{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/119522"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/119522","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Improvement of Spray Column Performance for Post-Combustion Carbon Dioxide Capture using different Column Configurations","abstract":"Amine absorption process is recognized as the most mature technology available today for post-combustion CO2 capture. The absorption process is generally carried out in a packed bed absorber where flue gas and solvent are brought into intimate contact for mass transfer. However, this type of contractor suffers from limitations such as low gas handling capacity, significant pressure drop and expensive internals which has necessitated the search for a better alternative. Based on the findings from literature, a spray column is seen to be a promising alternative, however, needs further design improvements to achieve a comparable gas-liquid contact efficiency. Recent work in this field indicates that for a spray column, the mass transfer coefficient is highest in zones near the spray nozzle (spray zone), and it is expected that increasing the number of spray zones will enhance the column performance. This finding formed the basis of my research where experimental investigation into the performance improvement of spray column using three distinctive design configuration was carried out in a laboratory scale glass column of 1.1 m height and 0.2 m internal diameter. The base case design consisted of single spray nozzle at the column top while the second and the third configurations consisted of two spray nozzles, one nozzle at the top and the second nozzle at the middle section with equal flow distribution. The results obtained from this work indicate that there is a substantial step change in terms of CO2 absorption as the gas moves closer to the nozzle, validating the understanding that mass transfer coefficient is higher in the spray zone. Further, increasing the number of spray zones in the column with configuration 2 and configuration 3, the performance of the column was improved significantly with an increase in absorption efficiency by up to 10% for configuration 3 as compared to the base configuration. Overall, the experimental investigation carried out as part of this research work shows that spray column performance can be improved with a design that incorporates more spray zones in the column and can potentially achieve removal efficiencies that makes it a promising alternative to the conventionally used packed columns.","abstract_html":"Amine absorption process is recognized as the most mature technology available today for post-combustion CO2 capture. The absorption process is generally carried out in a packed bed absorber where flue gas and solvent are brought into intimate contact for mass transfer. However, this type of contractor suffers from limitations such as low gas handling capacity, significant pressure drop and expensive internals which has necessitated the search for a better alternative. Based on the findings from literature, a spray column is seen to be a promising alternative, however, needs further design improvements to achieve a comparable gas-liquid contact efficiency. Recent work in this field indicates that for a spray column, the mass transfer coefficient is highest in zones near the spray nozzle (spray zone), and it is expected that increasing the number of spray zones will enhance the column performance. This finding formed the basis of my research where experimental investigation into the performance improvement of spray column using three distinctive design configuration was carried out in a laboratory scale glass column of 1.1 m height and 0.2 m internal diameter. The base case design consisted of single spray nozzle at the column top while the second and the third configurations consisted of two spray nozzles, one nozzle at the top and the second nozzle at the middle section with equal flow distribution. The results obtained from this work indicate that there is a substantial step change in terms of CO2 absorption as the gas moves closer to the nozzle, validating the understanding that mass transfer coefficient is higher in the spray zone. Further, increasing the number of spray zones in the column with configuration 2 and configuration 3, the performance of the column was improved significantly with an increase in absorption efficiency by up to 10% for configuration 3 as compared to the base configuration. Overall, the experimental investigation carried out as part of this research work shows that spray column performance can be improved with a design that incorporates more spray zones in the column and can potentially achieve removal efficiencies that makes it a promising alternative to the conventionally used packed columns.","abstract_has_math":false,"creators":["Dave, Maharshi Rohitkumar"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Engineering – Chemical & Petroleum","degree_department":null,"school":null,"contributors":[],"advisors":["Mahinpey, Nader"],"committee_chairs":[],"committee_members":["Hassanzadeh, Hassan","Sumon, Kazi Z"],"year":2024,"date_issued":"2024-08-20","date_published":"2024-08-20","updated_at":"2026-11-19T07:37:07Z","subjects":["Spray Column","Multiple Spray Nozzles","Carbon Capture","Amine Absorption Process"],"languages":["en"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/119522"],"render_values":[{"text":"https://hdl.handle.net/1880/119522","href":"https://hdl.handle.net/1880/119522","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Dave, M. R. (2024). Improvement of spray column performance for post-combustion carbon dioxide capture using different column configurations (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Dave, M. R. (2024). Improvement of spray column performance for post-combustion carbon dioxide capture using different column configurations (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/47133","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/47133","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F119522","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F119522","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mahinpey, Nader"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hassanzadeh, Hassan","Sumon, Kazi Z"]},{"key":"dc:creator","label":"Author","values":["Dave, Maharshi Rohitkumar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-08-27T18:45:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-27T18:45:30Z"]},{"key":"dc:date.issued","label":"Date","values":["2024-08-20"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering – Chemical & Petroleum"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:release_request","label":"Thesis Release Request","values":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Spray Column","Multiple Spray Nozzles","Carbon Capture","Amine Absorption Process"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Engineering--Chemical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Dave, M. R. (2024). Improvement of spray column performance for post-combustion carbon dioxide capture using different column configurations (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/47133"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/119522"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Amine absorption process is recognized as the most mature technology available today for post-combustion CO2 capture. The absorption process is generally carried out in a packed bed absorber where flue gas and solvent are brought into intimate contact for mass transfer. However, this type of contractor suffers from limitations such as low gas handling capacity, significant pressure drop and expensive internals which has necessitated the search for a better alternative. Based on the findings from literature, a spray column is seen to be a promising alternative, however, needs further design improvements to achieve a comparable gas-liquid contact efficiency. Recent work in this field indicates that for a spray column, the mass transfer coefficient is highest in zones near the spray nozzle (spray zone), and it is expected that increasing the number of spray zones will enhance the column performance. This finding formed the basis of my research where experimental investigation into the performance improvement of spray column using three distinctive design configuration was carried out in a laboratory scale glass column of 1.1 m height and 0.2 m internal diameter. The base case design consisted of single spray nozzle at the column top while the second and the third configurations consisted of two spray nozzles, one nozzle at the top and the second nozzle at the middle section with equal flow distribution. The results obtained from this work indicate that there is a substantial step change in terms of CO2 absorption as the gas moves closer to the nozzle, validating the understanding that mass transfer coefficient is higher in the spray zone. Further, increasing the number of spray zones in the column with configuration 2 and configuration 3, the performance of the column was improved significantly with an increase in absorption efficiency by up to 10% for configuration 3 as compared to the base configuration. Overall, the experimental investigation carried out as part of this research work shows that spray column performance can be improved with a design that incorporates more spray zones in the column and can potentially achieve removal efficiencies that makes it a promising alternative to the conventionally used packed columns."]},{"key":"dc:title","label":"Title","values":["Improvement of Spray Column Performance for Post-Combustion Carbon Dioxide Capture using different Column Configurations"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mahinpey, Nader"],"dc:contributor.committeemember":["Hassanzadeh, Hassan","Sumon, Kazi Z"],"dc:creator":["Dave, Maharshi Rohitkumar"],"dc:date":["2024-11"],"dc:date.accessioned":["2024-08-27T18:45:30Z"],"dc:date.available":["2024-08-27T18:45:30Z"],"dc:date.issued":["2024-08-20"],"dc:description.abstract":["Amine absorption process is recognized as the most mature technology available today for post-combustion CO2 capture. The absorption process is generally carried out in a packed bed absorber where flue gas and solvent are brought into intimate contact for mass transfer. However, this type of contractor suffers from limitations such as low gas handling capacity, significant pressure drop and expensive internals which has necessitated the search for a better alternative. Based on the findings from literature, a spray column is seen to be a promising alternative, however, needs further design improvements to achieve a comparable gas-liquid contact efficiency. Recent work in this field indicates that for a spray column, the mass transfer coefficient is highest in zones near the spray nozzle (spray zone), and it is expected that increasing the number of spray zones will enhance the column performance. This finding formed the basis of my research where experimental investigation into the performance improvement of spray column using three distinctive design configuration was carried out in a laboratory scale glass column of 1.1 m height and 0.2 m internal diameter. The base case design consisted of single spray nozzle at the column top while the second and the third configurations consisted of two spray nozzles, one nozzle at the top and the second nozzle at the middle section with equal flow distribution. The results obtained from this work indicate that there is a substantial step change in terms of CO2 absorption as the gas moves closer to the nozzle, validating the understanding that mass transfer coefficient is higher in the spray zone. Further, increasing the number of spray zones in the column with configuration 2 and configuration 3, the performance of the column was improved significantly with an increase in absorption efficiency by up to 10% for configuration 3 as compared to the base configuration. Overall, the experimental investigation carried out as part of this research work shows that spray column performance can be improved with a design that incorporates more spray zones in the column and can potentially achieve removal efficiencies that makes it a promising alternative to the conventionally used packed columns."],"dc:identifier.citation":["Dave, M. R. (2024). Improvement of spray column performance for post-combustion carbon dioxide capture using different column configurations (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/47133"],"dc:identifier.uri":["https://hdl.handle.net/1880/119522"],"dc:language.iso":["en"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Spray Column","Multiple Spray Nozzles","Carbon Capture","Amine Absorption Process"],"dc:subject.classification":["Engineering--Chemical"],"dc:title":["Improvement of Spray Column Performance for Post-Combustion Carbon Dioxide Capture using different Column Configurations"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering – Chemical & Petroleum"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"],"thesis:release_request":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]},"updated_at":"2026-11-19T07:37:07Z"}