{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/117617"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/117617","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Validation of a novel imaging modality for knee joint space and lower limb alignment in acute knee injuries","abstract":"The anterior cruciate ligament (ACL) of the knee is one of the most frequently injured ligaments among young, athletic individuals. Previous research suggests that various anatomical factors contribute to both ACL tear incidence and predict changes in joint space width (JSW). However, investigation of simultaneous JSW with other anatomical measures tends to increase the imaging load required. Furthermore, each modality can include limitations such as small scanning region, high radiation dose, and weight-bearing tradeoffs. A recent addition to this field is bi-planar radiology (EOS Imaging) which offers simultaneous weight-bearing lateral and anterior views with novel low radiation exposure. The purpose of this study is to identify whether JSW measured by bi-planar imaging results in accurate and precise measurements of JSW. Our validation cohort of uninjured individuals (N=30, 26.7  5.1 years) underwent scanning to determine the short-term precision of the technique, involving two repeated scans per bi-planar radiograph and conventional tunnel view knee radiograph (4 scans total). The minimum apparent JSW was collected for each leg side and compartment. When the root mean square coefficient of variation (RMSCV) and least significant change (LSC) were measured, the bi-planar scans (RMSCV= 6.46%, LSC=1.07 mm) had improved or similar within scanner precision on average compared to conventional X-rays (RMSCV=7.66%, LSC=1.15 mm). When assessing the JSW accuracy by participants, there was a bias for higher JSW by bi-planar imaging than X-ray (p<0.01). Furthermore, the bi-planar standing position, performed with the left leg semi-weight-bearing, resulted in a significantly higher JSW measurement (p<0.01) in the left leg. This study emphasizes that while JSW measurements remain highly susceptible to variability, bi-planar scanners are highly reproducible. While radiography remains accessible clinically, accurate and precise JSW by bi-planar scanners is feasible provided knee position and alignment controlled.","abstract_html":"The anterior cruciate ligament (ACL) of the knee is one of the most frequently injured ligaments among young, athletic individuals. Previous research suggests that various anatomical factors contribute to both ACL tear incidence and predict changes in joint space width (JSW). However, investigation of simultaneous JSW with other anatomical measures tends to increase the imaging load required. Furthermore, each modality can include limitations such as small scanning region, high radiation dose, and weight-bearing tradeoffs. A recent addition to this field is bi-planar radiology (EOS Imaging) which offers simultaneous weight-bearing lateral and anterior views with novel low radiation exposure. The purpose of this study is to identify whether JSW measured by bi-planar imaging results in accurate and precise measurements of JSW. Our validation cohort of uninjured individuals (N=30, 26.7  5.1 years) underwent scanning to determine the short-term precision of the technique, involving two repeated scans per bi-planar radiograph and conventional tunnel view knee radiograph (4 scans total). The minimum apparent JSW was collected for each leg side and compartment. When the root mean square coefficient of variation (RMSCV) and least significant change (LSC) were measured, the bi-planar scans (RMSCV= 6.46%, LSC=1.07 mm) had improved or similar within scanner precision on average compared to conventional X-rays (RMSCV=7.66%, LSC=1.15 mm). When assessing the JSW accuracy by participants, there was a bias for higher JSW by bi-planar imaging than X-ray (p&lt;0.01). Furthermore, the bi-planar standing position, performed with the left leg semi-weight-bearing, resulted in a significantly higher JSW measurement (p&lt;0.01) in the left leg. This study emphasizes that while JSW measurements remain highly susceptible to variability, bi-planar scanners are highly reproducible. While radiography remains accessible clinically, accurate and precise JSW by bi-planar scanners is feasible provided knee position and alignment controlled.","abstract_has_math":false,"creators":["Vandergaag, Isabella Derij"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Engineering – Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":["Boyd, Steven"],"committee_chairs":[],"committee_members":["Walker, Richard","Manocha, Ranita","Edwards, Brent"],"year":2023,"date_issued":"2023-12-04","date_published":"2023-12-04","updated_at":"2026-11-19T07:29:47Z","subjects":["Bi-planar radiography","joint space width","Osteoarthritis","Radiation","Knee"],"languages":["en"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/117617"],"render_values":[{"text":"https://hdl.handle.net/1880/117617","href":"https://hdl.handle.net/1880/117617","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Vandergaag, I. D. (2023). Validation of a novel imaging modality for knee joint space and lower limb alignment in acute knee injuries (Master's/Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Vandergaag, I. D. (2023). Validation of a novel imaging modality for knee joint space and lower limb alignment in acute knee injuries (Master's/Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/42460","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/42460","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F117617","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F117617","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Boyd, Steven"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Walker, Richard","Manocha, Ranita","Edwards, Brent"]},{"key":"dc:creator","label":"Author","values":["Vandergaag, Isabella Derij"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-02"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-12-05T16:49:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-12-05T16:49:14Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-12-04"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering – Biomedical"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:release_request","label":"Thesis Release Request","values":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bi-planar radiography","joint space width","Osteoarthritis","Radiation","Knee"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Engineering--Biomedical","Radiology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Vandergaag, I. D. (2023). Validation of a novel imaging modality for knee joint space and lower limb alignment in acute knee injuries (Master's/Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.11575/PRISM/42460"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/117617"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The anterior cruciate ligament (ACL) of the knee is one of the most frequently injured ligaments among young, athletic individuals. Previous research suggests that various anatomical factors contribute to both ACL tear incidence and predict changes in joint space width (JSW). However, investigation of simultaneous JSW with other anatomical measures tends to increase the imaging load required. Furthermore, each modality can include limitations such as small scanning region, high radiation dose, and weight-bearing tradeoffs. A recent addition to this field is bi-planar radiology (EOS Imaging) which offers simultaneous weight-bearing lateral and anterior views with novel low radiation exposure. The purpose of this study is to identify whether JSW measured by bi-planar imaging results in accurate and precise measurements of JSW. Our validation cohort of uninjured individuals (N=30, 26.7  5.1 years) underwent scanning to determine the short-term precision of the technique, involving two repeated scans per bi-planar radiograph and conventional tunnel view knee radiograph (4 scans total). The minimum apparent JSW was collected for each leg side and compartment. When the root mean square coefficient of variation (RMSCV) and least significant change (LSC) were measured, the bi-planar scans (RMSCV= 6.46%, LSC=1.07 mm) had improved or similar within scanner precision on average compared to conventional X-rays (RMSCV=7.66%, LSC=1.15 mm). When assessing the JSW accuracy by participants, there was a bias for higher JSW by bi-planar imaging than X-ray (p<0.01). Furthermore, the bi-planar standing position, performed with the left leg semi-weight-bearing, resulted in a significantly higher JSW measurement (p<0.01) in the left leg. This study emphasizes that while JSW measurements remain highly susceptible to variability, bi-planar scanners are highly reproducible. While radiography remains accessible clinically, accurate and precise JSW by bi-planar scanners is feasible provided knee position and alignment controlled."]},{"key":"dc:title","label":"Title","values":["Validation of a novel imaging modality for knee joint space and lower limb alignment in acute knee injuries"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Boyd, Steven"],"dc:contributor.committeemember":["Walker, Richard","Manocha, Ranita","Edwards, Brent"],"dc:creator":["Vandergaag, Isabella Derij"],"dc:date":["2024-02"],"dc:date.accessioned":["2023-12-05T16:49:14Z"],"dc:date.available":["2023-12-05T16:49:14Z"],"dc:date.issued":["2023-12-04"],"dc:description.abstract":["The anterior cruciate ligament (ACL) of the knee is one of the most frequently injured ligaments among young, athletic individuals. Previous research suggests that various anatomical factors contribute to both ACL tear incidence and predict changes in joint space width (JSW). However, investigation of simultaneous JSW with other anatomical measures tends to increase the imaging load required. Furthermore, each modality can include limitations such as small scanning region, high radiation dose, and weight-bearing tradeoffs. A recent addition to this field is bi-planar radiology (EOS Imaging) which offers simultaneous weight-bearing lateral and anterior views with novel low radiation exposure. The purpose of this study is to identify whether JSW measured by bi-planar imaging results in accurate and precise measurements of JSW. Our validation cohort of uninjured individuals (N=30, 26.7  5.1 years) underwent scanning to determine the short-term precision of the technique, involving two repeated scans per bi-planar radiograph and conventional tunnel view knee radiograph (4 scans total). The minimum apparent JSW was collected for each leg side and compartment. When the root mean square coefficient of variation (RMSCV) and least significant change (LSC) were measured, the bi-planar scans (RMSCV= 6.46%, LSC=1.07 mm) had improved or similar within scanner precision on average compared to conventional X-rays (RMSCV=7.66%, LSC=1.15 mm). When assessing the JSW accuracy by participants, there was a bias for higher JSW by bi-planar imaging than X-ray (p<0.01). Furthermore, the bi-planar standing position, performed with the left leg semi-weight-bearing, resulted in a significantly higher JSW measurement (p<0.01) in the left leg. This study emphasizes that while JSW measurements remain highly susceptible to variability, bi-planar scanners are highly reproducible. While radiography remains accessible clinically, accurate and precise JSW by bi-planar scanners is feasible provided knee position and alignment controlled."],"dc:identifier.citation":["Vandergaag, I. D. (2023). Validation of a novel imaging modality for knee joint space and lower limb alignment in acute knee injuries (Master's/Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["https://doi.org/10.11575/PRISM/42460"],"dc:identifier.uri":["https://hdl.handle.net/1880/117617"],"dc:language.iso":["en"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Bi-planar radiography","joint space width","Osteoarthritis","Radiation","Knee"],"dc:subject.classification":["Engineering--Biomedical","Radiology"],"dc:title":["Validation of a novel imaging modality for knee joint space and lower limb alignment in acute knee injuries"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering – Biomedical"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"],"thesis:release_request":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]},"updated_at":"2026-11-19T07:29:47Z"}