{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-3711"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-3711","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Boost Converter Inductor Sizing Effects on the Performance of MPPT Algorithms","abstract":"With solar power and other renewables set to take over the market in the coming decades, maximum power point tracking will be essential to optimizing power output. One underserved topic of research is the effect of inductor current ripple on performance of Maximum Power Point Tracking (MPPT) algorithms. Many new topologies are focused on decreasing the ripple from PV source to increase efficiency and power output. However, not much has been done to show ripple degrading performance of MPPT algorithms. This study uses a boost converter topology to test the performance of constant duty cycle step Perturb and Observe (PO), Incremental Conductance IC, and Constant Voltage (CV) PID over a range of inductor current ripple factor. Inductor current ripple is controlled solely by changing inductance. This study concluded that all three algorithms were quite robust and affected very little over an inductor current ripple factor range of 20% to 40%. One novel finding was increased duty cycle oscillation when the MPPT update and sample speed was faster than the boost converter response.","abstract_html":"With solar power and other renewables set to take over the market in the coming decades, maximum power point tracking will be essential to optimizing power output. One underserved topic of research is the effect of inductor current ripple on performance of Maximum Power Point Tracking (MPPT) algorithms. Many new topologies are focused on decreasing the ripple from PV source to increase efficiency and power output. However, not much has been done to show ripple degrading performance of MPPT algorithms. This study uses a boost converter topology to test the performance of constant duty cycle step Perturb and Observe (PO), Incremental Conductance IC, and Constant Voltage (CV) PID over a range of inductor current ripple factor. Inductor current ripple is controlled solely by changing inductance. This study concluded that all three algorithms were quite robust and affected very little over an inductor current ripple factor range of 20% to 40%. One novel finding was increased duty cycle oscillation when the MPPT update and sample speed was faster than the boost converter response.","abstract_has_math":false,"creators":["Nonaka, Alan"],"institution":null,"degree_name":"MS in Electrical Engineering","degree_level":null,"degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Taufik","Electrical Engineering","College of Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:11:35Z","subjects":["Inductor Current Ripple","MPPT","PO","IC","CV","Other Electrical and Computer Engineering","Power and Energy"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.15368/theses.2020.128"],"render_values":[{"text":"10.15368/theses.2020.128","href":"https://doi.org/10.15368/theses.2020.128","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/2229","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/2229","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-3711","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Taufik","Electrical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Nonaka, Alan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-09-07T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-08-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Electrical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Inductor Current Ripple","MPPT","PO","IC","CV","Other Electrical and Computer Engineering","Power and Energy"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/2229","10.15368/theses.2020.128"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["With solar power and other renewables set to take over the market in the coming decades, maximum power point tracking will be essential to optimizing power output. One underserved topic of research is the effect of inductor current ripple on performance of Maximum Power Point Tracking (MPPT) algorithms. Many new topologies are focused on decreasing the ripple from PV source to increase efficiency and power output. However, not much has been done to show ripple degrading performance of MPPT algorithms. This study uses a boost converter topology to test the performance of constant duty cycle step Perturb and Observe (PO), Incremental Conductance IC, and Constant Voltage (CV) PID over a range of inductor current ripple factor. Inductor current ripple is controlled solely by changing inductance. This study concluded that all three algorithms were quite robust and affected very little over an inductor current ripple factor range of 20% to 40%. One novel finding was increased duty cycle oscillation when the MPPT update and sample speed was faster than the boost converter response."]},{"key":"dc:title","label":"Title","values":["Boost Converter Inductor Sizing Effects on the Performance of MPPT Algorithms"]}]}],"canonical_facts":{"dc:contributor":["Taufik","Electrical Engineering","College of Engineering"],"dc:creator":["Nonaka, Alan"],"dc:date.available":["2021-09-07T07:00:00Z"],"dc:date.created":["2020-08-01T07:00:00Z"],"dc:description.abstract":["With solar power and other renewables set to take over the market in the coming decades, maximum power point tracking will be essential to optimizing power output. One underserved topic of research is the effect of inductor current ripple on performance of Maximum Power Point Tracking (MPPT) algorithms. Many new topologies are focused on decreasing the ripple from PV source to increase efficiency and power output. However, not much has been done to show ripple degrading performance of MPPT algorithms. This study uses a boost converter topology to test the performance of constant duty cycle step Perturb and Observe (PO), Incremental Conductance IC, and Constant Voltage (CV) PID over a range of inductor current ripple factor. Inductor current ripple is controlled solely by changing inductance. This study concluded that all three algorithms were quite robust and affected very little over an inductor current ripple factor range of 20% to 40%. One novel finding was increased duty cycle oscillation when the MPPT update and sample speed was faster than the boost converter response."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/2229","10.15368/theses.2020.128"],"dc:subject":["Inductor Current Ripple","MPPT","PO","IC","CV","Other Electrical and Computer Engineering","Power and Energy"],"dc:title":["Boost Converter Inductor Sizing Effects on the Performance of MPPT Algorithms"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_name":["MS in Electrical Engineering"]},"updated_at":"2026-11-19T07:11:35Z"}