{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-1200"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-1200","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Time-Frequency Analysis of Intracardiac Electrogram","abstract":"The Cardiac Rhythm Management Division of St. Jude Medical specializes in the development of implantable cardioverter defibrillators that improve the quality of life for patients diagnosed with a variety of cardiac arrhythmias, especially for patients prone to sudden cardiac death. With the goal to improve detection of cardiac arrhythmias, this study explored the value in time-frequency analysis of intracardiac electrogram in four steps. The first two steps characterized, in the frequency domain, the waveforms that construct the cardiac cycle. The third step developed a new algorithm that putatively provides the least computationally expensive way to identifying cardiac waveforms in the frequency domain. Lastly, this novel approach to analyzing intracardiac electrogram was compared to a threshold crossing algorithm that strictly operates in the time domain and that is currently utilized by St. Jude Medical. The new algorithm demonstrated an equally effective method in identifying the QRS complex on the ventricular channel. The next steps in pursing time-frequency analysis of intracardiac electrogram include implementing the new algorithm on a testing platform that emulates the latest implantable cardioverter defibrillator manufactured by St. Jude Medical and pursuing a similar algorithm that can be employed on the atrial channel.","abstract_html":"The Cardiac Rhythm Management Division of St. Jude Medical specializes in the development of implantable cardioverter defibrillators that improve the quality of life for patients diagnosed with a variety of cardiac arrhythmias, especially for patients prone to sudden cardiac death. With the goal to improve detection of cardiac arrhythmias, this study explored the value in time-frequency analysis of intracardiac electrogram in four steps. The first two steps characterized, in the frequency domain, the waveforms that construct the cardiac cycle. The third step developed a new algorithm that putatively provides the least computationally expensive way to identifying cardiac waveforms in the frequency domain. Lastly, this novel approach to analyzing intracardiac electrogram was compared to a threshold crossing algorithm that strictly operates in the time domain and that is currently utilized by St. Jude Medical. The new algorithm demonstrated an equally effective method in identifying the QRS complex on the ventricular channel. The next steps in pursing time-frequency analysis of intracardiac electrogram include implementing the new algorithm on a testing platform that emulates the latest implantable cardioverter defibrillator manufactured by St. Jude Medical and pursuing a similar algorithm that can be employed on the atrial channel.","abstract_has_math":false,"creators":["Brockman, Erik"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":"Biomedical and General Engineering","degree_department":null,"school":null,"contributors":["Lily Laiho"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:10:55Z","subjects":["Time-Frequency","Intracardiac Electrogram","QRS Complex","Cardiac Arrhythmia","Frequency Domain","Time Domain","Bioelectrical and Neuroengineering","Biomedical","Biomedical Devices and Instrumentation","Other Biomedical Engineering and Bioengineering","Other Electrical and Computer Engineering","Signal Processing"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.15368/theses.2009.97"],"render_values":[{"text":"10.15368/theses.2009.97","href":"https://doi.org/10.15368/theses.2009.97","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/188","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/188","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-1200","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Lily Laiho"]},{"key":"dc:creator","label":"Author","values":["Brockman, Erik"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2011-11-18T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2009-06-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical and General Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Time-Frequency","Intracardiac Electrogram","QRS Complex","Cardiac Arrhythmia","Frequency Domain","Time Domain","Bioelectrical and Neuroengineering","Biomedical","Biomedical Devices and Instrumentation","Other Biomedical Engineering and Bioengineering","Other Electrical and Computer Engineering","Signal Processing"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/188","10.15368/theses.2009.97"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Cardiac Rhythm Management Division of St. Jude Medical specializes in the development of implantable cardioverter defibrillators that improve the quality of life for patients diagnosed with a variety of cardiac arrhythmias, especially for patients prone to sudden cardiac death. With the goal to improve detection of cardiac arrhythmias, this study explored the value in time-frequency analysis of intracardiac electrogram in four steps. The first two steps characterized, in the frequency domain, the waveforms that construct the cardiac cycle. The third step developed a new algorithm that putatively provides the least computationally expensive way to identifying cardiac waveforms in the frequency domain. Lastly, this novel approach to analyzing intracardiac electrogram was compared to a threshold crossing algorithm that strictly operates in the time domain and that is currently utilized by St. Jude Medical. The new algorithm demonstrated an equally effective method in identifying the QRS complex on the ventricular channel. The next steps in pursing time-frequency analysis of intracardiac electrogram include implementing the new algorithm on a testing platform that emulates the latest implantable cardioverter defibrillator manufactured by St. Jude Medical and pursuing a similar algorithm that can be employed on the atrial channel."]},{"key":"dc:title","label":"Title","values":["Time-Frequency Analysis of Intracardiac Electrogram"]}]}],"canonical_facts":{"dc:contributor":["Lily Laiho"],"dc:creator":["Brockman, Erik"],"dc:date.available":["2011-11-18T08:00:00Z"],"dc:date.created":["2009-06-01T07:00:00Z"],"dc:description.abstract":["The Cardiac Rhythm Management Division of St. Jude Medical specializes in the development of implantable cardioverter defibrillators that improve the quality of life for patients diagnosed with a variety of cardiac arrhythmias, especially for patients prone to sudden cardiac death. With the goal to improve detection of cardiac arrhythmias, this study explored the value in time-frequency analysis of intracardiac electrogram in four steps. The first two steps characterized, in the frequency domain, the waveforms that construct the cardiac cycle. The third step developed a new algorithm that putatively provides the least computationally expensive way to identifying cardiac waveforms in the frequency domain. Lastly, this novel approach to analyzing intracardiac electrogram was compared to a threshold crossing algorithm that strictly operates in the time domain and that is currently utilized by St. Jude Medical. The new algorithm demonstrated an equally effective method in identifying the QRS complex on the ventricular channel. The next steps in pursing time-frequency analysis of intracardiac electrogram include implementing the new algorithm on a testing platform that emulates the latest implantable cardioverter defibrillator manufactured by St. Jude Medical and pursuing a similar algorithm that can be employed on the atrial channel."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/188","10.15368/theses.2009.97"],"dc:subject":["Time-Frequency","Intracardiac Electrogram","QRS Complex","Cardiac Arrhythmia","Frequency Domain","Time Domain","Bioelectrical and Neuroengineering","Biomedical","Biomedical Devices and Instrumentation","Other Biomedical Engineering and Bioengineering","Other Electrical and Computer Engineering","Signal Processing"],"dc:title":["Time-Frequency Analysis of Intracardiac Electrogram"],"thesis:degree_discipline":["Biomedical and General Engineering"]},"updated_at":"2026-11-19T07:10:55Z"}