{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-4567"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-4567","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Validation Of Mobile Devices In Arbitrary Locations Against Force Plate Standard For Balance Assessment","abstract":"With balance assessment being essential to the prediction of fall risk and detection and assessment of motor disorders, increasing clinical accessibility to objective balance metrics is essential. Work has been done validating center of mass (COM) acceleration metrics against well regarded force plate center of pressure (COP) position standards for mobile device data acquisition systems, but most research is restricted to devices being close to the COM or strapped in a harness configuration. Through the use of rigid body kinematics and the inverted pendulum model, this study develops novel methodology for calculating COM acceleration using mobile devices in arbitrary positions, as well as a novel approach to validation through direct comparison of COP position predictions to force plate measurements. Validation of this methodology included comparison of smartphone and force plate results for COM accelerations and COP positions. Results showed good analysis performance for both approaches during subject intentional swaying, but results were limited in cases of little motion where good balance was observed.","abstract_html":"With balance assessment being essential to the prediction of fall risk and detection and assessment of motor disorders, increasing clinical accessibility to objective balance metrics is essential. Work has been done validating center of mass (COM) acceleration metrics against well regarded force plate center of pressure (COP) position standards for mobile device data acquisition systems, but most research is restricted to devices being close to the COM or strapped in a harness configuration. Through the use of rigid body kinematics and the inverted pendulum model, this study develops novel methodology for calculating COM acceleration using mobile devices in arbitrary positions, as well as a novel approach to validation through direct comparison of COP position predictions to force plate measurements. Validation of this methodology included comparison of smartphone and force plate results for COM accelerations and COP positions. Results showed good analysis performance for both approaches during subject intentional swaying, but results were limited in cases of little motion where good balance was observed.","abstract_has_math":false,"creators":["Ellsworth, German J"],"institution":null,"degree_name":"MS in Mechanical Engineering","degree_level":null,"degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Eric Ocegueda","Mechanical Engineering","College of Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:12:23Z","subjects":["Balance","Biomechanics","Inverted Pendulum","Rigid Body Kinematics","Force Plate","Inertial Measurement Unit","Biomechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/2889","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/2889","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-4567","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Eric Ocegueda","Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Ellsworth, German J"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-09-03T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-09-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Mechanical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Balance","Biomechanics","Inverted Pendulum","Rigid Body Kinematics","Force Plate","Inertial Measurement Unit","Biomechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/2889"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["With balance assessment being essential to the prediction of fall risk and detection and assessment of motor disorders, increasing clinical accessibility to objective balance metrics is essential. Work has been done validating center of mass (COM) acceleration metrics against well regarded force plate center of pressure (COP) position standards for mobile device data acquisition systems, but most research is restricted to devices being close to the COM or strapped in a harness configuration. Through the use of rigid body kinematics and the inverted pendulum model, this study develops novel methodology for calculating COM acceleration using mobile devices in arbitrary positions, as well as a novel approach to validation through direct comparison of COP position predictions to force plate measurements. Validation of this methodology included comparison of smartphone and force plate results for COM accelerations and COP positions. Results showed good analysis performance for both approaches during subject intentional swaying, but results were limited in cases of little motion where good balance was observed."]},{"key":"dc:title","label":"Title","values":["Validation Of Mobile Devices In Arbitrary Locations Against Force Plate Standard For Balance Assessment"]}]}],"canonical_facts":{"dc:contributor":["Eric Ocegueda","Mechanical Engineering","College of Engineering"],"dc:creator":["Ellsworth, German J"],"dc:date.available":["2024-09-03T07:00:00Z"],"dc:date.created":["2024-09-01T07:00:00Z"],"dc:description.abstract":["With balance assessment being essential to the prediction of fall risk and detection and assessment of motor disorders, increasing clinical accessibility to objective balance metrics is essential. Work has been done validating center of mass (COM) acceleration metrics against well regarded force plate center of pressure (COP) position standards for mobile device data acquisition systems, but most research is restricted to devices being close to the COM or strapped in a harness configuration. Through the use of rigid body kinematics and the inverted pendulum model, this study develops novel methodology for calculating COM acceleration using mobile devices in arbitrary positions, as well as a novel approach to validation through direct comparison of COP position predictions to force plate measurements. Validation of this methodology included comparison of smartphone and force plate results for COM accelerations and COP positions. Results showed good analysis performance for both approaches during subject intentional swaying, but results were limited in cases of little motion where good balance was observed."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/2889"],"dc:subject":["Balance","Biomechanics","Inverted Pendulum","Rigid Body Kinematics","Force Plate","Inertial Measurement Unit","Biomechanical Engineering"],"dc:title":["Validation Of Mobile Devices In Arbitrary Locations Against Force Plate Standard For Balance Assessment"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_name":["MS in Mechanical Engineering"]},"updated_at":"2026-11-19T07:12:23Z"}