{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/121818"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/121818","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"In Vivo and Ex Vivo Hysteresis of Sheep Medial Gastrocnemius and Plantaris Tendons","abstract":"The primary purpose of this thesis was to investigate the differences in tendon hystereses measured in vivo during sheep locomotion and ex vivo using materials testing machine. Sheep walked on a treadmill at various speeds and inclinations, and their respective tendons were tested ex vivo under the same in vivo loading conditions using an Instron machine. We directly accessed medial gastrocnemius (MG) in vivo muscle forces and tendon lengths using a buckle-type force transducer and a saline-filled silastic tube length sensor, respectively. The Instron recorded the ex vivo tendon force and length simultaneously. Across all conditions, our results suggest that in vivo tendon hysteresis was greater than those measured ex vivo. This difference is largely explained by the differences in testing environments (in vivo vs. ex vivo). The second study of this thesis aimed to investigate the differences in the ex vivo tendon hysteresis values measured using different force-time waveform generators. Experiments were conducted using an Instron machine, which measured the force and elongation of the MG and plantaris (PL) tendons. The in vivo tendon forces obtained during walking at varying speeds and slopes were programmed into the Instron to replicate the previously measured forces during free sheep locomotion. Sinusoidal and triangular force profiles matching the in vivo peak forces and frequencies were also programmed into the Instron. The triangular waveform consistently exhibited lower hysteresis values than the in vivo and sinusoidal waveform generators. MG tendon hystereses were consistently lower than PL tendon hystereses, when tested with cyclic loading frequencies and magnitudes that are observed during free locomotion. Therefore, we speculate that tendon hysteresis values depend on the imposed loading waveform condition. In summary, these studies provide insights into tendon hysteresis values measured in vivo and ex vivo by providing accurate and direct measurements of tendon lengths and corresponding muscle forces for a variety of movement conditions during both experiments with the same tendon and demonstrating that the force-time waveforms affect ex vivo tendon hysteresis values in a systematic manner.","abstract_html":"The primary purpose of this thesis was to investigate the differences in tendon hystereses measured in vivo during sheep locomotion and ex vivo using materials testing machine. Sheep walked on a treadmill at various speeds and inclinations, and their respective tendons were tested ex vivo under the same in vivo loading conditions using an Instron machine. We directly accessed medial gastrocnemius (MG) in vivo muscle forces and tendon lengths using a buckle-type force transducer and a saline-filled silastic tube length sensor, respectively. The Instron recorded the ex vivo tendon force and length simultaneously. Across all conditions, our results suggest that in vivo tendon hysteresis was greater than those measured ex vivo. This difference is largely explained by the differences in testing environments (in vivo vs. ex vivo). The second study of this thesis aimed to investigate the differences in the ex vivo tendon hysteresis values measured using different force-time waveform generators. Experiments were conducted using an Instron machine, which measured the force and elongation of the MG and plantaris (PL) tendons. The in vivo tendon forces obtained during walking at varying speeds and slopes were programmed into the Instron to replicate the previously measured forces during free sheep locomotion. Sinusoidal and triangular force profiles matching the in vivo peak forces and frequencies were also programmed into the Instron. The triangular waveform consistently exhibited lower hysteresis values than the in vivo and sinusoidal waveform generators. MG tendon hystereses were consistently lower than PL tendon hystereses, when tested with cyclic loading frequencies and magnitudes that are observed during free locomotion. Therefore, we speculate that tendon hysteresis values depend on the imposed loading waveform condition. In summary, these studies provide insights into tendon hysteresis values measured in vivo and ex vivo by providing accurate and direct measurements of tendon lengths and corresponding muscle forces for a variety of movement conditions during both experiments with the same tendon and demonstrating that the force-time waveforms affect ex vivo tendon hysteresis values in a systematic manner.","abstract_has_math":false,"creators":["Dos Santos, Esthevan Machado"],"institution":"University of Calgary","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Kinesiology","degree_department":null,"school":null,"contributors":[],"advisors":["Herzog, Walter","Fletcher, Jared R."],"committee_chairs":[],"committee_members":["Jordan, Matthew James","Scott, W. Michael","Lucas, Kelsey Noelle"],"year":2025,"date_issued":"2025-05-23","date_published":"2025-05-23","updated_at":"2026-11-19T07:26:32Z","subjects":["Tendon hysteresis","Sheep","In vivo experiments","Ex vivo experiments","Medial gastrocnemius","Plantaris","Locomotion","Waveforms","Mechanical property"],"languages":["en"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/121818"],"render_values":[{"text":"https://hdl.handle.net/1880/121818","href":"https://hdl.handle.net/1880/121818","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Dos Santos, E. M. (2025). In vivo and ex vivo hysteresis of sheep medial gastrocnemius and plantaris tendons (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Dos Santos, E. M. (2025). In vivo and ex vivo hysteresis of sheep medial gastrocnemius and plantaris tendons (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/49407","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/49407","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F121818","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F121818","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Herzog, Walter","Fletcher, Jared R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Jordan, Matthew James","Scott, W. Michael","Lucas, Kelsey Noelle"]},{"key":"dc:creator","label":"Author","values":["Dos Santos, Esthevan Machado"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-26T19:05:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-26T19:05:17Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-05-23"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Kinesiology"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:release_request","label":"Thesis Release Request","values":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Tendon hysteresis","Sheep","In vivo experiments","Ex vivo experiments","Medial gastrocnemius","Plantaris","Locomotion","Waveforms","Mechanical property"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Education--Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Dos Santos, E. M. (2025). In vivo and ex vivo hysteresis of sheep medial gastrocnemius and plantaris tendons (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/49407"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/121818"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The primary purpose of this thesis was to investigate the differences in tendon hystereses measured in vivo during sheep locomotion and ex vivo using materials testing machine. Sheep walked on a treadmill at various speeds and inclinations, and their respective tendons were tested ex vivo under the same in vivo loading conditions using an Instron machine. We directly accessed medial gastrocnemius (MG) in vivo muscle forces and tendon lengths using a buckle-type force transducer and a saline-filled silastic tube length sensor, respectively. The Instron recorded the ex vivo tendon force and length simultaneously. Across all conditions, our results suggest that in vivo tendon hysteresis was greater than those measured ex vivo. This difference is largely explained by the differences in testing environments (in vivo vs. ex vivo). The second study of this thesis aimed to investigate the differences in the ex vivo tendon hysteresis values measured using different force-time waveform generators. Experiments were conducted using an Instron machine, which measured the force and elongation of the MG and plantaris (PL) tendons. The in vivo tendon forces obtained during walking at varying speeds and slopes were programmed into the Instron to replicate the previously measured forces during free sheep locomotion. Sinusoidal and triangular force profiles matching the in vivo peak forces and frequencies were also programmed into the Instron. The triangular waveform consistently exhibited lower hysteresis values than the in vivo and sinusoidal waveform generators. MG tendon hystereses were consistently lower than PL tendon hystereses, when tested with cyclic loading frequencies and magnitudes that are observed during free locomotion. Therefore, we speculate that tendon hysteresis values depend on the imposed loading waveform condition. In summary, these studies provide insights into tendon hysteresis values measured in vivo and ex vivo by providing accurate and direct measurements of tendon lengths and corresponding muscle forces for a variety of movement conditions during both experiments with the same tendon and demonstrating that the force-time waveforms affect ex vivo tendon hysteresis values in a systematic manner."]},{"key":"dc:title","label":"Title","values":["In Vivo and Ex Vivo Hysteresis of Sheep Medial Gastrocnemius and Plantaris Tendons"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Herzog, Walter","Fletcher, Jared R."],"dc:contributor.committeemember":["Jordan, Matthew James","Scott, W. Michael","Lucas, Kelsey Noelle"],"dc:creator":["Dos Santos, Esthevan Machado"],"dc:date":["2025-11"],"dc:date.accessioned":["2025-05-26T19:05:17Z"],"dc:date.available":["2025-05-26T19:05:17Z"],"dc:date.issued":["2025-05-23"],"dc:description.abstract":["The primary purpose of this thesis was to investigate the differences in tendon hystereses measured in vivo during sheep locomotion and ex vivo using materials testing machine. Sheep walked on a treadmill at various speeds and inclinations, and their respective tendons were tested ex vivo under the same in vivo loading conditions using an Instron machine. We directly accessed medial gastrocnemius (MG) in vivo muscle forces and tendon lengths using a buckle-type force transducer and a saline-filled silastic tube length sensor, respectively. The Instron recorded the ex vivo tendon force and length simultaneously. Across all conditions, our results suggest that in vivo tendon hysteresis was greater than those measured ex vivo. This difference is largely explained by the differences in testing environments (in vivo vs. ex vivo). The second study of this thesis aimed to investigate the differences in the ex vivo tendon hysteresis values measured using different force-time waveform generators. Experiments were conducted using an Instron machine, which measured the force and elongation of the MG and plantaris (PL) tendons. The in vivo tendon forces obtained during walking at varying speeds and slopes were programmed into the Instron to replicate the previously measured forces during free sheep locomotion. Sinusoidal and triangular force profiles matching the in vivo peak forces and frequencies were also programmed into the Instron. The triangular waveform consistently exhibited lower hysteresis values than the in vivo and sinusoidal waveform generators. MG tendon hystereses were consistently lower than PL tendon hystereses, when tested with cyclic loading frequencies and magnitudes that are observed during free locomotion. Therefore, we speculate that tendon hysteresis values depend on the imposed loading waveform condition. In summary, these studies provide insights into tendon hysteresis values measured in vivo and ex vivo by providing accurate and direct measurements of tendon lengths and corresponding muscle forces for a variety of movement conditions during both experiments with the same tendon and demonstrating that the force-time waveforms affect ex vivo tendon hysteresis values in a systematic manner."],"dc:identifier.citation":["Dos Santos, E. M. (2025). In vivo and ex vivo hysteresis of sheep medial gastrocnemius and plantaris tendons (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/49407"],"dc:identifier.uri":["https://hdl.handle.net/1880/121818"],"dc:language.iso":["en"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Tendon hysteresis","Sheep","In vivo experiments","Ex vivo experiments","Medial gastrocnemius","Plantaris","Locomotion","Waveforms","Mechanical property"],"dc:subject.classification":["Education--Sciences"],"dc:title":["In Vivo and Ex Vivo Hysteresis of Sheep Medial Gastrocnemius and Plantaris Tendons"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Kinesiology"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"],"thesis:release_request":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]},"updated_at":"2026-11-19T07:26:32Z"}