{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/116493"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/116493","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Leveraging the Advances in Isothermal Nucleic Acid Amplification Technology for Point-Of- Care Diagnostics for Infectious Diseases","abstract":"The COVID-19 pandemic has put immense pressure on diagnostic testing infrastructure. The widely accepted reference standard laboratory testing method for COVID-19 is reverse transcriptase-PCR (RT-PCR). While highly sensitive and specific, RT-PCR tests suffer from their high cost, slow speed, and requirements for specialized instruments and technical expertise. In the community, rapid antigen tests are widely used due to their low cost, rapid speed, and ease of use. However, rapid antigen tests are hindered by their low sensitivity. The goal of this project was to help fill the gap that exists between RT-PCR tests and rapid antigen tests for COVID-19 in terms of cost, sensitivity, specificity, speed, and ease of use. To this end, two RT-LAMP tests for COVID-19 were developed. The key difference between the two tests lies in their extraction methods: one test used a silica column-based extraction method (saliva dry-LAMP) while the other test used heat-inactivated samples (direct dry-LAMP). Direct dry-LAMP was developed to improve on the shortcomings of saliva dry-LAMP. Saliva dry-LAMP was validated to near regulatory standards, while the focus was more on method optimization for the direct dry-LAMP test. For each test, a self-contained portable testing platform was developed to perform all steps of the test. The heat inactivation method in the direct dry-LAMP workflow enabled performance improvements in the areas of speed, simplicity, and sensitivity. However, this project was only moderately successful as marginal cost improvements over similar tests were not achieved. Both testing methods could be easily and quickly adapted to test for other respiratory viruses in the event of a pandemic.","abstract_html":"The COVID-19 pandemic has put immense pressure on diagnostic testing infrastructure. The widely accepted reference standard laboratory testing method for COVID-19 is reverse transcriptase-PCR (RT-PCR). While highly sensitive and specific, RT-PCR tests suffer from their high cost, slow speed, and requirements for specialized instruments and technical expertise. In the community, rapid antigen tests are widely used due to their low cost, rapid speed, and ease of use. However, rapid antigen tests are hindered by their low sensitivity. The goal of this project was to help fill the gap that exists between RT-PCR tests and rapid antigen tests for COVID-19 in terms of cost, sensitivity, specificity, speed, and ease of use. To this end, two RT-LAMP tests for COVID-19 were developed. The key difference between the two tests lies in their extraction methods: one test used a silica column-based extraction method (saliva dry-LAMP) while the other test used heat-inactivated samples (direct dry-LAMP). Direct dry-LAMP was developed to improve on the shortcomings of saliva dry-LAMP. Saliva dry-LAMP was validated to near regulatory standards, while the focus was more on method optimization for the direct dry-LAMP test. For each test, a self-contained portable testing platform was developed to perform all steps of the test. The heat inactivation method in the direct dry-LAMP workflow enabled performance improvements in the areas of speed, simplicity, and sensitivity. However, this project was only moderately successful as marginal cost improvements over similar tests were not achieved. Both testing methods could be easily and quickly adapted to test for other respiratory viruses in the event of a pandemic.","abstract_has_math":false,"creators":["Toppings, Noah B"],"institution":"Cumming School of Medicine","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Medicine – Microbiology & Infectious Diseases","degree_department":null,"school":null,"contributors":[],"advisors":["Pillai, Dylan R"],"committee_chairs":[],"committee_members":["Kim, Keekyoung","De Buck, Jeroen MD","Kimura-Hara, Susana"],"year":2022,"date_issued":"2022-11-04","date_published":"2022-11-04","updated_at":"2026-11-19T07:23:51Z","subjects":["COVID-19","SARS-CoV-2","Diagnostics","RT-LAMP","LAMP","NAAT","Nucleic acid amplification test","Loop-mediated isothermal amplification","test","pandemic"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/116493"],"render_values":[{"text":"http://hdl.handle.net/1880/116493","href":"https://hdl.handle.net/1880/116493","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Toppings, N. B. (2022). Leveraging the Advances in Isothermal Nucleic Acid Amplification Technology for Point-Of- Care Diagnostics for Infectious Diseases (Master thesis). University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca ."],"render_values":[{"text":"Toppings, N. B. (2022). Leveraging the Advances in Isothermal Nucleic Acid Amplification Technology for Point-Of- Care Diagnostics for Infectious Diseases (Master thesis). University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca .","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/dspace/41337","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/dspace/41337","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":"embargoed","embargo_until":"2024-11-04","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F116493","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F116493","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Pillai, Dylan R"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kim, Keekyoung","De Buck, Jeroen MD","Kimura-Hara, Susana"]},{"key":"dc:creator","label":"Author","values":["Toppings, Noah B"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["Spring Convocation"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-05-11T06:04:56Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-11-04"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2024-11-04"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Cumming School of Medicine"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Medicine – Microbiology & Infectious Diseases"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["COVID-19","SARS-CoV-2","Diagnostics","RT-LAMP","LAMP","NAAT","Nucleic acid amplification test","Loop-mediated isothermal amplification","test","pandemic"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Health Sciences--General","Biology--Microbiology","Biology--Virology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Toppings, N. B. (2022). Leveraging the Advances in Isothermal Nucleic Acid Amplification Technology for Point-Of- Care Diagnostics for Infectious Diseases (Master thesis). University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca ."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/dspace/41337"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1880/116493"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The COVID-19 pandemic has put immense pressure on diagnostic testing infrastructure. The widely accepted reference standard laboratory testing method for COVID-19 is reverse transcriptase-PCR (RT-PCR). While highly sensitive and specific, RT-PCR tests suffer from their high cost, slow speed, and requirements for specialized instruments and technical expertise. In the community, rapid antigen tests are widely used due to their low cost, rapid speed, and ease of use. However, rapid antigen tests are hindered by their low sensitivity. The goal of this project was to help fill the gap that exists between RT-PCR tests and rapid antigen tests for COVID-19 in terms of cost, sensitivity, specificity, speed, and ease of use. To this end, two RT-LAMP tests for COVID-19 were developed. The key difference between the two tests lies in their extraction methods: one test used a silica column-based extraction method (saliva dry-LAMP) while the other test used heat-inactivated samples (direct dry-LAMP). Direct dry-LAMP was developed to improve on the shortcomings of saliva dry-LAMP. Saliva dry-LAMP was validated to near regulatory standards, while the focus was more on method optimization for the direct dry-LAMP test. For each test, a self-contained portable testing platform was developed to perform all steps of the test. The heat inactivation method in the direct dry-LAMP workflow enabled performance improvements in the areas of speed, simplicity, and sensitivity. However, this project was only moderately successful as marginal cost improvements over similar tests were not achieved. Both testing methods could be easily and quickly adapted to test for other respiratory viruses in the event of a pandemic."]},{"key":"dc:title","label":"Title","values":["Leveraging the Advances in Isothermal Nucleic Acid Amplification Technology for Point-Of- Care Diagnostics for Infectious Diseases"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Pillai, Dylan R"],"dc:contributor.committeemember":["Kim, Keekyoung","De Buck, Jeroen MD","Kimura-Hara, Susana"],"dc:creator":["Toppings, Noah B"],"dc:date":["Spring Convocation"],"dc:date.accessioned":["2023-05-11T06:04:56Z"],"dc:date.issued":["2022-11-04"],"dc:date.liftdate":["2024-11-04"],"dc:description.abstract":["The COVID-19 pandemic has put immense pressure on diagnostic testing infrastructure. The widely accepted reference standard laboratory testing method for COVID-19 is reverse transcriptase-PCR (RT-PCR). While highly sensitive and specific, RT-PCR tests suffer from their high cost, slow speed, and requirements for specialized instruments and technical expertise. In the community, rapid antigen tests are widely used due to their low cost, rapid speed, and ease of use. However, rapid antigen tests are hindered by their low sensitivity. The goal of this project was to help fill the gap that exists between RT-PCR tests and rapid antigen tests for COVID-19 in terms of cost, sensitivity, specificity, speed, and ease of use. To this end, two RT-LAMP tests for COVID-19 were developed. The key difference between the two tests lies in their extraction methods: one test used a silica column-based extraction method (saliva dry-LAMP) while the other test used heat-inactivated samples (direct dry-LAMP). Direct dry-LAMP was developed to improve on the shortcomings of saliva dry-LAMP. Saliva dry-LAMP was validated to near regulatory standards, while the focus was more on method optimization for the direct dry-LAMP test. For each test, a self-contained portable testing platform was developed to perform all steps of the test. The heat inactivation method in the direct dry-LAMP workflow enabled performance improvements in the areas of speed, simplicity, and sensitivity. However, this project was only moderately successful as marginal cost improvements over similar tests were not achieved. Both testing methods could be easily and quickly adapted to test for other respiratory viruses in the event of a pandemic."],"dc:identifier.citation":["Toppings, N. B. (2022). Leveraging the Advances in Isothermal Nucleic Acid Amplification Technology for Point-Of- Care Diagnostics for Infectious Diseases (Master thesis). University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca ."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/dspace/41337"],"dc:identifier.uri":["http://hdl.handle.net/1880/116493"],"dc:language.iso":["English"],"dc:publisher.faculty":["Cumming School of Medicine"],"dc:subject":["COVID-19","SARS-CoV-2","Diagnostics","RT-LAMP","LAMP","NAAT","Nucleic acid amplification test","Loop-mediated isothermal amplification","test","pandemic"],"dc:subject.classification":["Health Sciences--General","Biology--Microbiology","Biology--Virology"],"dc:title":["Leveraging the Advances in Isothermal Nucleic Acid Amplification Technology for Point-Of- Care Diagnostics for Infectious Diseases"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Medicine – Microbiology & Infectious Diseases"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:23:51Z"}