{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/121855"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/121855","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"The Impact of the Philips Positive Airway Pressure (PAP) Medical Device Recall on PAP Adherence: A Retrospective Observational Study of an Alberta Clinical Cohort.","abstract":"Obstructive sleep apnea (OSA) is a common sleep related breathing disorder that can have numerous detrimental impacts to the individual and society. Positive airway pressure (PAP) therapy is an effective treatment method for OSA that can help reduce symptoms of daytime sleepiness, decrease risk of motor vehicle accidents, and improve quality of life. In June 2021, Philips Respironics, a major PAP device manufacturer, issued a recall of their devices due to sound abatement foam degrading and entering users’ airways. This retrospective single-centre observational cohort study aimed to determine if there were changes in PAP adherence from before to after the Philips recall was announced, and if there were differences in adherence among those with recalled versus non-recalled devices. A secondary aim was to determine if there was an association between social vulnerability and change in PAP adherence after the recall, using a validated measure (Canadian Index of Multiple Deprivation – CIMD). We used routinely collected clinical data from a tertiary care sleep clinic, including objective PAP adherence data from device downloads, and postal code-derived social vulnerability measures from Census data. The cohort consisted of 2,049 unique patients at the Foothills Medical Centre Sleep Centre in Calgary, Alberta, with a total of 4,573 PAP device adherence downloads. Overall, there were no significant effects on PAP adherence due to the recall after adjustment for potential confounders including by device manufacturer. There were modest but statistically significant associations found between two CIMD domains and increased PAP adherence post-recall suggesting a potential relationship between social vulnerability and PAP adherence in the context of a device recall. Overall, we did not find strong evidence to suggest that the Philips Respironics PAP recall significantly impacted PAP use at this tertiary care sleep centre.","abstract_html":"Obstructive sleep apnea (OSA) is a common sleep related breathing disorder that can have numerous detrimental impacts to the individual and society. Positive airway pressure (PAP) therapy is an effective treatment method for OSA that can help reduce symptoms of daytime sleepiness, decrease risk of motor vehicle accidents, and improve quality of life. In June 2021, Philips Respironics, a major PAP device manufacturer, issued a recall of their devices due to sound abatement foam degrading and entering users’ airways. This retrospective single-centre observational cohort study aimed to determine if there were changes in PAP adherence from before to after the Philips recall was announced, and if there were differences in adherence among those with recalled versus non-recalled devices. A secondary aim was to determine if there was an association between social vulnerability and change in PAP adherence after the recall, using a validated measure (Canadian Index of Multiple Deprivation – CIMD). We used routinely collected clinical data from a tertiary care sleep clinic, including objective PAP adherence data from device downloads, and postal code-derived social vulnerability measures from Census data. The cohort consisted of 2,049 unique patients at the Foothills Medical Centre Sleep Centre in Calgary, Alberta, with a total of 4,573 PAP device adherence downloads. Overall, there were no significant effects on PAP adherence due to the recall after adjustment for potential confounders including by device manufacturer. There were modest but statistically significant associations found between two CIMD domains and increased PAP adherence post-recall suggesting a potential relationship between social vulnerability and PAP adherence in the context of a device recall. Overall, we did not find strong evidence to suggest that the Philips Respironics PAP recall significantly impacted PAP use at this tertiary care sleep centre.","abstract_has_math":false,"creators":["Grant, Emma"],"institution":"Cumming School of Medicine","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Medicine – Medical Sciences","degree_department":null,"school":null,"contributors":[],"advisors":["Pendharkar, Sachin"],"committee_chairs":[],"committee_members":["Kendzerska, Tetyana","Donald, Maoliosa","McBrien, Kerry"],"year":2025,"date_issued":"2025-06-03","date_published":"2025-06-03","updated_at":"2026-11-19T07:36:41Z","subjects":["Obstructive Sleep Apnea","Medical Device Recall"],"languages":["en"],"rights":["Unless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/49445"],"render_values":[{"text":"https://dx.doi.org/10.11575/PRISM/49445","href":"https://dx.doi.org/10.11575/PRISM/49445","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Grant, E. (2025). The impact of the Philips Positive Airway Pressure (PAP) medical device recall on PAP adherence: a retrospective observational study of an Alberta clinical cohort (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Grant, E. (2025). The impact of the Philips Positive Airway Pressure (PAP) medical device recall on PAP adherence: a retrospective observational study of an Alberta clinical cohort (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1880/121855","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1880/121855","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F121855","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Pendharkar, Sachin"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kendzerska, Tetyana","Donald, Maoliosa","McBrien, Kerry"]},{"key":"dc:creator","label":"Author","values":["Grant, Emma"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-06"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-06-03T19:28:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-06-03T19:28:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-06-03"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Cumming School of Medicine"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Medicine – Medical Sciences"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:release_request","label":"Thesis Release Request","values":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Obstructive Sleep Apnea","Medical Device Recall"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Epidemiology","Public Health"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Unless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Grant, E. (2025). The impact of the Philips Positive Airway Pressure (PAP) medical device recall on PAP adherence: a retrospective observational study of an Alberta clinical cohort (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/49445"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/121855"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Obstructive sleep apnea (OSA) is a common sleep related breathing disorder that can have numerous detrimental impacts to the individual and society. Positive airway pressure (PAP) therapy is an effective treatment method for OSA that can help reduce symptoms of daytime sleepiness, decrease risk of motor vehicle accidents, and improve quality of life. In June 2021, Philips Respironics, a major PAP device manufacturer, issued a recall of their devices due to sound abatement foam degrading and entering users’ airways. This retrospective single-centre observational cohort study aimed to determine if there were changes in PAP adherence from before to after the Philips recall was announced, and if there were differences in adherence among those with recalled versus non-recalled devices. A secondary aim was to determine if there was an association between social vulnerability and change in PAP adherence after the recall, using a validated measure (Canadian Index of Multiple Deprivation – CIMD). We used routinely collected clinical data from a tertiary care sleep clinic, including objective PAP adherence data from device downloads, and postal code-derived social vulnerability measures from Census data. The cohort consisted of 2,049 unique patients at the Foothills Medical Centre Sleep Centre in Calgary, Alberta, with a total of 4,573 PAP device adherence downloads. Overall, there were no significant effects on PAP adherence due to the recall after adjustment for potential confounders including by device manufacturer. There were modest but statistically significant associations found between two CIMD domains and increased PAP adherence post-recall suggesting a potential relationship between social vulnerability and PAP adherence in the context of a device recall. Overall, we did not find strong evidence to suggest that the Philips Respironics PAP recall significantly impacted PAP use at this tertiary care sleep centre."]},{"key":"dc:title","label":"Title","values":["The Impact of the Philips Positive Airway Pressure (PAP) Medical Device Recall on PAP Adherence: A Retrospective Observational Study of an Alberta Clinical Cohort."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Pendharkar, Sachin"],"dc:contributor.committeemember":["Kendzerska, Tetyana","Donald, Maoliosa","McBrien, Kerry"],"dc:creator":["Grant, Emma"],"dc:date":["2025-06"],"dc:date.accessioned":["2025-06-03T19:28:50Z"],"dc:date.available":["2025-06-03T19:28:50Z"],"dc:date.issued":["2025-06-03"],"dc:description.abstract":["Obstructive sleep apnea (OSA) is a common sleep related breathing disorder that can have numerous detrimental impacts to the individual and society. Positive airway pressure (PAP) therapy is an effective treatment method for OSA that can help reduce symptoms of daytime sleepiness, decrease risk of motor vehicle accidents, and improve quality of life. In June 2021, Philips Respironics, a major PAP device manufacturer, issued a recall of their devices due to sound abatement foam degrading and entering users’ airways. This retrospective single-centre observational cohort study aimed to determine if there were changes in PAP adherence from before to after the Philips recall was announced, and if there were differences in adherence among those with recalled versus non-recalled devices. A secondary aim was to determine if there was an association between social vulnerability and change in PAP adherence after the recall, using a validated measure (Canadian Index of Multiple Deprivation – CIMD). We used routinely collected clinical data from a tertiary care sleep clinic, including objective PAP adherence data from device downloads, and postal code-derived social vulnerability measures from Census data. The cohort consisted of 2,049 unique patients at the Foothills Medical Centre Sleep Centre in Calgary, Alberta, with a total of 4,573 PAP device adherence downloads. Overall, there were no significant effects on PAP adherence due to the recall after adjustment for potential confounders including by device manufacturer. There were modest but statistically significant associations found between two CIMD domains and increased PAP adherence post-recall suggesting a potential relationship between social vulnerability and PAP adherence in the context of a device recall. Overall, we did not find strong evidence to suggest that the Philips Respironics PAP recall significantly impacted PAP use at this tertiary care sleep centre."],"dc:identifier.citation":["Grant, E. (2025). The impact of the Philips Positive Airway Pressure (PAP) medical device recall on PAP adherence: a retrospective observational study of an Alberta clinical cohort (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/49445"],"dc:identifier.uri":["https://hdl.handle.net/1880/121855"],"dc:language.iso":["en"],"dc:publisher.faculty":["Cumming School of Medicine"],"dc:rights":["Unless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Obstructive Sleep Apnea","Medical Device Recall"],"dc:subject.classification":["Epidemiology","Public Health"],"dc:title":["The Impact of the Philips Positive Airway Pressure (PAP) Medical Device Recall on PAP Adherence: A Retrospective Observational Study of an Alberta Clinical Cohort."],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Medicine – Medical Sciences"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"],"thesis:release_request":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]},"updated_at":"2026-11-19T07:36:41Z"}