{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:1880/126119"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:1880/126119","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"One Size Fits All: Automatic Segmentation of Multimodal Haemorrhagic Transformation Scans","abstract":"Haemorrhagic transformation (HT) is a complication of ischaemic stroke that can worsen patient out-comes. HTs can occur even when patients have received appropriate treatment and can only be seen on follow-up imaging. Information on the volume and surface area of HTs can be obtained via manual segmentation. However, due to the time-intensive nature of manual segmentation, it is typically not performed in clinical settings and research that is not directly related to HT volume. This thesis examines the current limitations of existing machine learning (ML) models in stroke treatment and investigates the feasibility of a modality-agnostic (MA) segmentation model for HTs to expediate the segmentation process. The research in this thesis was conducted through two aims. Aim 1 consists of a systematic review of 39 papers and 4 commercially available artificial intelligence (AI) tools for the treatment of acute stroke. The results of Aim 1 found that AI has demonstrated the potential to improve patient outcomes by improving diagnostic accuracy and reducing time-to-treatment, but remains limited by the development of impractical tools, low predictability, and limited documentation of the development and employment of the AI models themselves. Aim 2 comprises two parts: part 1 investigates the effect of preprocessing on the performance of MA segmentation models, and part 2 compares the performance of a single-channel MA segmentation model with single-modality models on the same dataset. The findings in part 1 demonstrated that none of the preprocessing methods evaluated had a significant effect on model performance. Additionally, they suggest that the MA models do not depend on fine details for making predictions, and remain unaffected by high-frequency noise in scans. Part 2’s findings support the feasibility of MA segmentation models for HT, and demonstrate that MA models can perform similarly to single-modality models without increased bias towards sensitive attributes, like sex and weight. Altogether, the results of this thesis find that there is a disconnect between research and usable appli-cations of ML, and illustrates that it is feasible to develop an MA segmentation model for HT that can be applied to non-uniform, real-world data. It provides foundational research on automatic segmentation of HT and the potential of single-channel MA segmentation models in stroke imaging.","abstract_html":"Haemorrhagic transformation (HT) is a complication of ischaemic stroke that can worsen patient out-comes. HTs can occur even when patients have received appropriate treatment and can only be seen on follow-up imaging. Information on the volume and surface area of HTs can be obtained via manual segmentation. However, due to the time-intensive nature of manual segmentation, it is typically not performed in clinical settings and research that is not directly related to HT volume. This thesis examines the current limitations of existing machine learning (ML) models in stroke treatment and investigates the feasibility of a modality-agnostic (MA) segmentation model for HTs to expediate the segmentation process. The research in this thesis was conducted through two aims. Aim 1 consists of a systematic review of 39 papers and 4 commercially available artificial intelligence (AI) tools for the treatment of acute stroke. The results of Aim 1 found that AI has demonstrated the potential to improve patient outcomes by improving diagnostic accuracy and reducing time-to-treatment, but remains limited by the development of impractical tools, low predictability, and limited documentation of the development and employment of the AI models themselves. Aim 2 comprises two parts: part 1 investigates the effect of preprocessing on the performance of MA segmentation models, and part 2 compares the performance of a single-channel MA segmentation model with single-modality models on the same dataset. The findings in part 1 demonstrated that none of the preprocessing methods evaluated had a significant effect on model performance. Additionally, they suggest that the MA models do not depend on fine details for making predictions, and remain unaffected by high-frequency noise in scans. Part 2’s findings support the feasibility of MA segmentation models for HT, and demonstrate that MA models can perform similarly to single-modality models without increased bias towards sensitive attributes, like sex and weight. Altogether, the results of this thesis find that there is a disconnect between research and usable appli-cations of ML, and illustrates that it is feasible to develop an MA segmentation model for HT that can be applied to non-uniform, real-world data. It provides foundational research on automatic segmentation of HT and the potential of single-channel MA segmentation models in stroke imaging.","abstract_has_math":false,"creators":["Kindleman, Brooke"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Engineering – Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":["Pinheiro Bento, Mariana"],"committee_chairs":[],"committee_members":["Ospel, Johanna","Frayne, Richard"],"year":2026,"date_issued":"2026-09-10","date_published":"2026-09-10","updated_at":"2026-11-19T07:24:42Z","subjects":["Haemorrhagic transformation","Stroke","Semantic segmentation","Machine learning","Artificial intelligence","Computed tomography","Magnetic resonance imaging","Diagnostic imaging"],"languages":["en"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/126119"],"render_values":[{"text":"https://hdl.handle.net/1880/126119","href":"https://hdl.handle.net/1880/126119","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Kindleman, B. (2026). One size fits all: automatic segmentation of multimodalhaemorrhagic transformation scans (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"render_values":[{"text":"Kindleman, B. (2026). One size fits all: automatic segmentation of multimodalhaemorrhagic transformation scans (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/52043","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/52043","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A1880%2F126119","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A1880%2F126119","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Pinheiro Bento, Mariana"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ospel, Johanna","Frayne, Richard"]},{"key":"dc:creator","label":"Author","values":["Kindleman, Brooke"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-21T15:00:05Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-09-10"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering – Biomedical"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]},{"key":"thesis:release_request","label":"Thesis Release Request","values":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Haemorrhagic transformation","Stroke","Semantic segmentation","Machine learning","Artificial intelligence","Computed tomography","Magnetic resonance imaging","Diagnostic imaging"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Artificial Intelligence","Engineering--Biomedical","Biophysics--Medical","Radiology","Computer Science","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Kindleman, B. (2026). One size fits all: automatic segmentation of multimodalhaemorrhagic transformation scans (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."]},{"key":"dc:identifier.doi","label":"DOI","values":["https://dx.doi.org/10.11575/PRISM/52043"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1880/126119"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Haemorrhagic transformation (HT) is a complication of ischaemic stroke that can worsen patient out-comes. HTs can occur even when patients have received appropriate treatment and can only be seen on follow-up imaging. Information on the volume and surface area of HTs can be obtained via manual segmentation. However, due to the time-intensive nature of manual segmentation, it is typically not performed in clinical settings and research that is not directly related to HT volume. This thesis examines the current limitations of existing machine learning (ML) models in stroke treatment and investigates the feasibility of a modality-agnostic (MA) segmentation model for HTs to expediate the segmentation process. The research in this thesis was conducted through two aims. Aim 1 consists of a systematic review of 39 papers and 4 commercially available artificial intelligence (AI) tools for the treatment of acute stroke. The results of Aim 1 found that AI has demonstrated the potential to improve patient outcomes by improving diagnostic accuracy and reducing time-to-treatment, but remains limited by the development of impractical tools, low predictability, and limited documentation of the development and employment of the AI models themselves. Aim 2 comprises two parts: part 1 investigates the effect of preprocessing on the performance of MA segmentation models, and part 2 compares the performance of a single-channel MA segmentation model with single-modality models on the same dataset. The findings in part 1 demonstrated that none of the preprocessing methods evaluated had a significant effect on model performance. Additionally, they suggest that the MA models do not depend on fine details for making predictions, and remain unaffected by high-frequency noise in scans. Part 2’s findings support the feasibility of MA segmentation models for HT, and demonstrate that MA models can perform similarly to single-modality models without increased bias towards sensitive attributes, like sex and weight. Altogether, the results of this thesis find that there is a disconnect between research and usable appli-cations of ML, and illustrates that it is feasible to develop an MA segmentation model for HT that can be applied to non-uniform, real-world data. It provides foundational research on automatic segmentation of HT and the potential of single-channel MA segmentation models in stroke imaging."]},{"key":"dc:title","label":"Title","values":["One Size Fits All: Automatic Segmentation of Multimodal Haemorrhagic Transformation Scans"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Pinheiro Bento, Mariana"],"dc:contributor.committeemember":["Ospel, Johanna","Frayne, Richard"],"dc:creator":["Kindleman, Brooke"],"dc:date":["2026-11"],"dc:date.accessioned":["2026-09-21T15:00:05Z"],"dc:date.issued":["2026-09-10"],"dc:description.abstract":["Haemorrhagic transformation (HT) is a complication of ischaemic stroke that can worsen patient out-comes. HTs can occur even when patients have received appropriate treatment and can only be seen on follow-up imaging. Information on the volume and surface area of HTs can be obtained via manual segmentation. However, due to the time-intensive nature of manual segmentation, it is typically not performed in clinical settings and research that is not directly related to HT volume. This thesis examines the current limitations of existing machine learning (ML) models in stroke treatment and investigates the feasibility of a modality-agnostic (MA) segmentation model for HTs to expediate the segmentation process. The research in this thesis was conducted through two aims. Aim 1 consists of a systematic review of 39 papers and 4 commercially available artificial intelligence (AI) tools for the treatment of acute stroke. The results of Aim 1 found that AI has demonstrated the potential to improve patient outcomes by improving diagnostic accuracy and reducing time-to-treatment, but remains limited by the development of impractical tools, low predictability, and limited documentation of the development and employment of the AI models themselves. Aim 2 comprises two parts: part 1 investigates the effect of preprocessing on the performance of MA segmentation models, and part 2 compares the performance of a single-channel MA segmentation model with single-modality models on the same dataset. The findings in part 1 demonstrated that none of the preprocessing methods evaluated had a significant effect on model performance. Additionally, they suggest that the MA models do not depend on fine details for making predictions, and remain unaffected by high-frequency noise in scans. Part 2’s findings support the feasibility of MA segmentation models for HT, and demonstrate that MA models can perform similarly to single-modality models without increased bias towards sensitive attributes, like sex and weight. Altogether, the results of this thesis find that there is a disconnect between research and usable appli-cations of ML, and illustrates that it is feasible to develop an MA segmentation model for HT that can be applied to non-uniform, real-world data. It provides foundational research on automatic segmentation of HT and the potential of single-channel MA segmentation models in stroke imaging."],"dc:identifier.citation":["Kindleman, B. (2026). One size fits all: automatic segmentation of multimodalhaemorrhagic transformation scans (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca."],"dc:identifier.doi":["https://dx.doi.org/10.11575/PRISM/52043"],"dc:identifier.uri":["https://hdl.handle.net/1880/126119"],"dc:language.iso":["en"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Haemorrhagic transformation","Stroke","Semantic segmentation","Machine learning","Artificial intelligence","Computed tomography","Magnetic resonance imaging","Diagnostic imaging"],"dc:subject.classification":["Artificial Intelligence","Engineering--Biomedical","Biophysics--Medical","Radiology","Computer Science","Engineering"],"dc:title":["One Size Fits All: Automatic Segmentation of Multimodal Haemorrhagic Transformation Scans"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering – Biomedical"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"],"thesis:release_request":["I do not require a thesis withhold – my thesis will have open access and can be viewed and downloaded publicly as soon as possible."]},"updated_at":"2026-11-19T07:24:42Z"}