{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-2068"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-2068","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"The Effect of a Triphasic Pulse on SCS to ICD Crosstalk","abstract":"It is a known problem that a Spinal Cord Stimulator (SCS) can interact with an Implantable Cardioverter Defibrillator (ICD) when both devices are implanted in the same patient. Interactions between the SCS and ICD can cause inappropriate therapy which can be harmful to the patient. While ICD devices have a distinct narrowband sensing bandwidth, the pulse configurations that current SCS devices deliver were not designed with this frequency region in mind. In this thesis, I recommend a new pulse configuration for SCS devices that will minimize the interaction between the two devices. I produce a theoretical equation for each pulse configuration in the frequency domain using the Laplace transform and present the results in Matlab. I also design my own SCS device to deliver multiple pulse configurations and use it to gather empirical data. The theoretical and empirical results are used to show the extent of the improvement between the new pulse and existing pulse configurations. The results prove that the new pulse configuration will significantly reduce crosstalk within the desired ICD bandwidth. A reduction in crosstalk will decrease the probability that an SCS will interact with a ICD device.","abstract_html":"It is a known problem that a Spinal Cord Stimulator (SCS) can interact with an Implantable Cardioverter Defibrillator (ICD) when both devices are implanted in the same patient. Interactions between the SCS and ICD can cause inappropriate therapy which can be harmful to the patient. While ICD devices have a distinct narrowband sensing bandwidth, the pulse configurations that current SCS devices deliver were not designed with this frequency region in mind. In this thesis, I recommend a new pulse configuration for SCS devices that will minimize the interaction between the two devices. I produce a theoretical equation for each pulse configuration in the frequency domain using the Laplace transform and present the results in Matlab. I also design my own SCS device to deliver multiple pulse configurations and use it to gather empirical data. The theoretical and empirical results are used to show the extent of the improvement between the new pulse and existing pulse configurations. The results prove that the new pulse configuration will significantly reduce crosstalk within the desired ICD bandwidth. A reduction in crosstalk will decrease the probability that an SCS will interact with a ICD device.","abstract_has_math":false,"creators":["Wensley, Ryan James"],"institution":null,"degree_name":"MS in Biomedical Engineering","degree_level":null,"degree_discipline":"Biomedical and General Engineering","degree_department":null,"school":null,"contributors":["David Clague"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:11:08Z","subjects":["Spinal Cord Stimulator","SCS","Implantable Cardioverter Defibrillator","ICD","Crosstalk","triphasic pulse","Biomedical Devices and Instrumentation"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.15368/theses.2013.141"],"render_values":[{"text":"10.15368/theses.2013.141","href":"https://doi.org/10.15368/theses.2013.141","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/993","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/993","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-2068","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["David Clague"]},{"key":"dc:creator","label":"Author","values":["Wensley, Ryan James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2013-07-26T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2013-06-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical and General Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Spinal Cord Stimulator","SCS","Implantable Cardioverter Defibrillator","ICD","Crosstalk","triphasic pulse","Biomedical Devices and Instrumentation"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/993","10.15368/theses.2013.141"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["It is a known problem that a Spinal Cord Stimulator (SCS) can interact with an Implantable Cardioverter Defibrillator (ICD) when both devices are implanted in the same patient. Interactions between the SCS and ICD can cause inappropriate therapy which can be harmful to the patient. While ICD devices have a distinct narrowband sensing bandwidth, the pulse configurations that current SCS devices deliver were not designed with this frequency region in mind. In this thesis, I recommend a new pulse configuration for SCS devices that will minimize the interaction between the two devices. I produce a theoretical equation for each pulse configuration in the frequency domain using the Laplace transform and present the results in Matlab. I also design my own SCS device to deliver multiple pulse configurations and use it to gather empirical data. The theoretical and empirical results are used to show the extent of the improvement between the new pulse and existing pulse configurations. The results prove that the new pulse configuration will significantly reduce crosstalk within the desired ICD bandwidth. A reduction in crosstalk will decrease the probability that an SCS will interact with a ICD device."]},{"key":"dc:title","label":"Title","values":["The Effect of a Triphasic Pulse on SCS to ICD Crosstalk"]}]}],"canonical_facts":{"dc:contributor":["David Clague"],"dc:creator":["Wensley, Ryan James"],"dc:date.available":["2013-07-26T07:00:00Z"],"dc:date.created":["2013-06-01T07:00:00Z"],"dc:description.abstract":["It is a known problem that a Spinal Cord Stimulator (SCS) can interact with an Implantable Cardioverter Defibrillator (ICD) when both devices are implanted in the same patient. Interactions between the SCS and ICD can cause inappropriate therapy which can be harmful to the patient. While ICD devices have a distinct narrowband sensing bandwidth, the pulse configurations that current SCS devices deliver were not designed with this frequency region in mind. In this thesis, I recommend a new pulse configuration for SCS devices that will minimize the interaction between the two devices. I produce a theoretical equation for each pulse configuration in the frequency domain using the Laplace transform and present the results in Matlab. I also design my own SCS device to deliver multiple pulse configurations and use it to gather empirical data. The theoretical and empirical results are used to show the extent of the improvement between the new pulse and existing pulse configurations. The results prove that the new pulse configuration will significantly reduce crosstalk within the desired ICD bandwidth. A reduction in crosstalk will decrease the probability that an SCS will interact with a ICD device."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/993","10.15368/theses.2013.141"],"dc:subject":["Spinal Cord Stimulator","SCS","Implantable Cardioverter Defibrillator","ICD","Crosstalk","triphasic pulse","Biomedical Devices and Instrumentation"],"dc:title":["The Effect of a Triphasic Pulse on SCS to ICD Crosstalk"],"thesis:degree_discipline":["Biomedical and General Engineering"],"thesis:degree_name":["MS in Biomedical Engineering"]},"updated_at":"2026-11-19T07:11:08Z"}