{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-2217"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-2217","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Development and Validation of a Human Knee Joint Finite Element Model for Tissue Stress and Strain Predictions During Exercise","abstract":"Osteoarthritis (OA) is a degenerative condition of cartilage and is the leading cost of disability in the United States. Motion analysis experiments in combination with knee-joint finite element (FE) analysis may be used to identify exercises that maintain knee-joint osteochondral (OC) loading at safe levels for patients at high-risk for knee OA, individuals with modest OC defects, or patients rehabilitating after surgical interventions. Therefore, a detailed total knee-joint FE model was developed by modifying open-source knee-joint geometries in order to predict OC tissue stress and strain during the stance phase of gait. The model was partially validated for predicting the timing and locations of maximum contact parameters (contact pressure, contact area, and principal Green-Lagrangian strain), but over-estimated contact parameters compared with both published in vivo studies and other FE analyses of the stance phase of gait. This suggests that the model geometry and kinematic boundary conditions utilized in this FE model are appropriate, but limitations in the material properties used, as well as potentially the loading boundary conditions represent primary areas for improvement.","abstract_html":"Osteoarthritis (OA) is a degenerative condition of cartilage and is the leading cost of disability in the United States. Motion analysis experiments in combination with knee-joint finite element (FE) analysis may be used to identify exercises that maintain knee-joint osteochondral (OC) loading at safe levels for patients at high-risk for knee OA, individuals with modest OC defects, or patients rehabilitating after surgical interventions. Therefore, a detailed total knee-joint FE model was developed by modifying open-source knee-joint geometries in order to predict OC tissue stress and strain during the stance phase of gait. The model was partially validated for predicting the timing and locations of maximum contact parameters (contact pressure, contact area, and principal Green-Lagrangian strain), but over-estimated contact parameters compared with both published in vivo studies and other FE analyses of the stance phase of gait. This suggests that the model geometry and kinematic boundary conditions utilized in this FE model are appropriate, but limitations in the material properties used, as well as potentially the loading boundary conditions represent primary areas for improvement.","abstract_has_math":false,"creators":["Wangerin, Spencer D"],"institution":null,"degree_name":"MS in Mechanical Engineering","degree_level":null,"degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Stephen Klisch"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:11:35Z","subjects":["Osteoarthritis","biomechanics","finite element","motion capture","articular cartilage","stance phase of gait","Biomechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.15368/theses.2013.209"],"render_values":[{"text":"10.15368/theses.2013.209","href":"https://doi.org/10.15368/theses.2013.209","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/1129","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/1129","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-2217","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Stephen Klisch"]},{"key":"dc:creator","label":"Author","values":["Wangerin, Spencer D"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2013-12-13T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2013-12-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Mechanical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Osteoarthritis","biomechanics","finite element","motion capture","articular cartilage","stance phase of gait","Biomechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/1129","10.15368/theses.2013.209"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Osteoarthritis (OA) is a degenerative condition of cartilage and is the leading cost of disability in the United States. Motion analysis experiments in combination with knee-joint finite element (FE) analysis may be used to identify exercises that maintain knee-joint osteochondral (OC) loading at safe levels for patients at high-risk for knee OA, individuals with modest OC defects, or patients rehabilitating after surgical interventions. Therefore, a detailed total knee-joint FE model was developed by modifying open-source knee-joint geometries in order to predict OC tissue stress and strain during the stance phase of gait. The model was partially validated for predicting the timing and locations of maximum contact parameters (contact pressure, contact area, and principal Green-Lagrangian strain), but over-estimated contact parameters compared with both published in vivo studies and other FE analyses of the stance phase of gait. This suggests that the model geometry and kinematic boundary conditions utilized in this FE model are appropriate, but limitations in the material properties used, as well as potentially the loading boundary conditions represent primary areas for improvement."]},{"key":"dc:title","label":"Title","values":["Development and Validation of a Human Knee Joint Finite Element Model for Tissue Stress and Strain Predictions During Exercise"]}]}],"canonical_facts":{"dc:contributor":["Stephen Klisch"],"dc:creator":["Wangerin, Spencer D"],"dc:date.available":["2013-12-13T08:00:00Z"],"dc:date.created":["2013-12-01T08:00:00Z"],"dc:description.abstract":["Osteoarthritis (OA) is a degenerative condition of cartilage and is the leading cost of disability in the United States. Motion analysis experiments in combination with knee-joint finite element (FE) analysis may be used to identify exercises that maintain knee-joint osteochondral (OC) loading at safe levels for patients at high-risk for knee OA, individuals with modest OC defects, or patients rehabilitating after surgical interventions. Therefore, a detailed total knee-joint FE model was developed by modifying open-source knee-joint geometries in order to predict OC tissue stress and strain during the stance phase of gait. The model was partially validated for predicting the timing and locations of maximum contact parameters (contact pressure, contact area, and principal Green-Lagrangian strain), but over-estimated contact parameters compared with both published in vivo studies and other FE analyses of the stance phase of gait. This suggests that the model geometry and kinematic boundary conditions utilized in this FE model are appropriate, but limitations in the material properties used, as well as potentially the loading boundary conditions represent primary areas for improvement."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/1129","10.15368/theses.2013.209"],"dc:subject":["Osteoarthritis","biomechanics","finite element","motion capture","articular cartilage","stance phase of gait","Biomechanical Engineering"],"dc:title":["Development and Validation of a Human Knee Joint Finite Element Model for Tissue Stress and Strain Predictions During Exercise"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_name":["MS in Mechanical Engineering"]},"updated_at":"2026-11-19T07:11:35Z"}