{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/121176"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/121176","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"High-temperature Sulfidic Attack on Carbon Steel and Select Alloys","abstract":"In the oil and gas industry, H2S is a prevalent compound that arises from various geological processes (i.e., thermal and microbial sulfate reduction) and is also generated during some upgrading operations (i.e., hydrotreating). As such, immense efforts are taken not to release H2S into the environment during the exploitation of natural resources. In this context, the modified Claus process is the most widely used technology in sulfur recovery, whereby, across multiple thermal and catalytic stages, H2S gas is converted to elemental sulfur. While this is a mature technology, the waste heat boiler after the thermal reactor in the modified Claus process has a finite life. This is due to a corrosion phenomenon referred to as high-temperature sulfidic attack on the metal tubes providing thermal transfer from process gas to water/stream. However, there is a scarcity of kinetic models which can be used to predict corrosion rates under the aforementioned conditions, and the existing models are known to be unreliable. This research focuses on optimizing the method that is used to obtain steady-state corrosion rates. A custom-built furnace apparatus was used for these studies, and carbon steel coupons (ASTM A36) were used as the test material in the initial stages of this research. However, the use of coupons was discontinued and replaced by smaller metal spheres to increase accessible surface area. H2S concentrations ranging from 10 – 20 mol% were investigated, and some initial experiments probing the effect of H2O were also performed. Weight loss measurements using carbon steel spheres yielded a corrosion rate of 6.0 ± 0.3 mpy, while weight gain measurements (assuming FeS1.5) resulted in 5.1 ± 0.1 mpy. However, calculating the corrosion rate assuming FeS1.3 produced 5.9 ± 0.2 mpy, which is consistent with the weight loss method. In addition, preliminary thermogravimetric analyzer (TGA) investigations were conducted utilizing carbon steel spheres with a 20 mol% H2S feed gas stream. Combined with a comparison of the techniques, the TGA method shows promise for future experiments. Finally, the compositions of the resultant corrosion scales were studied using grazing incidence X-ray diffraction (GIXRD).","abstract_html":"In the oil and gas industry, H2S is a prevalent compound that arises from various geological processes (i.e., thermal and microbial sulfate reduction) and is also generated during some upgrading operations (i.e., hydrotreating). As such, immense efforts are taken not to release H2S into the environment during the exploitation of natural resources. In this context, the modified Claus process is the most widely used technology in sulfur recovery, whereby, across multiple thermal and catalytic stages, H2S gas is converted to elemental sulfur. While this is a mature technology, the waste heat boiler after the thermal reactor in the modified Claus process has a finite life. This is due to a corrosion phenomenon referred to as high-temperature sulfidic attack on the metal tubes providing thermal transfer from process gas to water/stream. However, there is a scarcity of kinetic models which can be used to predict corrosion rates under the aforementioned conditions, and the existing models are known to be unreliable. This research focuses on optimizing the method that is used to obtain steady-state corrosion rates. A custom-built furnace apparatus was used for these studies, and carbon steel coupons (ASTM A36) were used as the test material in the initial stages of this research. However, the use of coupons was discontinued and replaced by smaller metal spheres to increase accessible surface area. H2S concentrations ranging from 10 – 20 mol% were investigated, and some initial experiments probing the effect of H2O were also performed. Weight loss measurements using carbon steel spheres yielded a corrosion rate of 6.0 ± 0.3 mpy, while weight gain measurements (assuming FeS1.5) resulted in 5.1 ± 0.1 mpy. However, calculating the corrosion rate assuming FeS1.3 produced 5.9 ± 0.2 mpy, which is consistent with the weight loss method. In addition, preliminary thermogravimetric analyzer (TGA) investigations were conducted utilizing carbon steel spheres with a 20 mol% H2S feed gas stream. Combined with a comparison of the techniques, the TGA method shows promise for future experiments. Finally, the compositions of the resultant corrosion scales were studied using grazing incidence X-ray diffraction (GIXRD).","abstract_has_math":false,"creators":["Gunarathna, Madushan Dhammika"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":["Marriott, Robert A."],"committee_chairs":[],"committee_members":["Birss, Viola Ingrid","Trudel, Simon","Shimizu, George Kisa Hayashi","Salahub, Dennis R."],"year":2025,"date_issued":"2025-04-28","date_published":"2025-04-28","updated_at":"2026-11-19T07:37:07Z","subjects":[],"languages":["en"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/121176"],"render_values":[{"text":"https://hdl.handle.net/1880/121176","href":"https://hdl.handle.net/1880/121176","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Gunarathna, M. D. (2025). High-temperature sulfidic attack on carbon steel and select alloys (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Gunarathna, M. D. (2025). High-temperature sulfidic attack on carbon steel and select alloys (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/48766","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/48766","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F121176","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F121176","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marriott, Robert A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Birss, Viola Ingrid","Trudel, Simon","Shimizu, George Kisa Hayashi","Salahub, Dennis R."]},{"key":"dc:creator","label":"Author","values":["Gunarathna, Madushan Dhammika"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-06"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-29T21:57:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-29T21:57:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-04-28"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:release_request","label":"Thesis Release Request","values":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Chemistry--Physical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Gunarathna, M. D. (2025). High-temperature sulfidic attack on carbon steel and select alloys (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/48766"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/121176"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In the oil and gas industry, H2S is a prevalent compound that arises from various geological processes (i.e., thermal and microbial sulfate reduction) and is also generated during some upgrading operations (i.e., hydrotreating). As such, immense efforts are taken not to release H2S into the environment during the exploitation of natural resources. In this context, the modified Claus process is the most widely used technology in sulfur recovery, whereby, across multiple thermal and catalytic stages, H2S gas is converted to elemental sulfur. While this is a mature technology, the waste heat boiler after the thermal reactor in the modified Claus process has a finite life. This is due to a corrosion phenomenon referred to as high-temperature sulfidic attack on the metal tubes providing thermal transfer from process gas to water/stream. However, there is a scarcity of kinetic models which can be used to predict corrosion rates under the aforementioned conditions, and the existing models are known to be unreliable. This research focuses on optimizing the method that is used to obtain steady-state corrosion rates. A custom-built furnace apparatus was used for these studies, and carbon steel coupons (ASTM A36) were used as the test material in the initial stages of this research. However, the use of coupons was discontinued and replaced by smaller metal spheres to increase accessible surface area. H2S concentrations ranging from 10 – 20 mol% were investigated, and some initial experiments probing the effect of H2O were also performed. Weight loss measurements using carbon steel spheres yielded a corrosion rate of 6.0 ± 0.3 mpy, while weight gain measurements (assuming FeS1.5) resulted in 5.1 ± 0.1 mpy. However, calculating the corrosion rate assuming FeS1.3 produced 5.9 ± 0.2 mpy, which is consistent with the weight loss method. In addition, preliminary thermogravimetric analyzer (TGA) investigations were conducted utilizing carbon steel spheres with a 20 mol% H2S feed gas stream. Combined with a comparison of the techniques, the TGA method shows promise for future experiments. Finally, the compositions of the resultant corrosion scales were studied using grazing incidence X-ray diffraction (GIXRD)."]},{"key":"dc:title","label":"Title","values":["High-temperature Sulfidic Attack on Carbon Steel and Select Alloys"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marriott, Robert A."],"dc:contributor.committeemember":["Birss, Viola Ingrid","Trudel, Simon","Shimizu, George Kisa Hayashi","Salahub, Dennis R."],"dc:creator":["Gunarathna, Madushan Dhammika"],"dc:date":["2025-06"],"dc:date.accessioned":["2025-04-29T21:57:18Z"],"dc:date.available":["2025-04-29T21:57:18Z"],"dc:date.issued":["2025-04-28"],"dc:description.abstract":["In the oil and gas industry, H2S is a prevalent compound that arises from various geological processes (i.e., thermal and microbial sulfate reduction) and is also generated during some upgrading operations (i.e., hydrotreating). As such, immense efforts are taken not to release H2S into the environment during the exploitation of natural resources. In this context, the modified Claus process is the most widely used technology in sulfur recovery, whereby, across multiple thermal and catalytic stages, H2S gas is converted to elemental sulfur. While this is a mature technology, the waste heat boiler after the thermal reactor in the modified Claus process has a finite life. This is due to a corrosion phenomenon referred to as high-temperature sulfidic attack on the metal tubes providing thermal transfer from process gas to water/stream. However, there is a scarcity of kinetic models which can be used to predict corrosion rates under the aforementioned conditions, and the existing models are known to be unreliable. This research focuses on optimizing the method that is used to obtain steady-state corrosion rates. A custom-built furnace apparatus was used for these studies, and carbon steel coupons (ASTM A36) were used as the test material in the initial stages of this research. However, the use of coupons was discontinued and replaced by smaller metal spheres to increase accessible surface area. H2S concentrations ranging from 10 – 20 mol% were investigated, and some initial experiments probing the effect of H2O were also performed. Weight loss measurements using carbon steel spheres yielded a corrosion rate of 6.0 ± 0.3 mpy, while weight gain measurements (assuming FeS1.5) resulted in 5.1 ± 0.1 mpy. However, calculating the corrosion rate assuming FeS1.3 produced 5.9 ± 0.2 mpy, which is consistent with the weight loss method. In addition, preliminary thermogravimetric analyzer (TGA) investigations were conducted utilizing carbon steel spheres with a 20 mol% H2S feed gas stream. Combined with a comparison of the techniques, the TGA method shows promise for future experiments. Finally, the compositions of the resultant corrosion scales were studied using grazing incidence X-ray diffraction (GIXRD)."],"dc:identifier.citation":["Gunarathna, M. D. (2025). High-temperature sulfidic attack on carbon steel and select alloys (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/48766"],"dc:identifier.uri":["https://hdl.handle.net/1880/121176"],"dc:language.iso":["en"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject.classification":["Chemistry--Physical"],"dc:title":["High-temperature Sulfidic Attack on Carbon Steel and Select Alloys"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"],"thesis:release_request":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]},"updated_at":"2026-11-19T07:37:07Z"}