{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-3754"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-3754","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Finite Element Analysis of Total Knee Arthroplasty","abstract":"The total knee arthroplasty (TKA) has become one of the most successful procedures in all of medicine, with an average of over 966,000 operations performed a year. Since its introduction in 1968, the TKA’s surgical process and implant designs have continuously been improved to increase survivability. However, the need for a revision TKA – due to aseptic loosening – continues to be a problematic aspect of the procedure. Stress shielding induced by different design parameters of the implant has generated controversy in the determination of an ideal configuration. The purpose of this study is to investigate how implant design parameters – fixation technique, stem geometry, cement stiffness, and interface condition – affect the stress shielding within the tibia, and to find an optimal combination of designs that mitigates stress shielding. A CT scan of a tibia was used to simulate multiple configurations of TKAs for finite element analysis in ABAQUS. Stress shielding was assessed by taking the average minimum principal stress of different regions at interval cuts along the depth of the tibia. The results concluded a short, full-cement stem to be the ideal combination of stem length and fixation technique, high-stiffness cement to be ideal for hybrid cements, low-stiffness cement to be ideal for full cements, and a sliding friction interface to be ideal for all models.","abstract_html":"The total knee arthroplasty (TKA) has become one of the most successful procedures in all of medicine, with an average of over 966,000 operations performed a year. Since its introduction in 1968, the TKA’s surgical process and implant designs have continuously been improved to increase survivability. However, the need for a revision TKA – due to aseptic loosening – continues to be a problematic aspect of the procedure. Stress shielding induced by different design parameters of the implant has generated controversy in the determination of an ideal configuration. The purpose of this study is to investigate how implant design parameters – fixation technique, stem geometry, cement stiffness, and interface condition – affect the stress shielding within the tibia, and to find an optimal combination of designs that mitigates stress shielding. A CT scan of a tibia was used to simulate multiple configurations of TKAs for finite element analysis in ABAQUS. Stress shielding was assessed by taking the average minimum principal stress of different regions at interval cuts along the depth of the tibia. The results concluded a short, full-cement stem to be the ideal combination of stem length and fixation technique, high-stiffness cement to be ideal for hybrid cements, low-stiffness cement to be ideal for full cements, and a sliding friction interface to be ideal for all models.","abstract_has_math":false,"creators":["Yueh, Sean"],"institution":null,"degree_name":"MS in Mechanical Engineering","degree_level":null,"degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Mohammad Noori","Mechanical Engineering","College of Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:11:02Z","subjects":["Total Knee Arthroplasty","Stress Shielding","Implant","Biomedical Engineering and Bioengineering","Mechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.15368/theses.2020.154"],"render_values":[{"text":"10.15368/theses.2020.154","href":"https://doi.org/10.15368/theses.2020.154","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/2257","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/2257","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-3754","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mohammad Noori","Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Yueh, Sean"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2020-12-04T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-12-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Mechanical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Total Knee Arthroplasty","Stress Shielding","Implant","Biomedical Engineering and Bioengineering","Mechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/2257","10.15368/theses.2020.154"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The total knee arthroplasty (TKA) has become one of the most successful procedures in all of medicine, with an average of over 966,000 operations performed a year. Since its introduction in 1968, the TKA’s surgical process and implant designs have continuously been improved to increase survivability. However, the need for a revision TKA – due to aseptic loosening – continues to be a problematic aspect of the procedure. Stress shielding induced by different design parameters of the implant has generated controversy in the determination of an ideal configuration. The purpose of this study is to investigate how implant design parameters – fixation technique, stem geometry, cement stiffness, and interface condition – affect the stress shielding within the tibia, and to find an optimal combination of designs that mitigates stress shielding. A CT scan of a tibia was used to simulate multiple configurations of TKAs for finite element analysis in ABAQUS. Stress shielding was assessed by taking the average minimum principal stress of different regions at interval cuts along the depth of the tibia. The results concluded a short, full-cement stem to be the ideal combination of stem length and fixation technique, high-stiffness cement to be ideal for hybrid cements, low-stiffness cement to be ideal for full cements, and a sliding friction interface to be ideal for all models."]},{"key":"dc:title","label":"Title","values":["Finite Element Analysis of Total Knee Arthroplasty"]}]}],"canonical_facts":{"dc:contributor":["Mohammad Noori","Mechanical Engineering","College of Engineering"],"dc:creator":["Yueh, Sean"],"dc:date.available":["2020-12-04T08:00:00Z"],"dc:date.created":["2020-12-01T08:00:00Z"],"dc:description.abstract":["The total knee arthroplasty (TKA) has become one of the most successful procedures in all of medicine, with an average of over 966,000 operations performed a year. Since its introduction in 1968, the TKA’s surgical process and implant designs have continuously been improved to increase survivability. However, the need for a revision TKA – due to aseptic loosening – continues to be a problematic aspect of the procedure. Stress shielding induced by different design parameters of the implant has generated controversy in the determination of an ideal configuration. The purpose of this study is to investigate how implant design parameters – fixation technique, stem geometry, cement stiffness, and interface condition – affect the stress shielding within the tibia, and to find an optimal combination of designs that mitigates stress shielding. A CT scan of a tibia was used to simulate multiple configurations of TKAs for finite element analysis in ABAQUS. Stress shielding was assessed by taking the average minimum principal stress of different regions at interval cuts along the depth of the tibia. The results concluded a short, full-cement stem to be the ideal combination of stem length and fixation technique, high-stiffness cement to be ideal for hybrid cements, low-stiffness cement to be ideal for full cements, and a sliding friction interface to be ideal for all models."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/2257","10.15368/theses.2020.154"],"dc:subject":["Total Knee Arthroplasty","Stress Shielding","Implant","Biomedical Engineering and Bioengineering","Mechanical Engineering"],"dc:title":["Finite Element Analysis of Total Knee Arthroplasty"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_name":["MS in Mechanical Engineering"]},"updated_at":"2026-11-19T07:11:02Z"}