{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/124396"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/124396","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Breast Imaging with Microwaves: Interpreting Images and Signals through Multimodal Registration and Signal Classification","abstract":"Early detection of breast cancer is critical to improving outcomes for patients. While x-ray mammography is the current gold standard, limitations include ionizing radiation and reduced sensitivity in dense breast tissue. Microwave breast imaging (MBI) offers a promising, complementary technology to mammography that measures the dielectric properties (permittivity) of the tissue to identify abnormalities. However, clinical validation of MBI remains challenging because the geometry and placement of the breast in the imaging system differs from mammography and few tools exist to relate these images to established clinical modalities. These limitations of MBI can be addressed by using laser scanning to understand the breast placement, supporting image interpretation and tissue classification. This research aims to improve the accuracy and clinical relevance of MBI by combining laser scanning of breast placement, multimodal image registration with mammography, and frequency domain signal analysis, demonstrating sub-centimeter consistency of breast placement and quantifiable correspondence between microwave permittivity and fibroglandular tissue. First, a laser scanning workflow was developed to measure 3D breast shape and volume and assess the consistency across multiple placements of the breast in the microwave scanner. This enables assessment of positional changes between scans and corresponding impact on the image. Second, contours describing the surface of the breast were derived from the laser scans and used to register microwave images with mammograms, enabling comparison between dielectric properties and fibroglandular tissue distribution. This has not been possible with other MBI systems. Finally, frequency domain microwave signals were analyzed using principal component analysis and clustering to identify signal features that correspond to the underlying tissue types. This analysis aims to provide interpretability to the signals used to create images and therefore improves confidence in identifying regions of interest such as fibroglandular tissue or tumours. Results demonstrated spatial correspondence between high permittivity regions and fibroglandular tissue. Expected signal characteristics reflecting tissue composition were related to the permittivity values in the microwave image. These findings establish a foundation for more accurate, consistent, and clinically interpretable microwave breast imaging, supporting its translation toward breast health and diagnostics applications.","abstract_html":"Early detection of breast cancer is critical to improving outcomes for patients. While x-ray mammography is the current gold standard, limitations include ionizing radiation and reduced sensitivity in dense breast tissue. Microwave breast imaging (MBI) offers a promising, complementary technology to mammography that measures the dielectric properties (permittivity) of the tissue to identify abnormalities. However, clinical validation of MBI remains challenging because the geometry and placement of the breast in the imaging system differs from mammography and few tools exist to relate these images to established clinical modalities. These limitations of MBI can be addressed by using laser scanning to understand the breast placement, supporting image interpretation and tissue classification. This research aims to improve the accuracy and clinical relevance of MBI by combining laser scanning of breast placement, multimodal image registration with mammography, and frequency domain signal analysis, demonstrating sub-centimeter consistency of breast placement and quantifiable correspondence between microwave permittivity and fibroglandular tissue. First, a laser scanning workflow was developed to measure 3D breast shape and volume and assess the consistency across multiple placements of the breast in the microwave scanner. This enables assessment of positional changes between scans and corresponding impact on the image. Second, contours describing the surface of the breast were derived from the laser scans and used to register microwave images with mammograms, enabling comparison between dielectric properties and fibroglandular tissue distribution. This has not been possible with other MBI systems. Finally, frequency domain microwave signals were analyzed using principal component analysis and clustering to identify signal features that correspond to the underlying tissue types. This analysis aims to provide interpretability to the signals used to create images and therefore improves confidence in identifying regions of interest such as fibroglandular tissue or tumours. Results demonstrated spatial correspondence between high permittivity regions and fibroglandular tissue. Expected signal characteristics reflecting tissue composition were related to the permittivity values in the microwave image. These findings establish a foundation for more accurate, consistent, and clinically interpretable microwave breast imaging, supporting its translation toward breast health and diagnostics applications.","abstract_has_math":false,"creators":["Butterworth, Carina"],"institution":"Graduate Studies","degree_name":"Doctor of Philosophy (PhD)","degree_level":null,"degree_discipline":"Engineering – Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":["Fear, Elise Carolyn"],"committee_chairs":[],"committee_members":["Lichti, Derek","Manske, Sarah Lynn","Plume, Rene","Popovich, Milica"],"year":2026,"date_issued":"2026-03-26","date_published":"2026-03-26","updated_at":"2026-11-19T07:28:33Z","subjects":["microwave breast imaging","laser scanning","image registration","signal analysis"],"languages":["en"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/124396"],"render_values":[{"text":"https://hdl.handle.net/1880/124396","href":"https://hdl.handle.net/1880/124396","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Butterworth, C. (2026). Breast imaging with microwaves: interpreting images and signals through multimodal registration and signal classification (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Butterworth, C. (2026). Breast imaging with microwaves: interpreting images and signals through multimodal registration and signal classification (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/51208","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/51208","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F124396","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Fear, Elise Carolyn"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Lichti, Derek","Manske, Sarah Lynn","Plume, Rene","Popovich, Milica"]},{"key":"dc:creator","label":"Author","values":["Butterworth, Carina"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-06"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-03-27T17:24:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-03-26"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["doctoral thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering – Biomedical"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:release_request","label":"Thesis Release Request","values":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["microwave breast imaging","laser scanning","image registration","signal analysis"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Engineering--Biomedical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Butterworth, C. (2026). Breast imaging with microwaves: interpreting images and signals through multimodal registration and signal classification (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/51208"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/124396"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Early detection of breast cancer is critical to improving outcomes for patients. While x-ray mammography is the current gold standard, limitations include ionizing radiation and reduced sensitivity in dense breast tissue. Microwave breast imaging (MBI) offers a promising, complementary technology to mammography that measures the dielectric properties (permittivity) of the tissue to identify abnormalities. However, clinical validation of MBI remains challenging because the geometry and placement of the breast in the imaging system differs from mammography and few tools exist to relate these images to established clinical modalities. These limitations of MBI can be addressed by using laser scanning to understand the breast placement, supporting image interpretation and tissue classification. This research aims to improve the accuracy and clinical relevance of MBI by combining laser scanning of breast placement, multimodal image registration with mammography, and frequency domain signal analysis, demonstrating sub-centimeter consistency of breast placement and quantifiable correspondence between microwave permittivity and fibroglandular tissue. First, a laser scanning workflow was developed to measure 3D breast shape and volume and assess the consistency across multiple placements of the breast in the microwave scanner. This enables assessment of positional changes between scans and corresponding impact on the image. Second, contours describing the surface of the breast were derived from the laser scans and used to register microwave images with mammograms, enabling comparison between dielectric properties and fibroglandular tissue distribution. This has not been possible with other MBI systems. Finally, frequency domain microwave signals were analyzed using principal component analysis and clustering to identify signal features that correspond to the underlying tissue types. This analysis aims to provide interpretability to the signals used to create images and therefore improves confidence in identifying regions of interest such as fibroglandular tissue or tumours. Results demonstrated spatial correspondence between high permittivity regions and fibroglandular tissue. Expected signal characteristics reflecting tissue composition were related to the permittivity values in the microwave image. These findings establish a foundation for more accurate, consistent, and clinically interpretable microwave breast imaging, supporting its translation toward breast health and diagnostics applications."]},{"key":"dc:title","label":"Title","values":["Breast Imaging with Microwaves: Interpreting Images and Signals through Multimodal Registration and Signal Classification"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Fear, Elise Carolyn"],"dc:contributor.committeemember":["Lichti, Derek","Manske, Sarah Lynn","Plume, Rene","Popovich, Milica"],"dc:creator":["Butterworth, Carina"],"dc:date":["2026-06"],"dc:date.accessioned":["2026-03-27T17:24:18Z"],"dc:date.issued":["2026-03-26"],"dc:description.abstract":["Early detection of breast cancer is critical to improving outcomes for patients. While x-ray mammography is the current gold standard, limitations include ionizing radiation and reduced sensitivity in dense breast tissue. Microwave breast imaging (MBI) offers a promising, complementary technology to mammography that measures the dielectric properties (permittivity) of the tissue to identify abnormalities. However, clinical validation of MBI remains challenging because the geometry and placement of the breast in the imaging system differs from mammography and few tools exist to relate these images to established clinical modalities. These limitations of MBI can be addressed by using laser scanning to understand the breast placement, supporting image interpretation and tissue classification. This research aims to improve the accuracy and clinical relevance of MBI by combining laser scanning of breast placement, multimodal image registration with mammography, and frequency domain signal analysis, demonstrating sub-centimeter consistency of breast placement and quantifiable correspondence between microwave permittivity and fibroglandular tissue. First, a laser scanning workflow was developed to measure 3D breast shape and volume and assess the consistency across multiple placements of the breast in the microwave scanner. This enables assessment of positional changes between scans and corresponding impact on the image. Second, contours describing the surface of the breast were derived from the laser scans and used to register microwave images with mammograms, enabling comparison between dielectric properties and fibroglandular tissue distribution. This has not been possible with other MBI systems. Finally, frequency domain microwave signals were analyzed using principal component analysis and clustering to identify signal features that correspond to the underlying tissue types. This analysis aims to provide interpretability to the signals used to create images and therefore improves confidence in identifying regions of interest such as fibroglandular tissue or tumours. Results demonstrated spatial correspondence between high permittivity regions and fibroglandular tissue. Expected signal characteristics reflecting tissue composition were related to the permittivity values in the microwave image. These findings establish a foundation for more accurate, consistent, and clinically interpretable microwave breast imaging, supporting its translation toward breast health and diagnostics applications."],"dc:identifier.citation":["Butterworth, C. (2026). Breast imaging with microwaves: interpreting images and signals through multimodal registration and signal classification (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/51208"],"dc:identifier.uri":["https://hdl.handle.net/1880/124396"],"dc:language.iso":["en"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["microwave breast imaging","laser scanning","image registration","signal analysis"],"dc:subject.classification":["Engineering--Biomedical"],"dc:title":["Breast Imaging with Microwaves: Interpreting Images and Signals through Multimodal Registration and Signal Classification"],"dc:type":["doctoral thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering – Biomedical"],"thesis:degree_name":["Doctor of Philosophy (PhD)"],"thesis:institution_name":["University of Calgary"],"thesis:release_request":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]},"updated_at":"2026-11-19T07:28:33Z"}