{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-3721"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-3721","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Dairy Manure Flushwater Treatment by Algae Raceway Ponds and Aerated Biofilm Reactors","abstract":"Nitrogen removal technologies can help dairy industries meet their nutrient management needs. This thesis investigated two separate treatment technologies for total ammonia nitrogen (TAN) removal: algae raceway ponds and aerated biofilm reactors. Six 1000- liter algae raceway ponds and four 1000-liter tote tanks, each equipped with 10 sheets of nonwoven geotextile (i.e., thermally bonded or needle-punched) biofilm substrate, were used to treat the effluent from a flush dairy in central coastal California (TAN = 251 mg/L, cBOD5 = 204 mg/L). For the algae raceway ponds (TAN loading rate = 7 - 35 g/m³-day among 7-, 10- and 14-day hydraulic residence times (HRT)), first-order removal rate constants (k) were ~0.2 day⁻¹ in the summer and 0.1 - 0.2 day⁻¹ in the winter. Removal rate constants had no correlations (R² < 0.1) with water temperature, weak to moderate (for 7-day ponds, R² = 0.55) correlations with insolation and weak to no correlations with biomass (i.e. volatile solids) concentration. During the winter, low insolation likely inhibited algal photosynthesis and biological TAN treatment. Ponds with 7-day HRT had distinct absence of nitrate and nitrite compared to 10- and 14-day ponds. Net productivities were ~20 g/m²-day in summer and 9 – 11 g/m²-day in winter; gross productivities were 120 – 160 g/m²-day in summer and 77 – 150 g/m²-day in winter. Productivities had no correlations (R² < 0.1) with water temperature and weak to moderate correlations (for 14-day ponds, net productivity R² = 0.56, gross productivity R² = 0.83) with insolation. Analysis of organic compounds in pond effluent showed dissolved volatile solids (~2300 mg/L) were mostly non-biodegradable (~98% of soluble oxygen demand). Dissolved organic nitrogen concentrations in the pond effluent were ~35 mg/L. For the aerated biofilm reactors, tanks with needle-punched geotextiles had greater first- order TAN removal rate constants (0.69 day⁻¹) than tanks with thermally bonded geotextiles (0.23 day⁻¹) while operating in batch mode. Needle-punched geotextile reactor also accumulated sludge faster and had higher attached to water column biomass (i.e. volatile solids) ratios (~0.08 g VS/g VS) than thermally bonded geotextile reactor (~0.04 g VS/g VS). Among the four tanks, mass of attached biomass was 150 – 340 g per tank while mass of biomass in the water column was 3290 – 5430 g per tank. Comparing the two treatment technologies, aerated biofilm reactors (removal = 64 – 77%, k = 0.2 – 0.3 day⁻¹, removal rate = 36 – 43 g-N/m²-day, 16 – 19 g-N/m³-day) had more removal and faster removal rates per square meter of land footprint compared to the algae raceway ponds (removal = 38 – 77%, k = 0.1 – 0.2 day⁻¹, removal rate = 4 – 5 g- N/m²-day, 13 – 17 g-N/m³-day), likely due to direct application of aerators in the reactors.","abstract_html":"Nitrogen removal technologies can help dairy industries meet their nutrient management needs. This thesis investigated two separate treatment technologies for total ammonia nitrogen (TAN) removal: algae raceway ponds and aerated biofilm reactors. Six 1000- liter algae raceway ponds and four 1000-liter tote tanks, each equipped with 10 sheets of nonwoven geotextile (i.e., thermally bonded or needle-punched) biofilm substrate, were used to treat the effluent from a flush dairy in central coastal California (TAN = 251 mg/L, cBOD5 = 204 mg/L). For the algae raceway ponds (TAN loading rate = 7 - 35 g/m³-day among 7-, 10- and 14-day hydraulic residence times (HRT)), first-order removal rate constants (k) were ~0.2 day⁻¹ in the summer and 0.1 - 0.2 day⁻¹ in the winter. Removal rate constants had no correlations (R² &lt; 0.1) with water temperature, weak to moderate (for 7-day ponds, R² = 0.55) correlations with insolation and weak to no correlations with biomass (i.e. volatile solids) concentration. During the winter, low insolation likely inhibited algal photosynthesis and biological TAN treatment. Ponds with 7-day HRT had distinct absence of nitrate and nitrite compared to 10- and 14-day ponds. Net productivities were ~20 g/m²-day in summer and 9 – 11 g/m²-day in winter; gross productivities were 120 – 160 g/m²-day in summer and 77 – 150 g/m²-day in winter. Productivities had no correlations (R² &lt; 0.1) with water temperature and weak to moderate correlations (for 14-day ponds, net productivity R² = 0.56, gross productivity R² = 0.83) with insolation. Analysis of organic compounds in pond effluent showed dissolved volatile solids (~2300 mg/L) were mostly non-biodegradable (~98% of soluble oxygen demand). Dissolved organic nitrogen concentrations in the pond effluent were ~35 mg/L. For the aerated biofilm reactors, tanks with needle-punched geotextiles had greater first- order TAN removal rate constants (0.69 day⁻¹) than tanks with thermally bonded geotextiles (0.23 day⁻¹) while operating in batch mode. Needle-punched geotextile reactor also accumulated sludge faster and had higher attached to water column biomass (i.e. volatile solids) ratios (~0.08 g VS/g VS) than thermally bonded geotextile reactor (~0.04 g VS/g VS). Among the four tanks, mass of attached biomass was 150 – 340 g per tank while mass of biomass in the water column was 3290 – 5430 g per tank. Comparing the two treatment technologies, aerated biofilm reactors (removal = 64 – 77%, k = 0.2 – 0.3 day⁻¹, removal rate = 36 – 43 g-N/m²-day, 16 – 19 g-N/m³-day) had more removal and faster removal rates per square meter of land footprint compared to the algae raceway ponds (removal = 38 – 77%, k = 0.1 – 0.2 day⁻¹, removal rate = 4 – 5 g- N/m²-day, 13 – 17 g-N/m³-day), likely due to direct application of aerators in the reactors.","abstract_has_math":false,"creators":["Son, Darin"],"institution":null,"degree_name":"MS in Civil and Environmental Engineering","degree_level":null,"degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Tryg Lundquist","Civil and Environmental Engineering","College of Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:11:02Z","subjects":["Dairy Wastewater","Raceway Pond","Aeration","Attached Media","Nitrification","Assimilation","Simultaneous Nitrification/Denitrification","Civil and Environmental Engineering","Environmental Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.15368/theses.2020.133"],"render_values":[{"text":"10.15368/theses.2020.133","href":"https://doi.org/10.15368/theses.2020.133","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/2222","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/2222","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-3721","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Tryg Lundquist","Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Son, Darin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-09-04T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-09-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Civil and Environmental Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dairy Wastewater","Raceway Pond","Aeration","Attached Media","Nitrification","Assimilation","Simultaneous Nitrification/Denitrification","Civil and Environmental Engineering","Environmental Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/2222","10.15368/theses.2020.133"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Nitrogen removal technologies can help dairy industries meet their nutrient management needs. This thesis investigated two separate treatment technologies for total ammonia nitrogen (TAN) removal: algae raceway ponds and aerated biofilm reactors. Six 1000- liter algae raceway ponds and four 1000-liter tote tanks, each equipped with 10 sheets of nonwoven geotextile (i.e., thermally bonded or needle-punched) biofilm substrate, were used to treat the effluent from a flush dairy in central coastal California (TAN = 251 mg/L, cBOD5 = 204 mg/L). For the algae raceway ponds (TAN loading rate = 7 - 35 g/m³-day among 7-, 10- and 14-day hydraulic residence times (HRT)), first-order removal rate constants (k) were ~0.2 day⁻¹ in the summer and 0.1 - 0.2 day⁻¹ in the winter. Removal rate constants had no correlations (R² < 0.1) with water temperature, weak to moderate (for 7-day ponds, R² = 0.55) correlations with insolation and weak to no correlations with biomass (i.e. volatile solids) concentration. During the winter, low insolation likely inhibited algal photosynthesis and biological TAN treatment. Ponds with 7-day HRT had distinct absence of nitrate and nitrite compared to 10- and 14-day ponds. Net productivities were ~20 g/m²-day in summer and 9 – 11 g/m²-day in winter; gross productivities were 120 – 160 g/m²-day in summer and 77 – 150 g/m²-day in winter. Productivities had no correlations (R² < 0.1) with water temperature and weak to moderate correlations (for 14-day ponds, net productivity R² = 0.56, gross productivity R² = 0.83) with insolation. Analysis of organic compounds in pond effluent showed dissolved volatile solids (~2300 mg/L) were mostly non-biodegradable (~98% of soluble oxygen demand). Dissolved organic nitrogen concentrations in the pond effluent were ~35 mg/L. For the aerated biofilm reactors, tanks with needle-punched geotextiles had greater first- order TAN removal rate constants (0.69 day⁻¹) than tanks with thermally bonded geotextiles (0.23 day⁻¹) while operating in batch mode. Needle-punched geotextile reactor also accumulated sludge faster and had higher attached to water column biomass (i.e. volatile solids) ratios (~0.08 g VS/g VS) than thermally bonded geotextile reactor (~0.04 g VS/g VS). Among the four tanks, mass of attached biomass was 150 – 340 g per tank while mass of biomass in the water column was 3290 – 5430 g per tank. Comparing the two treatment technologies, aerated biofilm reactors (removal = 64 – 77%, k = 0.2 – 0.3 day⁻¹, removal rate = 36 – 43 g-N/m²-day, 16 – 19 g-N/m³-day) had more removal and faster removal rates per square meter of land footprint compared to the algae raceway ponds (removal = 38 – 77%, k = 0.1 – 0.2 day⁻¹, removal rate = 4 – 5 g- N/m²-day, 13 – 17 g-N/m³-day), likely due to direct application of aerators in the reactors."]},{"key":"dc:title","label":"Title","values":["Dairy Manure Flushwater Treatment by Algae Raceway Ponds and Aerated Biofilm Reactors"]}]}],"canonical_facts":{"dc:contributor":["Tryg Lundquist","Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Son, Darin"],"dc:date.available":["2021-09-04T07:00:00Z"],"dc:date.created":["2020-09-01T07:00:00Z"],"dc:description.abstract":["Nitrogen removal technologies can help dairy industries meet their nutrient management needs. This thesis investigated two separate treatment technologies for total ammonia nitrogen (TAN) removal: algae raceway ponds and aerated biofilm reactors. Six 1000- liter algae raceway ponds and four 1000-liter tote tanks, each equipped with 10 sheets of nonwoven geotextile (i.e., thermally bonded or needle-punched) biofilm substrate, were used to treat the effluent from a flush dairy in central coastal California (TAN = 251 mg/L, cBOD5 = 204 mg/L). For the algae raceway ponds (TAN loading rate = 7 - 35 g/m³-day among 7-, 10- and 14-day hydraulic residence times (HRT)), first-order removal rate constants (k) were ~0.2 day⁻¹ in the summer and 0.1 - 0.2 day⁻¹ in the winter. Removal rate constants had no correlations (R² < 0.1) with water temperature, weak to moderate (for 7-day ponds, R² = 0.55) correlations with insolation and weak to no correlations with biomass (i.e. volatile solids) concentration. During the winter, low insolation likely inhibited algal photosynthesis and biological TAN treatment. Ponds with 7-day HRT had distinct absence of nitrate and nitrite compared to 10- and 14-day ponds. Net productivities were ~20 g/m²-day in summer and 9 – 11 g/m²-day in winter; gross productivities were 120 – 160 g/m²-day in summer and 77 – 150 g/m²-day in winter. Productivities had no correlations (R² < 0.1) with water temperature and weak to moderate correlations (for 14-day ponds, net productivity R² = 0.56, gross productivity R² = 0.83) with insolation. Analysis of organic compounds in pond effluent showed dissolved volatile solids (~2300 mg/L) were mostly non-biodegradable (~98% of soluble oxygen demand). Dissolved organic nitrogen concentrations in the pond effluent were ~35 mg/L. For the aerated biofilm reactors, tanks with needle-punched geotextiles had greater first- order TAN removal rate constants (0.69 day⁻¹) than tanks with thermally bonded geotextiles (0.23 day⁻¹) while operating in batch mode. Needle-punched geotextile reactor also accumulated sludge faster and had higher attached to water column biomass (i.e. volatile solids) ratios (~0.08 g VS/g VS) than thermally bonded geotextile reactor (~0.04 g VS/g VS). Among the four tanks, mass of attached biomass was 150 – 340 g per tank while mass of biomass in the water column was 3290 – 5430 g per tank. Comparing the two treatment technologies, aerated biofilm reactors (removal = 64 – 77%, k = 0.2 – 0.3 day⁻¹, removal rate = 36 – 43 g-N/m²-day, 16 – 19 g-N/m³-day) had more removal and faster removal rates per square meter of land footprint compared to the algae raceway ponds (removal = 38 – 77%, k = 0.1 – 0.2 day⁻¹, removal rate = 4 – 5 g- N/m²-day, 13 – 17 g-N/m³-day), likely due to direct application of aerators in the reactors."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/2222","10.15368/theses.2020.133"],"dc:subject":["Dairy Wastewater","Raceway Pond","Aeration","Attached Media","Nitrification","Assimilation","Simultaneous Nitrification/Denitrification","Civil and Environmental Engineering","Environmental Engineering"],"dc:title":["Dairy Manure Flushwater Treatment by Algae Raceway Ponds and Aerated Biofilm Reactors"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_name":["MS in Civil and Environmental Engineering"]},"updated_at":"2026-11-19T07:11:02Z"}