{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-4766"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-4766","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Acoustic and Hemodynamic Analysis of Phantoms: Roughness and Flow Dynamics","abstract":"The purpose of this study was to determine whether different vascular phantoms, with and without a surrogate arm, could serve as effective analogs to the human brachial artery for assessing endothelial dysfunction, an early indicator of cardiovascular disease, particularly atherosclerosis. Atherosclerosis is characterized by plaque buildup and endothelial damage, which precede more severe clinical events and are often detectable through changes in vascular function. A 40” water tower was used to simulate diastolic pressure, enabling water flow through each phantom. Strain gauge pressure transducers were placed at both ends of the phantoms to measure pressure drop, while a microphone captured the sound profile of the flow. The sound was expected to vary between phantoms due to differences in their luminal endothelial linings, which affect Reynolds number and, consequently, friction factor and pressure drop. To analyze the sound data, a Fast Fourier Transform (FFT) was applied to convert time domain signals into the frequency domain. A two factor ANOVA was then conducted to evaluate the effects of two variables: the presence of a surrogate arm and the type of vascular phantom. Results showed that both the type of phantom and the presence of the surrogate arm had statistically significant effects on the measured parameters. These findings suggest that this prototype system holds promise for non-invasive clinical evaluation of endothelial dysfunction and early-stage atherosclerosis, potentially enabling earlier diagnosis and treatment, when intervention is most effective, thereby improving patient outcomes and saving lives.","abstract_html":"The purpose of this study was to determine whether different vascular phantoms, with and without a surrogate arm, could serve as effective analogs to the human brachial artery for assessing endothelial dysfunction, an early indicator of cardiovascular disease, particularly atherosclerosis. Atherosclerosis is characterized by plaque buildup and endothelial damage, which precede more severe clinical events and are often detectable through changes in vascular function. A 40” water tower was used to simulate diastolic pressure, enabling water flow through each phantom. Strain gauge pressure transducers were placed at both ends of the phantoms to measure pressure drop, while a microphone captured the sound profile of the flow. The sound was expected to vary between phantoms due to differences in their luminal endothelial linings, which affect Reynolds number and, consequently, friction factor and pressure drop. To analyze the sound data, a Fast Fourier Transform (FFT) was applied to convert time domain signals into the frequency domain. A two factor ANOVA was then conducted to evaluate the effects of two variables: the presence of a surrogate arm and the type of vascular phantom. Results showed that both the type of phantom and the presence of the surrogate arm had statistically significant effects on the measured parameters. These findings suggest that this prototype system holds promise for non-invasive clinical evaluation of endothelial dysfunction and early-stage atherosclerosis, potentially enabling earlier diagnosis and treatment, when intervention is most effective, thereby improving patient outcomes and saving lives.","abstract_has_math":false,"creators":["Sundberg, Ethan Erik Olof"],"institution":null,"degree_name":"MS in Biomedical Engineering","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Michael Whitt","Biomedical Engineering","College of Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:12:36Z","subjects":["Endothelial Dysfunction","Atherosclerosis","BIOPAC","FFT","CVD","Vascular Phantom","Bioimaging and Biomedical Optics","Biomedical Devices and Instrumentation","Diagnosis","Other Analytical, Diagnostic and Therapeutic Techniques and Equipment","Other Biomedical Engineering and Bioengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/3067","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/3067","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-4766","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Michael Whitt","Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Sundberg, Ethan Erik Olof"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-06-13T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-06-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Endothelial Dysfunction","Atherosclerosis","BIOPAC","FFT","CVD","Vascular Phantom","Bioimaging and Biomedical Optics","Biomedical Devices and Instrumentation","Diagnosis","Other Analytical, Diagnostic and Therapeutic Techniques and Equipment","Other Biomedical Engineering and Bioengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/3067"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this study was to determine whether different vascular phantoms, with and without a surrogate arm, could serve as effective analogs to the human brachial artery for assessing endothelial dysfunction, an early indicator of cardiovascular disease, particularly atherosclerosis. Atherosclerosis is characterized by plaque buildup and endothelial damage, which precede more severe clinical events and are often detectable through changes in vascular function. A 40” water tower was used to simulate diastolic pressure, enabling water flow through each phantom. Strain gauge pressure transducers were placed at both ends of the phantoms to measure pressure drop, while a microphone captured the sound profile of the flow. The sound was expected to vary between phantoms due to differences in their luminal endothelial linings, which affect Reynolds number and, consequently, friction factor and pressure drop. To analyze the sound data, a Fast Fourier Transform (FFT) was applied to convert time domain signals into the frequency domain. A two factor ANOVA was then conducted to evaluate the effects of two variables: the presence of a surrogate arm and the type of vascular phantom. Results showed that both the type of phantom and the presence of the surrogate arm had statistically significant effects on the measured parameters. These findings suggest that this prototype system holds promise for non-invasive clinical evaluation of endothelial dysfunction and early-stage atherosclerosis, potentially enabling earlier diagnosis and treatment, when intervention is most effective, thereby improving patient outcomes and saving lives."]},{"key":"dc:title","label":"Title","values":["Acoustic and Hemodynamic Analysis of Phantoms: Roughness and Flow Dynamics"]}]}],"canonical_facts":{"dc:contributor":["Michael Whitt","Biomedical Engineering","College of Engineering"],"dc:creator":["Sundberg, Ethan Erik Olof"],"dc:date.available":["2025-06-13T07:00:00Z"],"dc:date.created":["2025-06-01T07:00:00Z"],"dc:description.abstract":["The purpose of this study was to determine whether different vascular phantoms, with and without a surrogate arm, could serve as effective analogs to the human brachial artery for assessing endothelial dysfunction, an early indicator of cardiovascular disease, particularly atherosclerosis. Atherosclerosis is characterized by plaque buildup and endothelial damage, which precede more severe clinical events and are often detectable through changes in vascular function. A 40” water tower was used to simulate diastolic pressure, enabling water flow through each phantom. Strain gauge pressure transducers were placed at both ends of the phantoms to measure pressure drop, while a microphone captured the sound profile of the flow. The sound was expected to vary between phantoms due to differences in their luminal endothelial linings, which affect Reynolds number and, consequently, friction factor and pressure drop. To analyze the sound data, a Fast Fourier Transform (FFT) was applied to convert time domain signals into the frequency domain. A two factor ANOVA was then conducted to evaluate the effects of two variables: the presence of a surrogate arm and the type of vascular phantom. Results showed that both the type of phantom and the presence of the surrogate arm had statistically significant effects on the measured parameters. These findings suggest that this prototype system holds promise for non-invasive clinical evaluation of endothelial dysfunction and early-stage atherosclerosis, potentially enabling earlier diagnosis and treatment, when intervention is most effective, thereby improving patient outcomes and saving lives."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/3067"],"dc:subject":["Endothelial Dysfunction","Atherosclerosis","BIOPAC","FFT","CVD","Vascular Phantom","Bioimaging and Biomedical Optics","Biomedical Devices and Instrumentation","Diagnosis","Other Analytical, Diagnostic and Therapeutic Techniques and Equipment","Other Biomedical Engineering and Bioengineering"],"dc:title":["Acoustic and Hemodynamic Analysis of Phantoms: Roughness and Flow Dynamics"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["MS in Biomedical Engineering"]},"updated_at":"2026-11-19T07:12:36Z"}