{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-1383"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-1383","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Integration of Microfluidics with Surface Plasmon Resonance","abstract":"This thesis successfully integrates laminate microfluidic devices with an analytic Surface Plasmon Resonance (SPR) instrument. Integration was accomplished at low-cost using materials such as polydimethylsiloxane (PDMS), Poly(methyl methacrylate) (PMMA), Tygon tubing, and a 3-way stopcock. The main components of this thesis are the design and fabrication of the low-cost, in-house fluidics that can integrate with upstream microfluidics and the validation of the in-house fluidics using the Biosensing Instruments BI-2000 SPR instrument. The low-cost fluidics was designed and fabricated “in-house” using a novel investment casting technique that required the use of laser cutting technology to make a master cast, and candle wax to make the fluidic flow gasket. Integration of upstream microfluidic devices is the next step towards fully integrated point-of-care (POC) diagnostics. Development of low-cost POC diagnostics will enable physicians to diagnosis patients outside of clinical settings, granting treatment access to a much wider population. Surface Plasmon Resonance is used for its detection abilities combined with its ability to perform real-time sample analysis. Validation of the in-house fluidics was accomplished by conducting (2) experiments: (1) to compare the angular shift elicited by ethanol solutions between in-house fluidics, factory fluidics, and the literature, and (2) to compare the angular shift between in-house fluidics and factory fluidics caused by the cleaving of fibroblasts from the SPR sensor chip. Successful comparisons made in both experiments proved successful development of low-cost fluidics that could integrate upstream microfluidic devices.","abstract_html":"This thesis successfully integrates laminate microfluidic devices with an analytic Surface Plasmon Resonance (SPR) instrument. Integration was accomplished at low-cost using materials such as polydimethylsiloxane (PDMS), Poly(methyl methacrylate) (PMMA), Tygon tubing, and a 3-way stopcock. The main components of this thesis are the design and fabrication of the low-cost, in-house fluidics that can integrate with upstream microfluidics and the validation of the in-house fluidics using the Biosensing Instruments BI-2000 SPR instrument. The low-cost fluidics was designed and fabricated “in-house” using a novel investment casting technique that required the use of laser cutting technology to make a master cast, and candle wax to make the fluidic flow gasket. Integration of upstream microfluidic devices is the next step towards fully integrated point-of-care (POC) diagnostics. Development of low-cost POC diagnostics will enable physicians to diagnosis patients outside of clinical settings, granting treatment access to a much wider population. Surface Plasmon Resonance is used for its detection abilities combined with its ability to perform real-time sample analysis. Validation of the in-house fluidics was accomplished by conducting (2) experiments: (1) to compare the angular shift elicited by ethanol solutions between in-house fluidics, factory fluidics, and the literature, and (2) to compare the angular shift between in-house fluidics and factory fluidics caused by the cleaving of fibroblasts from the SPR sensor chip. Successful comparisons made in both experiments proved successful development of low-cost fluidics that could integrate upstream microfluidic devices.","abstract_has_math":false,"creators":["Fratzke, Scott B"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":"Biomedical and General Engineering","degree_department":null,"school":null,"contributors":["David Clague"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:11:02Z","subjects":["Surface Plasmon Resonance","Microfluidics","Ethanol","Fibroblasts","Point-of-Care","Biomechanics and Biotransport","Systems and Integrative Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.15368/theses.2010.133"],"render_values":[{"text":"10.15368/theses.2010.133","href":"https://doi.org/10.15368/theses.2010.133","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/366","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/366","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-1383","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["David Clague"]},{"key":"dc:creator","label":"Author","values":["Fratzke, Scott B"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-08-05T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2010-08-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical and General Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Surface Plasmon Resonance","Microfluidics","Ethanol","Fibroblasts","Point-of-Care","Biomechanics and Biotransport","Systems and Integrative Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/366","10.15368/theses.2010.133"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis successfully integrates laminate microfluidic devices with an analytic Surface Plasmon Resonance (SPR) instrument. Integration was accomplished at low-cost using materials such as polydimethylsiloxane (PDMS), Poly(methyl methacrylate) (PMMA), Tygon tubing, and a 3-way stopcock. The main components of this thesis are the design and fabrication of the low-cost, in-house fluidics that can integrate with upstream microfluidics and the validation of the in-house fluidics using the Biosensing Instruments BI-2000 SPR instrument. The low-cost fluidics was designed and fabricated “in-house” using a novel investment casting technique that required the use of laser cutting technology to make a master cast, and candle wax to make the fluidic flow gasket. Integration of upstream microfluidic devices is the next step towards fully integrated point-of-care (POC) diagnostics. Development of low-cost POC diagnostics will enable physicians to diagnosis patients outside of clinical settings, granting treatment access to a much wider population. Surface Plasmon Resonance is used for its detection abilities combined with its ability to perform real-time sample analysis. Validation of the in-house fluidics was accomplished by conducting (2) experiments: (1) to compare the angular shift elicited by ethanol solutions between in-house fluidics, factory fluidics, and the literature, and (2) to compare the angular shift between in-house fluidics and factory fluidics caused by the cleaving of fibroblasts from the SPR sensor chip. Successful comparisons made in both experiments proved successful development of low-cost fluidics that could integrate upstream microfluidic devices."]},{"key":"dc:title","label":"Title","values":["Integration of Microfluidics with Surface Plasmon Resonance"]}]}],"canonical_facts":{"dc:contributor":["David Clague"],"dc:creator":["Fratzke, Scott B"],"dc:date.available":["2010-08-05T07:00:00Z"],"dc:date.created":["2010-08-01T07:00:00Z"],"dc:description.abstract":["This thesis successfully integrates laminate microfluidic devices with an analytic Surface Plasmon Resonance (SPR) instrument. Integration was accomplished at low-cost using materials such as polydimethylsiloxane (PDMS), Poly(methyl methacrylate) (PMMA), Tygon tubing, and a 3-way stopcock. The main components of this thesis are the design and fabrication of the low-cost, in-house fluidics that can integrate with upstream microfluidics and the validation of the in-house fluidics using the Biosensing Instruments BI-2000 SPR instrument. The low-cost fluidics was designed and fabricated “in-house” using a novel investment casting technique that required the use of laser cutting technology to make a master cast, and candle wax to make the fluidic flow gasket. Integration of upstream microfluidic devices is the next step towards fully integrated point-of-care (POC) diagnostics. Development of low-cost POC diagnostics will enable physicians to diagnosis patients outside of clinical settings, granting treatment access to a much wider population. Surface Plasmon Resonance is used for its detection abilities combined with its ability to perform real-time sample analysis. Validation of the in-house fluidics was accomplished by conducting (2) experiments: (1) to compare the angular shift elicited by ethanol solutions between in-house fluidics, factory fluidics, and the literature, and (2) to compare the angular shift between in-house fluidics and factory fluidics caused by the cleaving of fibroblasts from the SPR sensor chip. Successful comparisons made in both experiments proved successful development of low-cost fluidics that could integrate upstream microfluidic devices."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/366","10.15368/theses.2010.133"],"dc:subject":["Surface Plasmon Resonance","Microfluidics","Ethanol","Fibroblasts","Point-of-Care","Biomechanics and Biotransport","Systems and Integrative Engineering"],"dc:title":["Integration of Microfluidics with Surface Plasmon Resonance"],"thesis:degree_discipline":["Biomedical and General Engineering"]},"updated_at":"2026-11-19T07:11:02Z"}