{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-4768"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-4768","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Quantifying Harmful Trunk Postures: Inertial Sensor Analysis of Trunk Angle to Support Low Back Pain Prevention","abstract":"Low back pain is a highly prevalent condition worldwide, impacting up to 80% of individuals at least once in their lifetime. A critical gap in current prevention strategies is the lack of tools to accurately measure trunk posture and movement in real-world environments. Accurate identification of biomechanical risk requires information about movement intensity, duration, and frequency, yet traditional assessment methods rely on self-reporting or visual observation, which are time-consuming and prone to error. To address this gap, a wearable monitoring method, consisting of two Inertial Measurement Units, was designed to quantify risk exposure to the spine by measuring angular position of the trunk over time. This method was validated against an optoelectronic motion capture system during controlled single and multi plane movement protocols. High agreement was observed between the wearable system and motion capture for sagittal plane angles, with greater variability in coronal and transverse planes during multi-plane movement trials. These findings support the feasibility of using wearable IMUs to monitor trunk posture in field settings, particularly for capturing flexion-related low back pain risk.","abstract_html":"Low back pain is a highly prevalent condition worldwide, impacting up to 80% of individuals at least once in their lifetime. A critical gap in current prevention strategies is the lack of tools to accurately measure trunk posture and movement in real-world environments. Accurate identification of biomechanical risk requires information about movement intensity, duration, and frequency, yet traditional assessment methods rely on self-reporting or visual observation, which are time-consuming and prone to error. To address this gap, a wearable monitoring method, consisting of two Inertial Measurement Units, was designed to quantify risk exposure to the spine by measuring angular position of the trunk over time. This method was validated against an optoelectronic motion capture system during controlled single and multi plane movement protocols. High agreement was observed between the wearable system and motion capture for sagittal plane angles, with greater variability in coronal and transverse planes during multi-plane movement trials. These findings support the feasibility of using wearable IMUs to monitor trunk posture in field settings, particularly for capturing flexion-related low back pain risk.","abstract_has_math":false,"creators":["Bates, Elsa E"],"institution":null,"degree_name":"MS in Biomedical Engineering","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Britta Berg- Johansen","Biomedical Engineering","College of Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:12:36Z","subjects":["Wearable Device","Inertial Measurement Unit","Low Back Pain","Biomedical Devices and Instrumentation"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/3102","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/3102","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-4768","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Britta Berg- Johansen","Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Bates, Elsa E"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-06-13T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-06-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Wearable Device","Inertial Measurement Unit","Low Back Pain","Biomedical Devices and Instrumentation"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/3102"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Low back pain is a highly prevalent condition worldwide, impacting up to 80% of individuals at least once in their lifetime. A critical gap in current prevention strategies is the lack of tools to accurately measure trunk posture and movement in real-world environments. Accurate identification of biomechanical risk requires information about movement intensity, duration, and frequency, yet traditional assessment methods rely on self-reporting or visual observation, which are time-consuming and prone to error. To address this gap, a wearable monitoring method, consisting of two Inertial Measurement Units, was designed to quantify risk exposure to the spine by measuring angular position of the trunk over time. This method was validated against an optoelectronic motion capture system during controlled single and multi plane movement protocols. High agreement was observed between the wearable system and motion capture for sagittal plane angles, with greater variability in coronal and transverse planes during multi-plane movement trials. These findings support the feasibility of using wearable IMUs to monitor trunk posture in field settings, particularly for capturing flexion-related low back pain risk."]},{"key":"dc:title","label":"Title","values":["Quantifying Harmful Trunk Postures: Inertial Sensor Analysis of Trunk Angle to Support Low Back Pain Prevention"]}]}],"canonical_facts":{"dc:contributor":["Britta Berg- Johansen","Biomedical Engineering","College of Engineering"],"dc:creator":["Bates, Elsa E"],"dc:date.available":["2025-06-13T07:00:00Z"],"dc:date.created":["2025-06-01T07:00:00Z"],"dc:description.abstract":["Low back pain is a highly prevalent condition worldwide, impacting up to 80% of individuals at least once in their lifetime. A critical gap in current prevention strategies is the lack of tools to accurately measure trunk posture and movement in real-world environments. Accurate identification of biomechanical risk requires information about movement intensity, duration, and frequency, yet traditional assessment methods rely on self-reporting or visual observation, which are time-consuming and prone to error. To address this gap, a wearable monitoring method, consisting of two Inertial Measurement Units, was designed to quantify risk exposure to the spine by measuring angular position of the trunk over time. This method was validated against an optoelectronic motion capture system during controlled single and multi plane movement protocols. High agreement was observed between the wearable system and motion capture for sagittal plane angles, with greater variability in coronal and transverse planes during multi-plane movement trials. These findings support the feasibility of using wearable IMUs to monitor trunk posture in field settings, particularly for capturing flexion-related low back pain risk."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/3102"],"dc:subject":["Wearable Device","Inertial Measurement Unit","Low Back Pain","Biomedical Devices and Instrumentation"],"dc:title":["Quantifying Harmful Trunk Postures: Inertial Sensor Analysis of Trunk Angle to Support Low Back Pain Prevention"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["MS in Biomedical Engineering"]},"updated_at":"2026-11-19T07:12:36Z"}