{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-3559"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-3559","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Single-Cell Impedance Spectroscopy","abstract":"Impedance spectroscopy (IS) is an important tool for cell detection and characterization in medical and food safety applications. In this thesis, the Cal Poly Bioﬂuidics Lab’s impedance spectroscopy system was re-evaluated and optimized for single-cell impedance spectroscopy. To evaluate the IS system, an impedance spectroscopy bioMEMS chip was fabricated in the Cal Poly Microfabcrication lab, software was developed to run IS experiments, and studies were run to validate the system. To explore IS optimization, Maxwell’s mixture theorem and the Schwartz-Christoffel transform were used to calculate an analytic impedance solution to the co-planar electrode system,a novel volume fraction to account for the non-uniformity of the electric ﬁeld was developed to increase the accuracy of the analytic solution and to investigate the effect of cell position on the impedance spectrum, a software program was created to allow easy access to the analytic solution, and FEA models were developed to compare to the analytic solution and to investigate the effect of complex device geometry.","abstract_html":"Impedance spectroscopy (IS) is an important tool for cell detection and characterization in medical and food safety applications. In this thesis, the Cal Poly Bioﬂuidics Lab’s impedance spectroscopy system was re-evaluated and optimized for single-cell impedance spectroscopy. To evaluate the IS system, an impedance spectroscopy bioMEMS chip was fabricated in the Cal Poly Microfabcrication lab, software was developed to run IS experiments, and studies were run to validate the system. To explore IS optimization, Maxwell’s mixture theorem and the Schwartz-Christoffel transform were used to calculate an analytic impedance solution to the co-planar electrode system,a novel volume fraction to account for the non-uniformity of the electric ﬁeld was developed to increase the accuracy of the analytic solution and to investigate the effect of cell position on the impedance spectrum, a software program was created to allow easy access to the analytic solution, and FEA models were developed to compare to the analytic solution and to investigate the effect of complex device geometry.","abstract_has_math":false,"creators":["Lange, David Paul"],"institution":null,"degree_name":"MS in Biomedical Engineering","degree_level":null,"degree_discipline":"Biomedical and General Engineering","degree_department":null,"school":null,"contributors":["David Clague","Biomedical and General Engineering","College of Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:11:02Z","subjects":["Impedance Spectroscopy","MEMs","Corrected Maxwells Mixture","Diagnostics","FEA","Optimization","Bioelectrical and Neuroengineering","Biomedical Devices and Instrumentation","Other Biomedical Engineering and Bioengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.15368/theses.2019.147"],"render_values":[{"text":"10.15368/theses.2019.147","href":"https://doi.org/10.15368/theses.2019.147","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/2546","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/2546","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-3559","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["David Clague","Biomedical and General Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Lange, David Paul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2020-12-12T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-12-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical and General Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Impedance Spectroscopy","MEMs","Corrected Maxwells Mixture","Diagnostics","FEA","Optimization","Bioelectrical and Neuroengineering","Biomedical Devices and Instrumentation","Other Biomedical Engineering and Bioengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/2546","10.15368/theses.2019.147"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Impedance spectroscopy (IS) is an important tool for cell detection and characterization in medical and food safety applications. In this thesis, the Cal Poly Bioﬂuidics Lab’s impedance spectroscopy system was re-evaluated and optimized for single-cell impedance spectroscopy. To evaluate the IS system, an impedance spectroscopy bioMEMS chip was fabricated in the Cal Poly Microfabcrication lab, software was developed to run IS experiments, and studies were run to validate the system. To explore IS optimization, Maxwell’s mixture theorem and the Schwartz-Christoffel transform were used to calculate an analytic impedance solution to the co-planar electrode system,a novel volume fraction to account for the non-uniformity of the electric ﬁeld was developed to increase the accuracy of the analytic solution and to investigate the effect of cell position on the impedance spectrum, a software program was created to allow easy access to the analytic solution, and FEA models were developed to compare to the analytic solution and to investigate the effect of complex device geometry."]},{"key":"dc:title","label":"Title","values":["Single-Cell Impedance Spectroscopy"]}]}],"canonical_facts":{"dc:contributor":["David Clague","Biomedical and General Engineering","College of Engineering"],"dc:creator":["Lange, David Paul"],"dc:date.available":["2020-12-12T08:00:00Z"],"dc:date.created":["2019-12-01T08:00:00Z"],"dc:description.abstract":["Impedance spectroscopy (IS) is an important tool for cell detection and characterization in medical and food safety applications. In this thesis, the Cal Poly Bioﬂuidics Lab’s impedance spectroscopy system was re-evaluated and optimized for single-cell impedance spectroscopy. To evaluate the IS system, an impedance spectroscopy bioMEMS chip was fabricated in the Cal Poly Microfabcrication lab, software was developed to run IS experiments, and studies were run to validate the system. To explore IS optimization, Maxwell’s mixture theorem and the Schwartz-Christoffel transform were used to calculate an analytic impedance solution to the co-planar electrode system,a novel volume fraction to account for the non-uniformity of the electric ﬁeld was developed to increase the accuracy of the analytic solution and to investigate the effect of cell position on the impedance spectrum, a software program was created to allow easy access to the analytic solution, and FEA models were developed to compare to the analytic solution and to investigate the effect of complex device geometry."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/2546","10.15368/theses.2019.147"],"dc:subject":["Impedance Spectroscopy","MEMs","Corrected Maxwells Mixture","Diagnostics","FEA","Optimization","Bioelectrical and Neuroengineering","Biomedical Devices and Instrumentation","Other Biomedical Engineering and Bioengineering"],"dc:title":["Single-Cell Impedance Spectroscopy"],"thesis:degree_discipline":["Biomedical and General Engineering"],"thesis:degree_name":["MS in Biomedical Engineering"]},"updated_at":"2026-11-19T07:11:02Z"}