{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/117885"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/117885","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Monte Carlo Studies in the Applications of Magnetic Fields to Electron Radiotherapy","abstract":"In electron radiation therapy, conforming the radiation dose to the tumor is important, yet challenging due to electron scatter by air molecules. The conventional approach involves placing a fixed metal collimator near the patient’s skin to block scattered radiation, providing a static treatment. This study explores the dosimetric impact of magnetic fields on therapeutic electron beams and the potential application of magnetic fields in modulated electron radiation therapy (MERT). Employing Monte Carlo methods, we developed experimentally validated source models with electron beams shaped by the multileaf collimator. Additionally, we calculated magnetic field maps for specific coil configurations and devised a method to implement non-uniform magnetic fields into PENELOPE, a Monte Carlo code system for radiation transport. Our approach facilitates easy evaluation of different coil-generated magnetic fields. Our framework was used to study the impact of magnetic fields generated by solenoids on realistic electron beams. This showed that while simplistic simulations using uniform magnetic fields and mono-directional electron sources show promising results, simulations with realistic electron beams and the magnetic field generated by a solenoid reveal the complexities involved in maintaining electron fluence within realistic magnetic fields. Overall, this work lays the foundation for potential advancements in the application of magnetic fields in electron radiation therapy, underscoring the importance of accurate simulations when exploring innovative treatment modalities.","abstract_html":"In electron radiation therapy, conforming the radiation dose to the tumor is important, yet challenging due to electron scatter by air molecules. The conventional approach involves placing a fixed metal collimator near the patient’s skin to block scattered radiation, providing a static treatment. This study explores the dosimetric impact of magnetic fields on therapeutic electron beams and the potential application of magnetic fields in modulated electron radiation therapy (MERT). Employing Monte Carlo methods, we developed experimentally validated source models with electron beams shaped by the multileaf collimator. Additionally, we calculated magnetic field maps for specific coil configurations and devised a method to implement non-uniform magnetic fields into PENELOPE, a Monte Carlo code system for radiation transport. Our approach facilitates easy evaluation of different coil-generated magnetic fields. Our framework was used to study the impact of magnetic fields generated by solenoids on realistic electron beams. This showed that while simplistic simulations using uniform magnetic fields and mono-directional electron sources show promising results, simulations with realistic electron beams and the magnetic field generated by a solenoid reveal the complexities involved in maintaining electron fluence within realistic magnetic fields. Overall, this work lays the foundation for potential advancements in the application of magnetic fields in electron radiation therapy, underscoring the importance of accurate simulations when exploring innovative treatment modalities.","abstract_has_math":false,"creators":["Groeneveld, Jacob"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Physics & Astronomy","degree_department":null,"school":null,"contributors":[],"advisors":["Kirkby, Charles"],"committee_chairs":[],"committee_members":["Yau, Andrew","Shaw, Conor","McGeachy, Philip"],"year":2024,"date_issued":"2024-01-04","date_published":"2024-01-04","updated_at":"2026-11-19T07:13:50Z","subjects":["Monte Carlo","Non-Uniform Magnetic Fields","PENELOPE","Radiation Therapy","Electron Radation Therapy","Electron Source Model","Magnetic Collimation"],"languages":["en"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/117885"],"render_values":[{"text":"https://hdl.handle.net/1880/117885","href":"https://hdl.handle.net/1880/117885","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Groeneveld, J. (2024). Monte Carlo studies in the applications of magnetic fields to electron radiotherapy (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Groeneveld, J. (2024). Monte Carlo studies in the applications of magnetic fields to electron radiotherapy (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/42728","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/42728","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F117885","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F117885","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kirkby, Charles"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Yau, Andrew","Shaw, Conor","McGeachy, Philip"]},{"key":"dc:creator","label":"Author","values":["Groeneveld, Jacob"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-05"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-01-05T23:14:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-01-05T23:14:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2024-01-04"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics & Astronomy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:release_request","label":"Thesis Release Request","values":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Monte Carlo","Non-Uniform Magnetic Fields","PENELOPE","Radiation Therapy","Electron Radation Therapy","Electron Source Model","Magnetic Collimation"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Electricity and Magnetism","Elementary Particles and High Energy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Groeneveld, J. (2024). Monte Carlo studies in the applications of magnetic fields to electron radiotherapy (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.11575/PRISM/42728"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/117885"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In electron radiation therapy, conforming the radiation dose to the tumor is important, yet challenging due to electron scatter by air molecules. The conventional approach involves placing a fixed metal collimator near the patient’s skin to block scattered radiation, providing a static treatment. This study explores the dosimetric impact of magnetic fields on therapeutic electron beams and the potential application of magnetic fields in modulated electron radiation therapy (MERT). Employing Monte Carlo methods, we developed experimentally validated source models with electron beams shaped by the multileaf collimator. Additionally, we calculated magnetic field maps for specific coil configurations and devised a method to implement non-uniform magnetic fields into PENELOPE, a Monte Carlo code system for radiation transport. Our approach facilitates easy evaluation of different coil-generated magnetic fields. Our framework was used to study the impact of magnetic fields generated by solenoids on realistic electron beams. This showed that while simplistic simulations using uniform magnetic fields and mono-directional electron sources show promising results, simulations with realistic electron beams and the magnetic field generated by a solenoid reveal the complexities involved in maintaining electron fluence within realistic magnetic fields. Overall, this work lays the foundation for potential advancements in the application of magnetic fields in electron radiation therapy, underscoring the importance of accurate simulations when exploring innovative treatment modalities."]},{"key":"dc:title","label":"Title","values":["Monte Carlo Studies in the Applications of Magnetic Fields to Electron Radiotherapy"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kirkby, Charles"],"dc:contributor.committeemember":["Yau, Andrew","Shaw, Conor","McGeachy, Philip"],"dc:creator":["Groeneveld, Jacob"],"dc:date":["2024-05"],"dc:date.accessioned":["2024-01-05T23:14:19Z"],"dc:date.available":["2024-01-05T23:14:19Z"],"dc:date.issued":["2024-01-04"],"dc:description.abstract":["In electron radiation therapy, conforming the radiation dose to the tumor is important, yet challenging due to electron scatter by air molecules. The conventional approach involves placing a fixed metal collimator near the patient’s skin to block scattered radiation, providing a static treatment. This study explores the dosimetric impact of magnetic fields on therapeutic electron beams and the potential application of magnetic fields in modulated electron radiation therapy (MERT). Employing Monte Carlo methods, we developed experimentally validated source models with electron beams shaped by the multileaf collimator. Additionally, we calculated magnetic field maps for specific coil configurations and devised a method to implement non-uniform magnetic fields into PENELOPE, a Monte Carlo code system for radiation transport. Our approach facilitates easy evaluation of different coil-generated magnetic fields. Our framework was used to study the impact of magnetic fields generated by solenoids on realistic electron beams. This showed that while simplistic simulations using uniform magnetic fields and mono-directional electron sources show promising results, simulations with realistic electron beams and the magnetic field generated by a solenoid reveal the complexities involved in maintaining electron fluence within realistic magnetic fields. Overall, this work lays the foundation for potential advancements in the application of magnetic fields in electron radiation therapy, underscoring the importance of accurate simulations when exploring innovative treatment modalities."],"dc:identifier.citation":["Groeneveld, J. (2024). Monte Carlo studies in the applications of magnetic fields to electron radiotherapy (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["https://doi.org/10.11575/PRISM/42728"],"dc:identifier.uri":["https://hdl.handle.net/1880/117885"],"dc:language.iso":["en"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Monte Carlo","Non-Uniform Magnetic Fields","PENELOPE","Radiation Therapy","Electron Radation Therapy","Electron Source Model","Magnetic Collimation"],"dc:subject.classification":["Electricity and Magnetism","Elementary Particles and High Energy"],"dc:title":["Monte Carlo Studies in the Applications of Magnetic Fields to Electron Radiotherapy"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics & Astronomy"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"],"thesis:release_request":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]},"updated_at":"2026-11-19T07:13:50Z"}