{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/116297"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/116297","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Design and Evaluation of an Instrumented Equine Shoe for Kinetic Gait Analysis","abstract":"Within the field of equine veterinary medicine, the diagnosis, prevention and treatment of lameness is one of the most challenging problems facing practitioners and horse owners. There is a clear need for a better understanding of the biomechanics of equine locomotion and objective methods of analyzing gait. There are a variety of biomechanical tools that are kinematic or kinetic based. Current methods of kinetic gait analysis include force plates, instrumented treadmills, and instrumented horseshoes. All these devices measure Ground Reaction Forces (GRFs). Force plates are considered the gold standard for kinetic gait analysis but are unable to record successive strides. The instrumented treadmill permits the measurement of successive strides, but measurement can only be performed on a treadmill. The instrumented horseshoe permits the measurement of successive strides on a variety of surfaces, but the technical challenges associated with the development have limited their use to research institutes and universities. The intention of this project is to conceptualize, design, and evaluate an instrumented horseshoe for the analysis of gait in horses. A prototype was developed after determining the design requirements, evaluating a force sensor, integrating the force sensor into the electrical design, developing software for data collection, and developing a mechanical assembly to house the electronics and transfer force to the sensors. Two prototypes were developed within the scope of this project. The first prototype was tested on the forelimb of a test horse and the data collected was evaluated with a post-test sensor characterization to determine the forces applied. The forces measured during the test on the horse were lower than expected. The second prototype was modified slightly, and an additional system was created to permit four self-contained devices to be synchronized in time to measure GRFs from the horse. Data were collected from all four devices. A mechanical failure prevented a proper evaluation of the forces, but temporal data were determined. The goal of future work is to develop a reliable and practical device for longitudinal monitoring of the equine gait to inform our understanding of equine locomotion, supplement lameness exams, and as an outcome measure for research studies.","abstract_html":"Within the field of equine veterinary medicine, the diagnosis, prevention and treatment of lameness is one of the most challenging problems facing practitioners and horse owners. There is a clear need for a better understanding of the biomechanics of equine locomotion and objective methods of analyzing gait. There are a variety of biomechanical tools that are kinematic or kinetic based. Current methods of kinetic gait analysis include force plates, instrumented treadmills, and instrumented horseshoes. All these devices measure Ground Reaction Forces (GRFs). Force plates are considered the gold standard for kinetic gait analysis but are unable to record successive strides. The instrumented treadmill permits the measurement of successive strides, but measurement can only be performed on a treadmill. The instrumented horseshoe permits the measurement of successive strides on a variety of surfaces, but the technical challenges associated with the development have limited their use to research institutes and universities. The intention of this project is to conceptualize, design, and evaluate an instrumented horseshoe for the analysis of gait in horses. A prototype was developed after determining the design requirements, evaluating a force sensor, integrating the force sensor into the electrical design, developing software for data collection, and developing a mechanical assembly to house the electronics and transfer force to the sensors. Two prototypes were developed within the scope of this project. The first prototype was tested on the forelimb of a test horse and the data collected was evaluated with a post-test sensor characterization to determine the forces applied. The forces measured during the test on the horse were lower than expected. The second prototype was modified slightly, and an additional system was created to permit four self-contained devices to be synchronized in time to measure GRFs from the horse. Data were collected from all four devices. A mechanical failure prevented a proper evaluation of the forces, but temporal data were determined. The goal of future work is to develop a reliable and practical device for longitudinal monitoring of the equine gait to inform our understanding of equine locomotion, supplement lameness exams, and as an outcome measure for research studies.","abstract_has_math":false,"creators":["Devolin, Alanna"],"institution":"Schulich School of Engineering","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Engineering – Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":["Scott, W, Michael","Murari, Kartikeya"],"committee_chairs":[],"committee_members":["Edwards, Brent","Bertram, John E.A"],"year":2023,"date_issued":"2023-01-12","date_published":"2023-01-12","updated_at":"2026-11-19T07:12:22Z","subjects":["Instrumentation Design","Kinetic Gait Analysis","Objective Gait Analysis","Embedded System Design","Biomechanics","Equine","Horse"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/116297"],"render_values":[{"text":"http://hdl.handle.net/1880/116297","href":"https://hdl.handle.net/1880/116297","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Devolin, A. (2023). Design and Evaluation of an Instrumented Equine Shoe for Kinetic Gait Analysis (Master thesis). University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca ."],"render_values":[{"text":"Devolin, A. (2023). Design and Evaluation of an Instrumented Equine Shoe for Kinetic Gait Analysis (Master thesis). University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca .","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/dspace/41141","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/dspace/41141","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":"embargoed","embargo_until":"2025-01-12","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F116297","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F116297","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Scott, W, Michael","Murari, Kartikeya"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Edwards, Brent","Bertram, John E.A"]},{"key":"dc:creator","label":"Author","values":["Devolin, Alanna"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["Winter Conferral"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-05-11T04:23:56Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-01-12"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2025-01-12"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Schulich School of Engineering"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering – Biomedical"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Instrumentation Design","Kinetic Gait Analysis","Objective Gait Analysis","Embedded System Design","Biomechanics","Equine","Horse"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Engineering--Biomedical","Engineering--Electronics and Electrical","Biology--Veterinary Science"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Devolin, A. (2023). Design and Evaluation of an Instrumented Equine Shoe for Kinetic Gait Analysis (Master thesis). University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca ."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/dspace/41141"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/116297"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Within the field of equine veterinary medicine, the diagnosis, prevention and treatment of lameness is one of the most challenging problems facing practitioners and horse owners. There is a clear need for a better understanding of the biomechanics of equine locomotion and objective methods of analyzing gait. There are a variety of biomechanical tools that are kinematic or kinetic based. Current methods of kinetic gait analysis include force plates, instrumented treadmills, and instrumented horseshoes. All these devices measure Ground Reaction Forces (GRFs). Force plates are considered the gold standard for kinetic gait analysis but are unable to record successive strides. The instrumented treadmill permits the measurement of successive strides, but measurement can only be performed on a treadmill. The instrumented horseshoe permits the measurement of successive strides on a variety of surfaces, but the technical challenges associated with the development have limited their use to research institutes and universities. The intention of this project is to conceptualize, design, and evaluate an instrumented horseshoe for the analysis of gait in horses. A prototype was developed after determining the design requirements, evaluating a force sensor, integrating the force sensor into the electrical design, developing software for data collection, and developing a mechanical assembly to house the electronics and transfer force to the sensors. Two prototypes were developed within the scope of this project. The first prototype was tested on the forelimb of a test horse and the data collected was evaluated with a post-test sensor characterization to determine the forces applied. The forces measured during the test on the horse were lower than expected. The second prototype was modified slightly, and an additional system was created to permit four self-contained devices to be synchronized in time to measure GRFs from the horse. Data were collected from all four devices. A mechanical failure prevented a proper evaluation of the forces, but temporal data were determined. The goal of future work is to develop a reliable and practical device for longitudinal monitoring of the equine gait to inform our understanding of equine locomotion, supplement lameness exams, and as an outcome measure for research studies."]},{"key":"dc:title","label":"Title","values":["Design and Evaluation of an Instrumented Equine Shoe for Kinetic Gait Analysis"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Scott, W, Michael","Murari, Kartikeya"],"dc:contributor.committeemember":["Edwards, Brent","Bertram, John E.A"],"dc:creator":["Devolin, Alanna"],"dc:date":["Winter Conferral"],"dc:date.accessioned":["2023-05-11T04:23:56Z"],"dc:date.issued":["2023-01-12"],"dc:date.liftdate":["2025-01-12"],"dc:description.abstract":["Within the field of equine veterinary medicine, the diagnosis, prevention and treatment of lameness is one of the most challenging problems facing practitioners and horse owners. There is a clear need for a better understanding of the biomechanics of equine locomotion and objective methods of analyzing gait. There are a variety of biomechanical tools that are kinematic or kinetic based. Current methods of kinetic gait analysis include force plates, instrumented treadmills, and instrumented horseshoes. All these devices measure Ground Reaction Forces (GRFs). Force plates are considered the gold standard for kinetic gait analysis but are unable to record successive strides. The instrumented treadmill permits the measurement of successive strides, but measurement can only be performed on a treadmill. The instrumented horseshoe permits the measurement of successive strides on a variety of surfaces, but the technical challenges associated with the development have limited their use to research institutes and universities. The intention of this project is to conceptualize, design, and evaluate an instrumented horseshoe for the analysis of gait in horses. A prototype was developed after determining the design requirements, evaluating a force sensor, integrating the force sensor into the electrical design, developing software for data collection, and developing a mechanical assembly to house the electronics and transfer force to the sensors. Two prototypes were developed within the scope of this project. The first prototype was tested on the forelimb of a test horse and the data collected was evaluated with a post-test sensor characterization to determine the forces applied. The forces measured during the test on the horse were lower than expected. The second prototype was modified slightly, and an additional system was created to permit four self-contained devices to be synchronized in time to measure GRFs from the horse. Data were collected from all four devices. A mechanical failure prevented a proper evaluation of the forces, but temporal data were determined. The goal of future work is to develop a reliable and practical device for longitudinal monitoring of the equine gait to inform our understanding of equine locomotion, supplement lameness exams, and as an outcome measure for research studies."],"dc:identifier.citation":["Devolin, A. (2023). Design and Evaluation of an Instrumented Equine Shoe for Kinetic Gait Analysis (Master thesis). University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca ."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/dspace/41141"],"dc:identifier.uri":["http://hdl.handle.net/1880/116297"],"dc:language.iso":["English"],"dc:publisher.faculty":["Schulich School of Engineering"],"dc:subject":["Instrumentation Design","Kinetic Gait Analysis","Objective Gait Analysis","Embedded System Design","Biomechanics","Equine","Horse"],"dc:subject.classification":["Engineering--Biomedical","Engineering--Electronics and Electrical","Biology--Veterinary Science"],"dc:title":["Design and Evaluation of an Instrumented Equine Shoe for Kinetic Gait Analysis"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering – Biomedical"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:12:22Z"}