{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/122467"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/122467","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Super-Resolution of Cone Beam Computed Tomography: Applications in Bone Analysis for Rheumatoid Arthritis","abstract":"Rheumatoid arthritis (RA) is a chronic inflammatory disease characterized by bone erosions, which serve as critical indicators of disease progression and structural damage. High-resolution peripheral quantitative computed tomography (HR-pQCT) is the reference standard for imaging these erosions but is constrained by limited anatomical coverage and long acquisition times. In contrast, cone beam computed tomography (CBCT) offers faster imaging with broader coverage but insufficient resolution for detailed erosion assessment. To address this, a curriculum learning-based CycleGAN framework was developed to super-resolve CBCT images to HR-pQCT quality, enabling more accurate extraction of structural information. To support automated erosion detection and quantification, an atlas of healthy hand bones was constructed. This atlas served as an anatomical prior in a deep learning pipeline, AG-UNet (atlas-guided nnUNet). By providing spatial context from healthy anatomy, the atlas acted as an anatomical prior to improve segmentation accuracy. The super-resolution framework was trained in a staged manner, beginning with paired synthetic data and progressing to unpaired real CBCT and HR-pQCT scans. This approach yielded improved image quality, significantly enhanced similarity metrics, and reduced trabecular bone errors across stages (p < 0.001). A blinded rheumatologist classified 40% of super-resolved images as HR-pQCT, confirming perceptual quality and diagnostic relevance as all RA erosions remained manually identifiable in the enhanced images. AG-UNet was trained on manually annotated erosions in the 2nd and 3rd metacarpophalangeal joints. On HR-pQCT, the model achieved strong agreement with manual volumes (Pearson r = 0.946, MAE = 1.90 mm³) and 92.3% detection sensitivity. When applied to super-resolved CBCT, sensitivity was 71.4%, improving for larger erosions. Volume estimates from super-resolved CBCT were well correlated with HR-pQCT (r = 0.890), and longitudinal tracking of 21 erosions over one year showed moderate agreement in change scores (r = 0.613) with no significant bias. These findings demonstrate that super-resolution enhances the amount of meaningful structural information that can be extracted from lower-resolution CBCT scans, beyond what is possible at native resolution and expanding the utility of musculoskeletal CBCT.","abstract_html":"Rheumatoid arthritis (RA) is a chronic inflammatory disease characterized by bone erosions, which serve as critical indicators of disease progression and structural damage. High-resolution peripheral quantitative computed tomography (HR-pQCT) is the reference standard for imaging these erosions but is constrained by limited anatomical coverage and long acquisition times. In contrast, cone beam computed tomography (CBCT) offers faster imaging with broader coverage but insufficient resolution for detailed erosion assessment. To address this, a curriculum learning-based CycleGAN framework was developed to super-resolve CBCT images to HR-pQCT quality, enabling more accurate extraction of structural information. To support automated erosion detection and quantification, an atlas of healthy hand bones was constructed. This atlas served as an anatomical prior in a deep learning pipeline, AG-UNet (atlas-guided nnUNet). By providing spatial context from healthy anatomy, the atlas acted as an anatomical prior to improve segmentation accuracy. The super-resolution framework was trained in a staged manner, beginning with paired synthetic data and progressing to unpaired real CBCT and HR-pQCT scans. This approach yielded improved image quality, significantly enhanced similarity metrics, and reduced trabecular bone errors across stages (p &lt; 0.001). A blinded rheumatologist classified 40% of super-resolved images as HR-pQCT, confirming perceptual quality and diagnostic relevance as all RA erosions remained manually identifiable in the enhanced images. AG-UNet was trained on manually annotated erosions in the 2nd and 3rd metacarpophalangeal joints. On HR-pQCT, the model achieved strong agreement with manual volumes (Pearson r = 0.946, MAE = 1.90 mm³) and 92.3% detection sensitivity. When applied to super-resolved CBCT, sensitivity was 71.4%, improving for larger erosions. Volume estimates from super-resolved CBCT were well correlated with HR-pQCT (r = 0.890), and longitudinal tracking of 21 erosions over one year showed moderate agreement in change scores (r = 0.613) with no significant bias. These findings demonstrate that super-resolution enhances the amount of meaningful structural information that can be extracted from lower-resolution CBCT scans, beyond what is possible at native resolution and expanding the utility of musculoskeletal CBCT.","abstract_has_math":false,"creators":["Al-Khoury, Yousif Costantien"],"institution":"Schulich School of Engineering","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Engineering – Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":["Manske, Sarah L.","MacDonald, M. Ethan"],"committee_chairs":[],"committee_members":["Barber, Claire E. H.","Gobbi, David G.","Wilms, Matthias"],"year":2025,"date_issued":"2025-08-12","date_published":"2025-08-12","updated_at":"2026-11-19T07:26:39Z","subjects":["Medical Imaging","Computed Tomography","Generative AI","Artificial Intelligence","Computer Vision","Image Processing","Rheumatoid Arthritis","Bone","Musculoskeletal"],"languages":["en"],"rights":["Unless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/50060"],"render_values":[{"text":"https://dx.doi.org/10.11575/PRISM/50060","href":"https://dx.doi.org/10.11575/PRISM/50060","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Al-Khoury, Y. (2025). Super-resolution of cone beam computed tomography: applications in bone analysis for rheumatoid arthritis (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Al-Khoury, Y. (2025). Super-resolution of cone beam computed tomography: applications in bone analysis for rheumatoid arthritis (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1880/122467","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1880/122467","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F122467","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Manske, Sarah L.","MacDonald, M. Ethan"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Barber, Claire E. H.","Gobbi, David G.","Wilms, Matthias"]},{"key":"dc:creator","label":"Author","values":["Al-Khoury, Yousif Costantien"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-08-13T19:41:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-08-13T19:41:45Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-08-12"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Schulich School of Engineering"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering – Biomedical"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:release_request","label":"Thesis Release Request","values":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Medical Imaging","Computed Tomography","Generative AI","Artificial Intelligence","Computer Vision","Image Processing","Rheumatoid Arthritis","Bone","Musculoskeletal"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Engineering--Biomedical","Artificial Intelligence"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Unless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Al-Khoury, Y. (2025). Super-resolution of cone beam computed tomography: applications in bone analysis for rheumatoid arthritis (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/50060"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/122467"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Rheumatoid arthritis (RA) is a chronic inflammatory disease characterized by bone erosions, which serve as critical indicators of disease progression and structural damage. High-resolution peripheral quantitative computed tomography (HR-pQCT) is the reference standard for imaging these erosions but is constrained by limited anatomical coverage and long acquisition times. In contrast, cone beam computed tomography (CBCT) offers faster imaging with broader coverage but insufficient resolution for detailed erosion assessment. To address this, a curriculum learning-based CycleGAN framework was developed to super-resolve CBCT images to HR-pQCT quality, enabling more accurate extraction of structural information. To support automated erosion detection and quantification, an atlas of healthy hand bones was constructed. This atlas served as an anatomical prior in a deep learning pipeline, AG-UNet (atlas-guided nnUNet). By providing spatial context from healthy anatomy, the atlas acted as an anatomical prior to improve segmentation accuracy. The super-resolution framework was trained in a staged manner, beginning with paired synthetic data and progressing to unpaired real CBCT and HR-pQCT scans. This approach yielded improved image quality, significantly enhanced similarity metrics, and reduced trabecular bone errors across stages (p < 0.001). A blinded rheumatologist classified 40% of super-resolved images as HR-pQCT, confirming perceptual quality and diagnostic relevance as all RA erosions remained manually identifiable in the enhanced images. AG-UNet was trained on manually annotated erosions in the 2nd and 3rd metacarpophalangeal joints. On HR-pQCT, the model achieved strong agreement with manual volumes (Pearson r = 0.946, MAE = 1.90 mm³) and 92.3% detection sensitivity. When applied to super-resolved CBCT, sensitivity was 71.4%, improving for larger erosions. Volume estimates from super-resolved CBCT were well correlated with HR-pQCT (r = 0.890), and longitudinal tracking of 21 erosions over one year showed moderate agreement in change scores (r = 0.613) with no significant bias. These findings demonstrate that super-resolution enhances the amount of meaningful structural information that can be extracted from lower-resolution CBCT scans, beyond what is possible at native resolution and expanding the utility of musculoskeletal CBCT."]},{"key":"dc:title","label":"Title","values":["Super-Resolution of Cone Beam Computed Tomography: Applications in Bone Analysis for Rheumatoid Arthritis"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Manske, Sarah L.","MacDonald, M. Ethan"],"dc:contributor.committeemember":["Barber, Claire E. H.","Gobbi, David G.","Wilms, Matthias"],"dc:creator":["Al-Khoury, Yousif Costantien"],"dc:date":["2025-11"],"dc:date.accessioned":["2025-08-13T19:41:45Z"],"dc:date.available":["2025-08-13T19:41:45Z"],"dc:date.issued":["2025-08-12"],"dc:description.abstract":["Rheumatoid arthritis (RA) is a chronic inflammatory disease characterized by bone erosions, which serve as critical indicators of disease progression and structural damage. High-resolution peripheral quantitative computed tomography (HR-pQCT) is the reference standard for imaging these erosions but is constrained by limited anatomical coverage and long acquisition times. In contrast, cone beam computed tomography (CBCT) offers faster imaging with broader coverage but insufficient resolution for detailed erosion assessment. To address this, a curriculum learning-based CycleGAN framework was developed to super-resolve CBCT images to HR-pQCT quality, enabling more accurate extraction of structural information. To support automated erosion detection and quantification, an atlas of healthy hand bones was constructed. This atlas served as an anatomical prior in a deep learning pipeline, AG-UNet (atlas-guided nnUNet). By providing spatial context from healthy anatomy, the atlas acted as an anatomical prior to improve segmentation accuracy. The super-resolution framework was trained in a staged manner, beginning with paired synthetic data and progressing to unpaired real CBCT and HR-pQCT scans. This approach yielded improved image quality, significantly enhanced similarity metrics, and reduced trabecular bone errors across stages (p < 0.001). A blinded rheumatologist classified 40% of super-resolved images as HR-pQCT, confirming perceptual quality and diagnostic relevance as all RA erosions remained manually identifiable in the enhanced images. AG-UNet was trained on manually annotated erosions in the 2nd and 3rd metacarpophalangeal joints. On HR-pQCT, the model achieved strong agreement with manual volumes (Pearson r = 0.946, MAE = 1.90 mm³) and 92.3% detection sensitivity. When applied to super-resolved CBCT, sensitivity was 71.4%, improving for larger erosions. Volume estimates from super-resolved CBCT were well correlated with HR-pQCT (r = 0.890), and longitudinal tracking of 21 erosions over one year showed moderate agreement in change scores (r = 0.613) with no significant bias. These findings demonstrate that super-resolution enhances the amount of meaningful structural information that can be extracted from lower-resolution CBCT scans, beyond what is possible at native resolution and expanding the utility of musculoskeletal CBCT."],"dc:identifier.citation":["Al-Khoury, Y. (2025). Super-resolution of cone beam computed tomography: applications in bone analysis for rheumatoid arthritis (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/50060"],"dc:identifier.uri":["https://hdl.handle.net/1880/122467"],"dc:language.iso":["en"],"dc:publisher.faculty":["Schulich School of Engineering"],"dc:rights":["Unless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Medical Imaging","Computed Tomography","Generative AI","Artificial Intelligence","Computer Vision","Image Processing","Rheumatoid Arthritis","Bone","Musculoskeletal"],"dc:subject.classification":["Engineering--Biomedical","Artificial Intelligence"],"dc:title":["Super-Resolution of Cone Beam Computed Tomography: Applications in Bone Analysis for Rheumatoid Arthritis"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering – Biomedical"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"],"thesis:release_request":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]},"updated_at":"2026-11-19T07:26:39Z"}