{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-1757"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-1757","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Performance Based Analysis of a Steel Braced Frame Building with Buckling Restrained Braces","abstract":"This paper provides an assessment of the seismic performance of a code-designed buckling restrained braced frame building using the performance-based analysis procedures prescribed in ASCE 41-06. The building was designed based on the standards of the ASCE 7-05 for a typical office building located in San Francisco, CA. Nonlinear modeling parameters and acceptance criteria for buckling restrained brace components were developed to match ASCE 41-06 design standards for structural steel components, since buckling restrained braces are not currently included in ASCE 41-06. The building was evaluated using linear static, linear dynamic, nonlinear static and nonlinear dynamic analysis procedures. This study showed that the linear procedures produced more conservative results, with the building performing within the intended Life Safety limit, while the nonlinear procedures predicted that the building performed closer to the Immediate Occupancy limit for the 2/3 maximum considered earthquake hazard. These results apply to the full maximum considered earthquake hazard as well, under which the building performed within the Collapse Prevention limit in the linear analysis results and within the Life Safety limit in the nonlinear analysis results. The results of this paper will provide data for the engineering profession on the behavior of buckling restrained braced frames as well as performance based engineering as it continues to evolve.","abstract_html":"This paper provides an assessment of the seismic performance of a code-designed buckling restrained braced frame building using the performance-based analysis procedures prescribed in ASCE 41-06. The building was designed based on the standards of the ASCE 7-05 for a typical office building located in San Francisco, CA. Nonlinear modeling parameters and acceptance criteria for buckling restrained brace components were developed to match ASCE 41-06 design standards for structural steel components, since buckling restrained braces are not currently included in ASCE 41-06. The building was evaluated using linear static, linear dynamic, nonlinear static and nonlinear dynamic analysis procedures. This study showed that the linear procedures produced more conservative results, with the building performing within the intended Life Safety limit, while the nonlinear procedures predicted that the building performed closer to the Immediate Occupancy limit for the 2/3 maximum considered earthquake hazard. These results apply to the full maximum considered earthquake hazard as well, under which the building performed within the Collapse Prevention limit in the linear analysis results and within the Life Safety limit in the nonlinear analysis results. The results of this paper will provide data for the engineering profession on the behavior of buckling restrained braced frames as well as performance based engineering as it continues to evolve.","abstract_has_math":false,"creators":["Burkholder, Margaux Claire"],"institution":null,"degree_name":"MS in Architecture - Architectural Engineering","degree_level":null,"degree_discipline":"Architecture","degree_department":null,"school":null,"contributors":["Jim Guthrie"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:11:35Z","subjects":["Performance Based Design","Buckling Restrained Braced Frames","BRBF","ASCE 41","Structural Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.15368/theses.2012.33"],"render_values":[{"text":"10.15368/theses.2012.33","href":"https://doi.org/10.15368/theses.2012.33","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/715","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/715","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-1757","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Jim Guthrie"]},{"key":"dc:creator","label":"Author","values":["Burkholder, Margaux Claire"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2012-04-15T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2012-04-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Architecture"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Architecture - Architectural Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Performance Based Design","Buckling Restrained Braced Frames","BRBF","ASCE 41","Structural Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/715","10.15368/theses.2012.33"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This paper provides an assessment of the seismic performance of a code-designed buckling restrained braced frame building using the performance-based analysis procedures prescribed in ASCE 41-06. The building was designed based on the standards of the ASCE 7-05 for a typical office building located in San Francisco, CA. Nonlinear modeling parameters and acceptance criteria for buckling restrained brace components were developed to match ASCE 41-06 design standards for structural steel components, since buckling restrained braces are not currently included in ASCE 41-06. The building was evaluated using linear static, linear dynamic, nonlinear static and nonlinear dynamic analysis procedures. This study showed that the linear procedures produced more conservative results, with the building performing within the intended Life Safety limit, while the nonlinear procedures predicted that the building performed closer to the Immediate Occupancy limit for the 2/3 maximum considered earthquake hazard. These results apply to the full maximum considered earthquake hazard as well, under which the building performed within the Collapse Prevention limit in the linear analysis results and within the Life Safety limit in the nonlinear analysis results. The results of this paper will provide data for the engineering profession on the behavior of buckling restrained braced frames as well as performance based engineering as it continues to evolve."]},{"key":"dc:title","label":"Title","values":["Performance Based Analysis of a Steel Braced Frame Building with Buckling Restrained Braces"]}]}],"canonical_facts":{"dc:contributor":["Jim Guthrie"],"dc:creator":["Burkholder, Margaux Claire"],"dc:date.available":["2012-04-15T07:00:00Z"],"dc:date.created":["2012-04-01T07:00:00Z"],"dc:description.abstract":["This paper provides an assessment of the seismic performance of a code-designed buckling restrained braced frame building using the performance-based analysis procedures prescribed in ASCE 41-06. The building was designed based on the standards of the ASCE 7-05 for a typical office building located in San Francisco, CA. Nonlinear modeling parameters and acceptance criteria for buckling restrained brace components were developed to match ASCE 41-06 design standards for structural steel components, since buckling restrained braces are not currently included in ASCE 41-06. The building was evaluated using linear static, linear dynamic, nonlinear static and nonlinear dynamic analysis procedures. This study showed that the linear procedures produced more conservative results, with the building performing within the intended Life Safety limit, while the nonlinear procedures predicted that the building performed closer to the Immediate Occupancy limit for the 2/3 maximum considered earthquake hazard. These results apply to the full maximum considered earthquake hazard as well, under which the building performed within the Collapse Prevention limit in the linear analysis results and within the Life Safety limit in the nonlinear analysis results. The results of this paper will provide data for the engineering profession on the behavior of buckling restrained braced frames as well as performance based engineering as it continues to evolve."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/715","10.15368/theses.2012.33"],"dc:subject":["Performance Based Design","Buckling Restrained Braced Frames","BRBF","ASCE 41","Structural Engineering"],"dc:title":["Performance Based Analysis of a Steel Braced Frame Building with Buckling Restrained Braces"],"thesis:degree_discipline":["Architecture"],"thesis:degree_name":["MS in Architecture - Architectural Engineering"]},"updated_at":"2026-11-19T07:11:35Z"}