{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-4437"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-4437","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Development of a Cell Culture Incubator Capable of Providing a Hypoxic Environment","abstract":"In order to perform more robust and physiologically relevant research, the Microphysiological Systems laboratory required a method of culturing cells where the level of oxygen could be adjusted. To fulfill this need, I designed and manufactured a hypoxic cell culture incubator. I employed a Quality Function Deployment to understand the customer requirements and convert them into engineering specifications. Based on these specifications, I created various conceptual designs. I evaluated the conceptual designs as compared to existing products and decided to move forward with the control system separated from a small, standard chamber. I developed the circuitry schematics for the temperature control loop, incorporating three heating pads and a temperature sensor, and the gas concentration control loop, incorporating three solenoids and two gas concentration sensors for oxygen and carbon dioxide. I designed the chamber in SolidWorks and 3D printed it. Finally, I performed vigorous validation testing of the device’s ability to control the temperature, the concentration of carbon dioxide, and the concentration of oxygen. The incubator was able to maintain the temperature within 0.5 degrees Celsius of a setpoint, the concentration of carbon dioxide within 0.24% of a setpoint, and the concentration of oxygen within 0.05% of a setpoint. These results surpassed the determined requirements.","abstract_html":"In order to perform more robust and physiologically relevant research, the Microphysiological Systems laboratory required a method of culturing cells where the level of oxygen could be adjusted. To fulfill this need, I designed and manufactured a hypoxic cell culture incubator. I employed a Quality Function Deployment to understand the customer requirements and convert them into engineering specifications. Based on these specifications, I created various conceptual designs. I evaluated the conceptual designs as compared to existing products and decided to move forward with the control system separated from a small, standard chamber. I developed the circuitry schematics for the temperature control loop, incorporating three heating pads and a temperature sensor, and the gas concentration control loop, incorporating three solenoids and two gas concentration sensors for oxygen and carbon dioxide. I designed the chamber in SolidWorks and 3D printed it. Finally, I performed vigorous validation testing of the device’s ability to control the temperature, the concentration of carbon dioxide, and the concentration of oxygen. The incubator was able to maintain the temperature within 0.5 degrees Celsius of a setpoint, the concentration of carbon dioxide within 0.24% of a setpoint, and the concentration of oxygen within 0.05% of a setpoint. These results surpassed the determined requirements.","abstract_has_math":false,"creators":["Coe, Grant Austin"],"institution":null,"degree_name":"MS in Biomedical Engineering","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Christopher Heylman","Biomedical Engineering","College of Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:12:29Z","subjects":["Hypoxia","Angiogenesis","Cell Culture","Control Systems","Biomedical Devices and Instrumentation"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/2973","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/2973","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-4437","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Christopher Heylman","Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Coe, Grant Austin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-03-20T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-03-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hypoxia","Angiogenesis","Cell Culture","Control Systems","Biomedical Devices and Instrumentation"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/2973"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In order to perform more robust and physiologically relevant research, the Microphysiological Systems laboratory required a method of culturing cells where the level of oxygen could be adjusted. To fulfill this need, I designed and manufactured a hypoxic cell culture incubator. I employed a Quality Function Deployment to understand the customer requirements and convert them into engineering specifications. Based on these specifications, I created various conceptual designs. I evaluated the conceptual designs as compared to existing products and decided to move forward with the control system separated from a small, standard chamber. I developed the circuitry schematics for the temperature control loop, incorporating three heating pads and a temperature sensor, and the gas concentration control loop, incorporating three solenoids and two gas concentration sensors for oxygen and carbon dioxide. I designed the chamber in SolidWorks and 3D printed it. Finally, I performed vigorous validation testing of the device’s ability to control the temperature, the concentration of carbon dioxide, and the concentration of oxygen. The incubator was able to maintain the temperature within 0.5 degrees Celsius of a setpoint, the concentration of carbon dioxide within 0.24% of a setpoint, and the concentration of oxygen within 0.05% of a setpoint. These results surpassed the determined requirements."]},{"key":"dc:title","label":"Title","values":["Development of a Cell Culture Incubator Capable of Providing a Hypoxic Environment"]}]}],"canonical_facts":{"dc:contributor":["Christopher Heylman","Biomedical Engineering","College of Engineering"],"dc:creator":["Coe, Grant Austin"],"dc:date.available":["2024-03-20T07:00:00Z"],"dc:date.created":["2024-03-01T08:00:00Z"],"dc:description.abstract":["In order to perform more robust and physiologically relevant research, the Microphysiological Systems laboratory required a method of culturing cells where the level of oxygen could be adjusted. To fulfill this need, I designed and manufactured a hypoxic cell culture incubator. I employed a Quality Function Deployment to understand the customer requirements and convert them into engineering specifications. Based on these specifications, I created various conceptual designs. I evaluated the conceptual designs as compared to existing products and decided to move forward with the control system separated from a small, standard chamber. I developed the circuitry schematics for the temperature control loop, incorporating three heating pads and a temperature sensor, and the gas concentration control loop, incorporating three solenoids and two gas concentration sensors for oxygen and carbon dioxide. I designed the chamber in SolidWorks and 3D printed it. Finally, I performed vigorous validation testing of the device’s ability to control the temperature, the concentration of carbon dioxide, and the concentration of oxygen. The incubator was able to maintain the temperature within 0.5 degrees Celsius of a setpoint, the concentration of carbon dioxide within 0.24% of a setpoint, and the concentration of oxygen within 0.05% of a setpoint. These results surpassed the determined requirements."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/2973"],"dc:subject":["Hypoxia","Angiogenesis","Cell Culture","Control Systems","Biomedical Devices and Instrumentation"],"dc:title":["Development of a Cell Culture Incubator Capable of Providing a Hypoxic Environment"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["MS in Biomedical Engineering"]},"updated_at":"2026-11-19T07:12:29Z"}