{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/116370"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/116370","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Design and Testing of a Novel Fluid-Cable Actuator","abstract":"This thesis presents the design, development, and investigation of a novel fluid-cable actuator that operates with either air or water as its working fluid. The device employs rolling diaphragms and a concentric cable, anchored to each piston, to offer low-friction actuation for haptic control in human-safe robotics. First, various distinct designs and sizes are explored with special regard paid to diaphragm shape and functionality. Second, specialized procedures for the manufacture of actuator components using methods such as 3D printing (FDM, MSLA), dip coating, and silicone casting are developed. Third, testing on a custom built setup is performed to investigate force following accuracy, the effects of internal pressure on performance, and the maximum load resolution of the transmission. Lastly, proof of concept mechanisms for robotic applications of the actuator are designed and two unique elbow joints are MSLA printed and assembled. The final developed actuator demonstrates minimal lag under hydraulic operation, a force following accuracy as high as 95.7 percent, and the transmission of loads as small as 2 grams from input to output. The actuator eliminates all sliding seals and achieves bidirectional actuation with a single input line while maintaining a high force to weight ratio. The development process also resulted in the creation of a novel split piston design submitted for patent consideration. Finally, next steps and specific areas for further improvement are identified and discussed.","abstract_html":"This thesis presents the design, development, and investigation of a novel fluid-cable actuator that operates with either air or water as its working fluid. The device employs rolling diaphragms and a concentric cable, anchored to each piston, to offer low-friction actuation for haptic control in human-safe robotics. First, various distinct designs and sizes are explored with special regard paid to diaphragm shape and functionality. Second, specialized procedures for the manufacture of actuator components using methods such as 3D printing (FDM, MSLA), dip coating, and silicone casting are developed. Third, testing on a custom built setup is performed to investigate force following accuracy, the effects of internal pressure on performance, and the maximum load resolution of the transmission. Lastly, proof of concept mechanisms for robotic applications of the actuator are designed and two unique elbow joints are MSLA printed and assembled. The final developed actuator demonstrates minimal lag under hydraulic operation, a force following accuracy as high as 95.7 percent, and the transmission of loads as small as 2 grams from input to output. The actuator eliminates all sliding seals and achieves bidirectional actuation with a single input line while maintaining a high force to weight ratio. The development process also resulted in the creation of a novel split piston design submitted for patent consideration. Finally, next steps and specific areas for further improvement are identified and discussed.","abstract_has_math":false,"creators":["Zapote Castilla, Jorge B."],"institution":"Schulich School of Engineering","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Engineering – Mechanical & Manufacturing","degree_department":null,"school":null,"contributors":[],"advisors":["Goldsmith, Peter B.","Brennan, Robert W."],"committee_chairs":[],"committee_members":["Eggermont, Marjan J.","Yanushkevich, Svetlana","Goldsmith, Peter B.","Brennan, Robert W."],"year":2021,"date_issued":"2021-12-06","date_published":"2021-12-06","updated_at":"2026-11-19T07:30:04Z","subjects":["Design","Manufacturing: 3D printing","hydraulics","Invention","Prototyping","Haptics","Telehealth"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/116370"],"render_values":[{"text":"http://hdl.handle.net/1880/116370","href":"https://hdl.handle.net/1880/116370","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Zapote Castilla, J. B. (2021). Design and Testing of a Novel Fluid-Cable Actuator (Master thesis). University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca ."],"render_values":[{"text":"Zapote Castilla, J. B. (2021). Design and Testing of a Novel Fluid-Cable Actuator (Master thesis). University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca .","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/dspace/41214","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/dspace/41214","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":"embargoed","embargo_until":"2999-09-09","access_note":"Embargoed until 2999-09-09"},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F116370","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F116370","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Goldsmith, Peter B.","Brennan, Robert W."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Eggermont, Marjan J.","Yanushkevich, Svetlana","Goldsmith, Peter B.","Brennan, Robert W."]},{"key":"dc:creator","label":"Author","values":["Zapote Castilla, Jorge B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["Winter Conferral"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-05-11T05:05:25Z"]},{"key":"dc:date.issued","label":"Date","values":["2021-12-06"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2999-09-09"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Schulich School of Engineering"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering – Mechanical & Manufacturing"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Design","Manufacturing: 3D printing","hydraulics","Invention","Prototyping","Haptics","Telehealth"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Engineering--Mechanical","Engineering--Biomedical","Engineering--Robotics","Health Sciences--Medicine and Surgery"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Zapote Castilla, J. B. (2021). Design and Testing of a Novel Fluid-Cable Actuator (Master thesis). University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca ."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/dspace/41214"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/116370"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the design, development, and investigation of a novel fluid-cable actuator that operates with either air or water as its working fluid. The device employs rolling diaphragms and a concentric cable, anchored to each piston, to offer low-friction actuation for haptic control in human-safe robotics. First, various distinct designs and sizes are explored with special regard paid to diaphragm shape and functionality. Second, specialized procedures for the manufacture of actuator components using methods such as 3D printing (FDM, MSLA), dip coating, and silicone casting are developed. Third, testing on a custom built setup is performed to investigate force following accuracy, the effects of internal pressure on performance, and the maximum load resolution of the transmission. Lastly, proof of concept mechanisms for robotic applications of the actuator are designed and two unique elbow joints are MSLA printed and assembled. The final developed actuator demonstrates minimal lag under hydraulic operation, a force following accuracy as high as 95.7 percent, and the transmission of loads as small as 2 grams from input to output. The actuator eliminates all sliding seals and achieves bidirectional actuation with a single input line while maintaining a high force to weight ratio. The development process also resulted in the creation of a novel split piston design submitted for patent consideration. Finally, next steps and specific areas for further improvement are identified and discussed."]},{"key":"dc:title","label":"Title","values":["Design and Testing of a Novel Fluid-Cable Actuator"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Goldsmith, Peter B.","Brennan, Robert W."],"dc:contributor.committeemember":["Eggermont, Marjan J.","Yanushkevich, Svetlana","Goldsmith, Peter B.","Brennan, Robert W."],"dc:creator":["Zapote Castilla, Jorge B."],"dc:date":["Winter Conferral"],"dc:date.accessioned":["2023-05-11T05:05:25Z"],"dc:date.issued":["2021-12-06"],"dc:date.liftdate":["2999-09-09"],"dc:description.abstract":["This thesis presents the design, development, and investigation of a novel fluid-cable actuator that operates with either air or water as its working fluid. The device employs rolling diaphragms and a concentric cable, anchored to each piston, to offer low-friction actuation for haptic control in human-safe robotics. First, various distinct designs and sizes are explored with special regard paid to diaphragm shape and functionality. Second, specialized procedures for the manufacture of actuator components using methods such as 3D printing (FDM, MSLA), dip coating, and silicone casting are developed. Third, testing on a custom built setup is performed to investigate force following accuracy, the effects of internal pressure on performance, and the maximum load resolution of the transmission. Lastly, proof of concept mechanisms for robotic applications of the actuator are designed and two unique elbow joints are MSLA printed and assembled. The final developed actuator demonstrates minimal lag under hydraulic operation, a force following accuracy as high as 95.7 percent, and the transmission of loads as small as 2 grams from input to output. The actuator eliminates all sliding seals and achieves bidirectional actuation with a single input line while maintaining a high force to weight ratio. The development process also resulted in the creation of a novel split piston design submitted for patent consideration. Finally, next steps and specific areas for further improvement are identified and discussed."],"dc:identifier.citation":["Zapote Castilla, J. B. (2021). Design and Testing of a Novel Fluid-Cable Actuator (Master thesis). University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca ."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/dspace/41214"],"dc:identifier.uri":["http://hdl.handle.net/1880/116370"],"dc:language.iso":["English"],"dc:publisher.faculty":["Schulich School of Engineering"],"dc:subject":["Design","Manufacturing: 3D printing","hydraulics","Invention","Prototyping","Haptics","Telehealth"],"dc:subject.classification":["Engineering--Mechanical","Engineering--Biomedical","Engineering--Robotics","Health Sciences--Medicine and Surgery"],"dc:title":["Design and Testing of a Novel Fluid-Cable Actuator"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering – Mechanical & Manufacturing"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:30:04Z"}