{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/125824"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/125824","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Influence of Lung Tissue Heterogeneity on Dose Calculation in Stereotactic Body Radiation Therapy","abstract":"Stereotactic body radiation therapy (SBRT) is the standard of care to treat inoperable, early-stage non-small cell lung cancer. It delivers high doses of radiation to the target over a few fractions. This target is an expansion of the tissue-equivalent tumour into low-density tissue. Historically, lung SBRT treatments have been planned with the Analytical Anisotropic Algorithm. Recently, a newer and more accurate dose calculation algorithm, AcurosXB, has been introduced. This thesis characterizes the relationship between AcurosXB dose calculations and target density in the context of lung SBRT, with particular attention to cases where the added margin in an expanded target volume extends into very low-density lung tissue. Firstly, the superior accuracy of AcurosXB is established through dose calculation comparisons with Monte Carlo. Secondly, retrospective patient studies quantify the relationship between AcurosXB dose calculations and target density. Understanding this relationship enables future work to improve the dosimetry associated with lung SBRT.","abstract_html":"Stereotactic body radiation therapy (SBRT) is the standard of care to treat inoperable, early-stage non-small cell lung cancer. It delivers high doses of radiation to the target over a few fractions. This target is an expansion of the tissue-equivalent tumour into low-density tissue. Historically, lung SBRT treatments have been planned with the Analytical Anisotropic Algorithm. Recently, a newer and more accurate dose calculation algorithm, AcurosXB, has been introduced. This thesis characterizes the relationship between AcurosXB dose calculations and target density in the context of lung SBRT, with particular attention to cases where the added margin in an expanded target volume extends into very low-density lung tissue. Firstly, the superior accuracy of AcurosXB is established through dose calculation comparisons with Monte Carlo. Secondly, retrospective patient studies quantify the relationship between AcurosXB dose calculations and target density. Understanding this relationship enables future work to improve the dosimetry associated with lung SBRT.","abstract_has_math":false,"creators":["Moring, Mackenzie"],"institution":"Science","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Physics & Astronomy","degree_department":null,"school":null,"contributors":[],"advisors":["Morris, Donald","Kirkby, Charles"],"committee_chairs":[],"committee_members":["Morrison, Hali","Lim, Gerald","Cully, Christopher","Sun, Lingyue"],"year":2026,"date_issued":"2026-09-01","date_published":"2026-09-01","updated_at":"2026-11-19T07:11:08Z","subjects":["Lung Stereotactic Body Radiation Therapy","Treatment Planning"],"languages":["en"],"rights":["Unless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/125824"],"render_values":[{"text":"https://hdl.handle.net/1880/125824","href":"https://hdl.handle.net/1880/125824","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Moring, M. (2026). Influence of lung tissue heterogeneity on dose calculation in stereotactic body radiation therapy (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://ucalgary.scholaris.ca."],"render_values":[{"text":"Moring, M. (2026). Influence of lung tissue heterogeneity on dose calculation in stereotactic body radiation therapy (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://ucalgary.scholaris.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/51916","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/51916","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F125824","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F125824","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Morris, Donald","Kirkby, Charles"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Morrison, Hali","Lim, Gerald","Cully, Christopher","Sun, Lingyue"]},{"key":"dc:creator","label":"Author","values":["Moring, Mackenzie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-04T17:23:43Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-09-01"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Science"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics & Astronomy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:release_request","label":"Thesis Release Request","values":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Lung Stereotactic Body Radiation Therapy","Treatment Planning"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Physics","Physics--Radiation","Oncology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Unless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Moring, M. (2026). Influence of lung tissue heterogeneity on dose calculation in stereotactic body radiation therapy (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://ucalgary.scholaris.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/51916"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/125824"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Stereotactic body radiation therapy (SBRT) is the standard of care to treat inoperable, early-stage non-small cell lung cancer. It delivers high doses of radiation to the target over a few fractions. This target is an expansion of the tissue-equivalent tumour into low-density tissue. Historically, lung SBRT treatments have been planned with the Analytical Anisotropic Algorithm. Recently, a newer and more accurate dose calculation algorithm, AcurosXB, has been introduced. This thesis characterizes the relationship between AcurosXB dose calculations and target density in the context of lung SBRT, with particular attention to cases where the added margin in an expanded target volume extends into very low-density lung tissue. Firstly, the superior accuracy of AcurosXB is established through dose calculation comparisons with Monte Carlo. Secondly, retrospective patient studies quantify the relationship between AcurosXB dose calculations and target density. Understanding this relationship enables future work to improve the dosimetry associated with lung SBRT."]},{"key":"dc:title","label":"Title","values":["Influence of Lung Tissue Heterogeneity on Dose Calculation in Stereotactic Body Radiation Therapy"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Morris, Donald","Kirkby, Charles"],"dc:contributor.committeemember":["Morrison, Hali","Lim, Gerald","Cully, Christopher","Sun, Lingyue"],"dc:creator":["Moring, Mackenzie"],"dc:date":["2026-11"],"dc:date.accessioned":["2026-09-04T17:23:43Z"],"dc:date.issued":["2026-09-01"],"dc:description.abstract":["Stereotactic body radiation therapy (SBRT) is the standard of care to treat inoperable, early-stage non-small cell lung cancer. It delivers high doses of radiation to the target over a few fractions. This target is an expansion of the tissue-equivalent tumour into low-density tissue. Historically, lung SBRT treatments have been planned with the Analytical Anisotropic Algorithm. Recently, a newer and more accurate dose calculation algorithm, AcurosXB, has been introduced. This thesis characterizes the relationship between AcurosXB dose calculations and target density in the context of lung SBRT, with particular attention to cases where the added margin in an expanded target volume extends into very low-density lung tissue. Firstly, the superior accuracy of AcurosXB is established through dose calculation comparisons with Monte Carlo. Secondly, retrospective patient studies quantify the relationship between AcurosXB dose calculations and target density. Understanding this relationship enables future work to improve the dosimetry associated with lung SBRT."],"dc:identifier.citation":["Moring, M. (2026). Influence of lung tissue heterogeneity on dose calculation in stereotactic body radiation therapy (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://ucalgary.scholaris.ca."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/51916"],"dc:identifier.uri":["https://hdl.handle.net/1880/125824"],"dc:language.iso":["en"],"dc:publisher.faculty":["Science"],"dc:rights":["Unless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Lung Stereotactic Body Radiation Therapy","Treatment Planning"],"dc:subject.classification":["Physics","Physics--Radiation","Oncology"],"dc:title":["Influence of Lung Tissue Heterogeneity on Dose Calculation in Stereotactic Body Radiation Therapy"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics & Astronomy"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"],"thesis:release_request":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]},"updated_at":"2026-11-19T07:11:08Z"}