{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/126105"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/126105","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Investigation on the Shear Strength and Capacity of Concrete Block Masonry","abstract":"Partially grouted concrete masonry shear walls are widely used because they provide a balance between structural performance and construction efficiency. However, the effects of material properties, grouting, and reinforcement on their shear resistance are not fully understood, and existing design methods often provide highly variable predictions. This study investigated the shear behaviour of concrete block masonry through literature review, material property testing, wall testing, and evaluation of predictive equations. A total of 169 masonry triplet specimens were tested to examine the effects of block condition and strength, grouting location and percentage, specimen configuration, age, and axial compression. The results supported the application of a Mohr-Coulomb criterion to hollow concrete block masonry. Unit compressive strength, grouting location, and specimen configuration had limited effects, while increasing grouting percentage and axial compression improved shear strength. The shear strength of partially grouted specimens could be estimated from the corresponding non-grouted and fully grouted specimens. Fifteen full-scale partially grouted masonry walls were tested under cyclic lateral loading to separate the effects of the grout in the bond beams from those of the horizontal reinforcement. Compared to grouting, the horizontal reinforcement produced only a limited increase in peak shear resistance. However, the presence of steel improved crack distribution, wall integrity, and post-peak behaviour. The wall tests also demonstrated considerable variability among similar specimens and between opposite loading directions. A database of 170 masonry shear walls was used to evaluate international standards and analytical models. Prediction accuracy generally improved when the horizontal reinforcement contribution was reduced or neglected for partially grouted walls. Mohr-Coulomb based methods and models that considered grouted and ungrouted masonry separately provided the most accurate predictions. A modified equation is proposed to estimate the shear resistance of both partially and fully grouted concrete masonry walls.","abstract_html":"Partially grouted concrete masonry shear walls are widely used because they provide a balance between structural performance and construction efficiency. However, the effects of material properties, grouting, and reinforcement on their shear resistance are not fully understood, and existing design methods often provide highly variable predictions. This study investigated the shear behaviour of concrete block masonry through literature review, material property testing, wall testing, and evaluation of predictive equations. A total of 169 masonry triplet specimens were tested to examine the effects of block condition and strength, grouting location and percentage, specimen configuration, age, and axial compression. The results supported the application of a Mohr-Coulomb criterion to hollow concrete block masonry. Unit compressive strength, grouting location, and specimen configuration had limited effects, while increasing grouting percentage and axial compression improved shear strength. The shear strength of partially grouted specimens could be estimated from the corresponding non-grouted and fully grouted specimens. Fifteen full-scale partially grouted masonry walls were tested under cyclic lateral loading to separate the effects of the grout in the bond beams from those of the horizontal reinforcement. Compared to grouting, the horizontal reinforcement produced only a limited increase in peak shear resistance. However, the presence of steel improved crack distribution, wall integrity, and post-peak behaviour. The wall tests also demonstrated considerable variability among similar specimens and between opposite loading directions. A database of 170 masonry shear walls was used to evaluate international standards and analytical models. Prediction accuracy generally improved when the horizontal reinforcement contribution was reduced or neglected for partially grouted walls. Mohr-Coulomb based methods and models that considered grouted and ungrouted masonry separately provided the most accurate predictions. A modified equation is proposed to estimate the shear resistance of both partially and fully grouted concrete masonry walls.","abstract_has_math":false,"creators":["Zhu, Jianyixian"],"institution":"Schulich School of Engineering","degree_name":"Doctor of Philosophy (PhD)","degree_level":null,"degree_discipline":"Engineering – Civil","degree_department":null,"school":null,"contributors":[],"advisors":["Shrive, Nigel Graham"],"committee_chairs":[],"committee_members":["El-Hacha, Raafat","Wong, Ron Chik-Kwong","Mehta, Sudarshan A.","Liu, Yi"],"year":2026,"date_issued":"2026-09-14","date_published":"2026-09-14","updated_at":"2026-11-19T07:11:15Z","subjects":[],"languages":["en"],"rights":["Unless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/126105"],"render_values":[{"text":"https://hdl.handle.net/1880/126105","href":"https://hdl.handle.net/1880/126105","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Zhu, J. (2026). Investigation on the shear strength and capacity of concrete block masonry (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Zhu, J. (2026). Investigation on the shear strength and capacity of concrete block masonry (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/52032","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/52032","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F126105","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F126105","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Shrive, Nigel Graham"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["El-Hacha, Raafat","Wong, Ron Chik-Kwong","Mehta, Sudarshan A.","Liu, Yi"]},{"key":"dc:creator","label":"Author","values":["Zhu, Jianyixian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-17T19:00:56Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-09-14"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Schulich School of Engineering"]},{"key":"dc:type","label":"Dc Type","values":["doctoral thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering – Civil"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:release_request","label":"Thesis Release Request","values":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Engineering--Civil"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Unless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Zhu, J. (2026). Investigation on the shear strength and capacity of concrete block masonry (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/52032"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/126105"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Partially grouted concrete masonry shear walls are widely used because they provide a balance between structural performance and construction efficiency. However, the effects of material properties, grouting, and reinforcement on their shear resistance are not fully understood, and existing design methods often provide highly variable predictions. This study investigated the shear behaviour of concrete block masonry through literature review, material property testing, wall testing, and evaluation of predictive equations. A total of 169 masonry triplet specimens were tested to examine the effects of block condition and strength, grouting location and percentage, specimen configuration, age, and axial compression. The results supported the application of a Mohr-Coulomb criterion to hollow concrete block masonry. Unit compressive strength, grouting location, and specimen configuration had limited effects, while increasing grouting percentage and axial compression improved shear strength. The shear strength of partially grouted specimens could be estimated from the corresponding non-grouted and fully grouted specimens. Fifteen full-scale partially grouted masonry walls were tested under cyclic lateral loading to separate the effects of the grout in the bond beams from those of the horizontal reinforcement. Compared to grouting, the horizontal reinforcement produced only a limited increase in peak shear resistance. However, the presence of steel improved crack distribution, wall integrity, and post-peak behaviour. The wall tests also demonstrated considerable variability among similar specimens and between opposite loading directions. A database of 170 masonry shear walls was used to evaluate international standards and analytical models. Prediction accuracy generally improved when the horizontal reinforcement contribution was reduced or neglected for partially grouted walls. Mohr-Coulomb based methods and models that considered grouted and ungrouted masonry separately provided the most accurate predictions. A modified equation is proposed to estimate the shear resistance of both partially and fully grouted concrete masonry walls."]},{"key":"dc:title","label":"Title","values":["Investigation on the Shear Strength and Capacity of Concrete Block Masonry"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Shrive, Nigel Graham"],"dc:contributor.committeemember":["El-Hacha, Raafat","Wong, Ron Chik-Kwong","Mehta, Sudarshan A.","Liu, Yi"],"dc:creator":["Zhu, Jianyixian"],"dc:date":["2026-11"],"dc:date.accessioned":["2026-09-17T19:00:56Z"],"dc:date.issued":["2026-09-14"],"dc:description.abstract":["Partially grouted concrete masonry shear walls are widely used because they provide a balance between structural performance and construction efficiency. However, the effects of material properties, grouting, and reinforcement on their shear resistance are not fully understood, and existing design methods often provide highly variable predictions. This study investigated the shear behaviour of concrete block masonry through literature review, material property testing, wall testing, and evaluation of predictive equations. A total of 169 masonry triplet specimens were tested to examine the effects of block condition and strength, grouting location and percentage, specimen configuration, age, and axial compression. The results supported the application of a Mohr-Coulomb criterion to hollow concrete block masonry. Unit compressive strength, grouting location, and specimen configuration had limited effects, while increasing grouting percentage and axial compression improved shear strength. The shear strength of partially grouted specimens could be estimated from the corresponding non-grouted and fully grouted specimens. Fifteen full-scale partially grouted masonry walls were tested under cyclic lateral loading to separate the effects of the grout in the bond beams from those of the horizontal reinforcement. Compared to grouting, the horizontal reinforcement produced only a limited increase in peak shear resistance. However, the presence of steel improved crack distribution, wall integrity, and post-peak behaviour. The wall tests also demonstrated considerable variability among similar specimens and between opposite loading directions. A database of 170 masonry shear walls was used to evaluate international standards and analytical models. Prediction accuracy generally improved when the horizontal reinforcement contribution was reduced or neglected for partially grouted walls. Mohr-Coulomb based methods and models that considered grouted and ungrouted masonry separately provided the most accurate predictions. A modified equation is proposed to estimate the shear resistance of both partially and fully grouted concrete masonry walls."],"dc:identifier.citation":["Zhu, J. (2026). Investigation on the shear strength and capacity of concrete block masonry (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/52032"],"dc:identifier.uri":["https://hdl.handle.net/1880/126105"],"dc:language.iso":["en"],"dc:publisher.faculty":["Schulich School of Engineering"],"dc:rights":["Unless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject.classification":["Engineering--Civil"],"dc:title":["Investigation on the Shear Strength and Capacity of Concrete Block Masonry"],"dc:type":["doctoral thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering – Civil"],"thesis:degree_name":["Doctor of Philosophy (PhD)"],"thesis:institution_name":["University of Calgary"],"thesis:release_request":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]},"updated_at":"2026-11-19T07:11:15Z"}