{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-4602"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-4602","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Development of a Pressure Sensing System Coupled with Deployable Machine Learning Models for Assessing Residual Limb Fit in Lower Limb Prosthetics","abstract":"Lower limb amputations pose significant challenges for patients, with over 150,000 cases annually in the U.S., leading to a high demand for effective prosthetics. However, only 43% of lower limb prosthetic users report satisfaction, primarily due to issues with socket fit, which is critical for comfort, stability, and preventing injury. This study presents a deployable sensing system for potentially real-time monitoring of prosthetic socket fit by using pressure sensors and convolutional neural networks (CNNs) to analyze the pressure distribution within the socket. A novel CNN architecture, utilizing both dilated and strided convolutions, is proposed to effectively capture spatial-temporal patterns in multivariate timeseries data, which is processed as an image. The system was designed for edge deployment on the Sony Spresense microcontroller, maintaining a small model size while achieving high accuracy. Results show that the CNN models, particularly those optimized with the stochastic gradient descent (SGD), demonstrated robustness and high transferability. This system provides a cost-effective, portable solution to improve prosthetic fit, enhancing patient care and preventing gait-related injuries.","abstract_html":"Lower limb amputations pose significant challenges for patients, with over 150,000 cases annually in the U.S., leading to a high demand for effective prosthetics. However, only 43% of lower limb prosthetic users report satisfaction, primarily due to issues with socket fit, which is critical for comfort, stability, and preventing injury. This study presents a deployable sensing system for potentially real-time monitoring of prosthetic socket fit by using pressure sensors and convolutional neural networks (CNNs) to analyze the pressure distribution within the socket. A novel CNN architecture, utilizing both dilated and strided convolutions, is proposed to effectively capture spatial-temporal patterns in multivariate timeseries data, which is processed as an image. The system was designed for edge deployment on the Sony Spresense microcontroller, maintaining a small model size while achieving high accuracy. Results show that the CNN models, particularly those optimized with the stochastic gradient descent (SGD), demonstrated robustness and high transferability. This system provides a cost-effective, portable solution to improve prosthetic fit, enhancing patient care and preventing gait-related injuries.","abstract_has_math":false,"creators":["Lewter, Maxwell D"],"institution":null,"degree_name":"MS in Biomedical Engineering","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Long Wang","Civil and Environmental Engineering","College of Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:12:29Z","subjects":["Edge Deployment","Prosthetic","Machine Learning","Pressure Sensing","Gait","Microcontroller","Biomedical Devices and Instrumentation"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/2952","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/2952","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-4602","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Long Wang","Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Lewter, Maxwell D"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-12-12T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-12-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Edge Deployment","Prosthetic","Machine Learning","Pressure Sensing","Gait","Microcontroller","Biomedical Devices and Instrumentation"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/2952"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Lower limb amputations pose significant challenges for patients, with over 150,000 cases annually in the U.S., leading to a high demand for effective prosthetics. However, only 43% of lower limb prosthetic users report satisfaction, primarily due to issues with socket fit, which is critical for comfort, stability, and preventing injury. This study presents a deployable sensing system for potentially real-time monitoring of prosthetic socket fit by using pressure sensors and convolutional neural networks (CNNs) to analyze the pressure distribution within the socket. A novel CNN architecture, utilizing both dilated and strided convolutions, is proposed to effectively capture spatial-temporal patterns in multivariate timeseries data, which is processed as an image. The system was designed for edge deployment on the Sony Spresense microcontroller, maintaining a small model size while achieving high accuracy. Results show that the CNN models, particularly those optimized with the stochastic gradient descent (SGD), demonstrated robustness and high transferability. This system provides a cost-effective, portable solution to improve prosthetic fit, enhancing patient care and preventing gait-related injuries."]},{"key":"dc:title","label":"Title","values":["Development of a Pressure Sensing System Coupled with Deployable Machine Learning Models for Assessing Residual Limb Fit in Lower Limb Prosthetics"]}]}],"canonical_facts":{"dc:contributor":["Long Wang","Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Lewter, Maxwell D"],"dc:date.available":["2025-12-12T08:00:00Z"],"dc:date.created":["2024-12-01T08:00:00Z"],"dc:description.abstract":["Lower limb amputations pose significant challenges for patients, with over 150,000 cases annually in the U.S., leading to a high demand for effective prosthetics. However, only 43% of lower limb prosthetic users report satisfaction, primarily due to issues with socket fit, which is critical for comfort, stability, and preventing injury. This study presents a deployable sensing system for potentially real-time monitoring of prosthetic socket fit by using pressure sensors and convolutional neural networks (CNNs) to analyze the pressure distribution within the socket. A novel CNN architecture, utilizing both dilated and strided convolutions, is proposed to effectively capture spatial-temporal patterns in multivariate timeseries data, which is processed as an image. The system was designed for edge deployment on the Sony Spresense microcontroller, maintaining a small model size while achieving high accuracy. Results show that the CNN models, particularly those optimized with the stochastic gradient descent (SGD), demonstrated robustness and high transferability. This system provides a cost-effective, portable solution to improve prosthetic fit, enhancing patient care and preventing gait-related injuries."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/2952"],"dc:subject":["Edge Deployment","Prosthetic","Machine Learning","Pressure Sensing","Gait","Microcontroller","Biomedical Devices and Instrumentation"],"dc:title":["Development of a Pressure Sensing System Coupled with Deployable Machine Learning Models for Assessing Residual Limb Fit in Lower Limb Prosthetics"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["MS in Biomedical Engineering"]},"updated_at":"2026-11-19T07:12:29Z"}