{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-4382"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-4382","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"USING NONINVASIVE CALIBRATED CUFF PLETHYSMOGRAPHY TO OBSERVE THE EFFECTS OF COLD-WATER IMMERSION ON ARTERIAL COMPLIANCE","abstract":"As the prevalence of cardiovascular diseases continues to exponentially grow in populations across the globe, the necessity of determining underlying factors, effective methods of diagnoses, and universally available preventive measures also grows. Early detection of endothelial dysfunction, a proven precursor of cardiovascular diseases, can be extremely impactful in encouraging preventative measures and early intervention before medical conditions become chronic. In recent years, ice plunging, a form of cryotherapy involving full body immersion in cold water, has gained popularity within circles of fitness and health practitioners, gaining the interest of people of all backgrounds. Certain parallels observed between the human physiological response to cold exposure and endothelial function encourage further study of the effects of ice plunging on cardiovascular health. Calibrated cuff plethysmography is a promising method of reflecting on endothelial function by measuring arterial compliance of select blood vessels. In this study, a calibrated cuff plethysmography device was built and tested for efficiency as it was used to measure compliance and cross-sectional area of the brachial artery of 14 participants 30 minutes before, immediately after, and 30 minutes after a 5-minute cold plunge in a temperature of 10°C - 15°C. Results found some significant differences between baseline measurements recorded immediately after the ice plunge and measurements recorded during reactive hyperemia conditions at normal body temperature but did not conclude that 5-minute cold-water immersion intervention had a significant impact on arterial compliance or area overall since this was a short term experiment with only acute intervention methods. The device used was concluded to effectively measure arterial compliance and area.","abstract_html":"As the prevalence of cardiovascular diseases continues to exponentially grow in populations across the globe, the necessity of determining underlying factors, effective methods of diagnoses, and universally available preventive measures also grows. Early detection of endothelial dysfunction, a proven precursor of cardiovascular diseases, can be extremely impactful in encouraging preventative measures and early intervention before medical conditions become chronic. In recent years, ice plunging, a form of cryotherapy involving full body immersion in cold water, has gained popularity within circles of fitness and health practitioners, gaining the interest of people of all backgrounds. Certain parallels observed between the human physiological response to cold exposure and endothelial function encourage further study of the effects of ice plunging on cardiovascular health. Calibrated cuff plethysmography is a promising method of reflecting on endothelial function by measuring arterial compliance of select blood vessels. In this study, a calibrated cuff plethysmography device was built and tested for efficiency as it was used to measure compliance and cross-sectional area of the brachial artery of 14 participants 30 minutes before, immediately after, and 30 minutes after a 5-minute cold plunge in a temperature of 10°C - 15°C. Results found some significant differences between baseline measurements recorded immediately after the ice plunge and measurements recorded during reactive hyperemia conditions at normal body temperature but did not conclude that 5-minute cold-water immersion intervention had a significant impact on arterial compliance or area overall since this was a short term experiment with only acute intervention methods. The device used was concluded to effectively measure arterial compliance and area.","abstract_has_math":false,"creators":["Grigorian, Rita M"],"institution":null,"degree_name":"MS in Biomedical Engineering","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Michael Whitt","Biomedical Engineering","College of Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:12:10Z","subjects":["Endothelial Dysfunction","Cold-Water Immersion","Angiogenesis","Thermogenesis","Calibrated Cuff Plethysmography","Cardiovascular Disease","Biological Phenomena, Cell Phenomena, and Immunity","Biomedical Devices and Instrumentation","Cardiology","Cardiovascular Diseases","Exercise Physiology","Homeopathy","Human and Clinical Nutrition","Medical Anatomy","Medical Pathology","Other Biomedical Engineering and Bioengineering","Other Nutrition","Pathological Conditions, Signs and Symptoms","Quality Improvement","Sports Medicine"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/2693","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/2693","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-4382","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Michael Whitt","Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Grigorian, Rita M"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-11-06T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-10-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Endothelial Dysfunction","Cold-Water Immersion","Angiogenesis","Thermogenesis","Calibrated Cuff Plethysmography","Cardiovascular Disease","Biological Phenomena, Cell Phenomena, and Immunity","Biomedical Devices and Instrumentation","Cardiology","Cardiovascular Diseases","Exercise Physiology","Homeopathy","Human and Clinical Nutrition","Medical Anatomy","Medical Pathology","Other Biomedical Engineering and Bioengineering","Other Nutrition","Pathological Conditions, Signs and Symptoms","Quality Improvement","Sports Medicine"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/2693"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["As the prevalence of cardiovascular diseases continues to exponentially grow in populations across the globe, the necessity of determining underlying factors, effective methods of diagnoses, and universally available preventive measures also grows. Early detection of endothelial dysfunction, a proven precursor of cardiovascular diseases, can be extremely impactful in encouraging preventative measures and early intervention before medical conditions become chronic. In recent years, ice plunging, a form of cryotherapy involving full body immersion in cold water, has gained popularity within circles of fitness and health practitioners, gaining the interest of people of all backgrounds. Certain parallels observed between the human physiological response to cold exposure and endothelial function encourage further study of the effects of ice plunging on cardiovascular health. Calibrated cuff plethysmography is a promising method of reflecting on endothelial function by measuring arterial compliance of select blood vessels. In this study, a calibrated cuff plethysmography device was built and tested for efficiency as it was used to measure compliance and cross-sectional area of the brachial artery of 14 participants 30 minutes before, immediately after, and 30 minutes after a 5-minute cold plunge in a temperature of 10°C - 15°C. Results found some significant differences between baseline measurements recorded immediately after the ice plunge and measurements recorded during reactive hyperemia conditions at normal body temperature but did not conclude that 5-minute cold-water immersion intervention had a significant impact on arterial compliance or area overall since this was a short term experiment with only acute intervention methods. The device used was concluded to effectively measure arterial compliance and area."]},{"key":"dc:title","label":"Title","values":["USING NONINVASIVE CALIBRATED CUFF PLETHYSMOGRAPHY TO OBSERVE THE EFFECTS OF COLD-WATER IMMERSION ON ARTERIAL COMPLIANCE"]}]}],"canonical_facts":{"dc:contributor":["Michael Whitt","Biomedical Engineering","College of Engineering"],"dc:creator":["Grigorian, Rita M"],"dc:date.available":["2023-11-06T08:00:00Z"],"dc:date.created":["2023-10-01T07:00:00Z"],"dc:description.abstract":["As the prevalence of cardiovascular diseases continues to exponentially grow in populations across the globe, the necessity of determining underlying factors, effective methods of diagnoses, and universally available preventive measures also grows. Early detection of endothelial dysfunction, a proven precursor of cardiovascular diseases, can be extremely impactful in encouraging preventative measures and early intervention before medical conditions become chronic. In recent years, ice plunging, a form of cryotherapy involving full body immersion in cold water, has gained popularity within circles of fitness and health practitioners, gaining the interest of people of all backgrounds. Certain parallels observed between the human physiological response to cold exposure and endothelial function encourage further study of the effects of ice plunging on cardiovascular health. Calibrated cuff plethysmography is a promising method of reflecting on endothelial function by measuring arterial compliance of select blood vessels. In this study, a calibrated cuff plethysmography device was built and tested for efficiency as it was used to measure compliance and cross-sectional area of the brachial artery of 14 participants 30 minutes before, immediately after, and 30 minutes after a 5-minute cold plunge in a temperature of 10°C - 15°C. Results found some significant differences between baseline measurements recorded immediately after the ice plunge and measurements recorded during reactive hyperemia conditions at normal body temperature but did not conclude that 5-minute cold-water immersion intervention had a significant impact on arterial compliance or area overall since this was a short term experiment with only acute intervention methods. The device used was concluded to effectively measure arterial compliance and area."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/2693"],"dc:subject":["Endothelial Dysfunction","Cold-Water Immersion","Angiogenesis","Thermogenesis","Calibrated Cuff Plethysmography","Cardiovascular Disease","Biological Phenomena, Cell Phenomena, and Immunity","Biomedical Devices and Instrumentation","Cardiology","Cardiovascular Diseases","Exercise Physiology","Homeopathy","Human and Clinical Nutrition","Medical Anatomy","Medical Pathology","Other Biomedical Engineering and Bioengineering","Other Nutrition","Pathological Conditions, Signs and Symptoms","Quality Improvement","Sports Medicine"],"dc:title":["USING NONINVASIVE CALIBRATED CUFF PLETHYSMOGRAPHY TO OBSERVE THE EFFECTS OF COLD-WATER IMMERSION ON ARTERIAL COMPLIANCE"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["MS in Biomedical Engineering"]},"updated_at":"2026-11-19T07:12:10Z"}