Review that studies some of the most famous surgical robotic systems and analyses their pros and cons. Chapter two has to do with the problem statement and challenges that need to be addressed while designing our specific surgical tool, and a CAD design of a flexible continuum robot will be done for our brain surgery application. In chapter three, the kinematic modeling of the proposed robot is analyzed by a new model based on the Euler spirals and the results are compared with conventional constant curvature models. In chapter four, a model predictive control algorithm is proposed that considers the input saturation constraints on robot actuators. Finally, a discussion and conclusion will be provided in chapter five."]},{"key":"dc:title","label":"Title","values":["A Multi-Purpose Continuum Robot for Minimally Invasive Surgery"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sutherland, Garnette","Tavakoli, Mahdi"],"dc:contributor.committeemember":["Westwick, David","Goldsmith, Peter"],"dc:creator":["Esfandiari, Mojtaba"],"dc:date":["2023-06"],"dc:date.accessioned":["2023-02-02T16:57:59Z"],"dc:date.available":["2023-02-02T16:57:59Z"],"dc:date.issued":["2023-01-25"],"dc:description.abstract":["This thesis is about ''A Multi-Purpose Continuum Robot for Minimally Invasive surgery'' which consists of five chapters. It starts with an Introduction and Literature Review that studies some of the most famous surgical robotic systems and analyses their pros and cons. Chapter two has to do with the problem statement and challenges that need to be addressed while designing our specific surgical tool, and a CAD design of a flexible continuum robot will be done for our brain surgery application. In chapter three, the kinematic modeling of the proposed robot is analyzed by a new model based on the Euler spirals and the results are compared with conventional constant curvature models. In chapter four, a model predictive control algorithm is proposed that considers the input saturation constraints on robot actuators. Finally, a discussion and conclusion will be provided in chapter five."],"dc:identifier.citation":["Esfandiari, M. (2023). A multi-purpose continuum robot for minimally invasive surgery (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/40708"],"dc:identifier.uri":["http://hdl.handle.net/1880/115803"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Schulich School of Engineering"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Medical Robotics","Continuum Robots","Model Predictive Control"],"dc:subject.classification":["Engineering--Biomedical","Engineering--Mechanical","Robotics"],"dc:title":["A Multi-Purpose Continuum Robot for Minimally Invasive Surgery"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering – Biomedical"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:38:26Z"}