{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/121050"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/121050","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Computed Tomography–Based Finite Element Modeling of the Rabbit Hindlimb","abstract":"Animal models are an essential pillar of orthopaedic research. Rodents, in particular, have played a pivotal role in developing our current understanding of bone mechanobiology, but they lack the Haversian systems found in human bone. For studies of mechanobiology and in line with FDA recommendations, researchers are turning to larger animal models, like rabbits, which naturally exhibit intracortical remodeling. Our group has developed a non–invasive, in vivo rabbit tibial loading model to establish the relationships between applied load, strains, microdamage accumulation, and bone remodeling. To capture the strain environment, we require a validated computed tomography (CT)–based finite element (FE) model of the rabbit hindlimb. To this end, we first established the density–elasticity relationships for rabbit hindlimb bones. By using well defined experimental boundary conditions for in silico replication, we were able to optimize the density–elasticity power law constants such that the resulting FE models provided strain predictions that were strongly correlated with experimental measurements (0.85 ≤ R2 ≤ 0.96). With the ability to accurately assign heterogeneous material properties, the derived relationships were used in CT–based FE models of the rabbit hindlimb. Early findings revealed that FE strain predictions were exceptionally sensitive to the assumed force vector orientation, and increasing the model complexity would be futile. Instead, we developed an experimentally informed optimization approach to determine the individual force vector orientations that minimized the error between FE predicted and experimentally measured bone strains. This resulted in statically equivalent FE models that explained up to 96% of the variation in experimental strain mesurements. Our work serves to guide future in vivo rabbit hindlimb loading studies and enable the use of computational models in the investigation of bone mechanobiology.","abstract_html":"Animal models are an essential pillar of orthopaedic research. Rodents, in particular, have played a pivotal role in developing our current understanding of bone mechanobiology, but they lack the Haversian systems found in human bone. For studies of mechanobiology and in line with FDA recommendations, researchers are turning to larger animal models, like rabbits, which naturally exhibit intracortical remodeling. Our group has developed a non–invasive, in vivo rabbit tibial loading model to establish the relationships between applied load, strains, microdamage accumulation, and bone remodeling. To capture the strain environment, we require a validated computed tomography (CT)–based finite element (FE) model of the rabbit hindlimb. To this end, we first established the density–elasticity relationships for rabbit hindlimb bones. By using well defined experimental boundary conditions for in silico replication, we were able to optimize the density–elasticity power law constants such that the resulting FE models provided strain predictions that were strongly correlated with experimental measurements (0.85 ≤ R2 ≤ 0.96). With the ability to accurately assign heterogeneous material properties, the derived relationships were used in CT–based FE models of the rabbit hindlimb. Early findings revealed that FE strain predictions were exceptionally sensitive to the assumed force vector orientation, and increasing the model complexity would be futile. Instead, we developed an experimentally informed optimization approach to determine the individual force vector orientations that minimized the error between FE predicted and experimentally measured bone strains. This resulted in statically equivalent FE models that explained up to 96% of the variation in experimental strain mesurements. Our work serves to guide future in vivo rabbit hindlimb loading studies and enable the use of computational models in the investigation of bone mechanobiology.","abstract_has_math":false,"creators":["Dimnik, Jonah M."],"institution":"Kinesiology","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Kinesiology","degree_department":null,"school":null,"contributors":[],"advisors":["Edwards, W. Brent"],"committee_chairs":[],"committee_members":["Boyd, Steven K.","Whittier, Danielle E. W."],"year":2025,"date_issued":"2025-04-22","date_published":"2025-04-22","updated_at":"2026-11-19T07:13:28Z","subjects":[],"languages":["en"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/121050"],"render_values":[{"text":"https://hdl.handle.net/1880/121050","href":"https://hdl.handle.net/1880/121050","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Dimnik, J. (2025). Computed tomography–based finite element modeling of the rabbit hindlimb (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Dimnik, J. (2025). Computed tomography–based finite element modeling of the rabbit hindlimb (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/48640","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/48640","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F121050","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F121050","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Edwards, W. Brent"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Boyd, Steven K.","Whittier, Danielle E. W."]},{"key":"dc:creator","label":"Author","values":["Dimnik, Jonah M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-06-09"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-22T21:33:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-22T21:33:01Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-04-22"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Kinesiology"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Kinesiology"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:release_request","label":"Thesis Release Request","values":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Engineering--Biomedical","Applied Mechanics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Dimnik, J. (2025). Computed tomography–based finite element modeling of the rabbit hindlimb (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/48640"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/121050"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Animal models are an essential pillar of orthopaedic research. Rodents, in particular, have played a pivotal role in developing our current understanding of bone mechanobiology, but they lack the Haversian systems found in human bone. For studies of mechanobiology and in line with FDA recommendations, researchers are turning to larger animal models, like rabbits, which naturally exhibit intracortical remodeling. Our group has developed a non–invasive, in vivo rabbit tibial loading model to establish the relationships between applied load, strains, microdamage accumulation, and bone remodeling. To capture the strain environment, we require a validated computed tomography (CT)–based finite element (FE) model of the rabbit hindlimb. To this end, we first established the density–elasticity relationships for rabbit hindlimb bones. By using well defined experimental boundary conditions for in silico replication, we were able to optimize the density–elasticity power law constants such that the resulting FE models provided strain predictions that were strongly correlated with experimental measurements (0.85 ≤ R2 ≤ 0.96). With the ability to accurately assign heterogeneous material properties, the derived relationships were used in CT–based FE models of the rabbit hindlimb. Early findings revealed that FE strain predictions were exceptionally sensitive to the assumed force vector orientation, and increasing the model complexity would be futile. Instead, we developed an experimentally informed optimization approach to determine the individual force vector orientations that minimized the error between FE predicted and experimentally measured bone strains. This resulted in statically equivalent FE models that explained up to 96% of the variation in experimental strain mesurements. Our work serves to guide future in vivo rabbit hindlimb loading studies and enable the use of computational models in the investigation of bone mechanobiology."]},{"key":"dc:title","label":"Title","values":["Computed Tomography–Based Finite Element Modeling of the Rabbit Hindlimb"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Edwards, W. Brent"],"dc:contributor.committeemember":["Boyd, Steven K.","Whittier, Danielle E. W."],"dc:creator":["Dimnik, Jonah M."],"dc:date":["2025-06-09"],"dc:date.accessioned":["2025-04-22T21:33:01Z"],"dc:date.available":["2025-04-22T21:33:01Z"],"dc:date.issued":["2025-04-22"],"dc:description.abstract":["Animal models are an essential pillar of orthopaedic research. Rodents, in particular, have played a pivotal role in developing our current understanding of bone mechanobiology, but they lack the Haversian systems found in human bone. For studies of mechanobiology and in line with FDA recommendations, researchers are turning to larger animal models, like rabbits, which naturally exhibit intracortical remodeling. Our group has developed a non–invasive, in vivo rabbit tibial loading model to establish the relationships between applied load, strains, microdamage accumulation, and bone remodeling. To capture the strain environment, we require a validated computed tomography (CT)–based finite element (FE) model of the rabbit hindlimb. To this end, we first established the density–elasticity relationships for rabbit hindlimb bones. By using well defined experimental boundary conditions for in silico replication, we were able to optimize the density–elasticity power law constants such that the resulting FE models provided strain predictions that were strongly correlated with experimental measurements (0.85 ≤ R2 ≤ 0.96). With the ability to accurately assign heterogeneous material properties, the derived relationships were used in CT–based FE models of the rabbit hindlimb. Early findings revealed that FE strain predictions were exceptionally sensitive to the assumed force vector orientation, and increasing the model complexity would be futile. Instead, we developed an experimentally informed optimization approach to determine the individual force vector orientations that minimized the error between FE predicted and experimentally measured bone strains. This resulted in statically equivalent FE models that explained up to 96% of the variation in experimental strain mesurements. Our work serves to guide future in vivo rabbit hindlimb loading studies and enable the use of computational models in the investigation of bone mechanobiology."],"dc:identifier.citation":["Dimnik, J. (2025). Computed tomography–based finite element modeling of the rabbit hindlimb (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/48640"],"dc:identifier.uri":["https://hdl.handle.net/1880/121050"],"dc:language.iso":["en"],"dc:publisher.faculty":["Kinesiology"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject.classification":["Engineering--Biomedical","Applied Mechanics"],"dc:title":["Computed Tomography–Based Finite Element Modeling of the Rabbit Hindlimb"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Kinesiology"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"],"thesis:release_request":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]},"updated_at":"2026-11-19T07:13:28Z"}