{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-4839"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-4839","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"A Novel Microfluidic Device for Preclinical Testing of Chemotherapeutics","abstract":"This work demonstrates the feasibility of a novel microfluidic tumor model that reproduces physiologically relevant nutrient gradients and endothelium–tumor interactions, validating its potential as a preclinical test platform. Finite element simulations of glutamine diffusion and fluid dynamics aligned with experimental tracer studies, and co-cultures supported directed endothelial migration toward tumor spheroids, confirming the device’s ability to mimic in vivo–like behavior. Current preclinical models often fail to capture the complexity of the tumor microenvironment (TME), limiting their predictive value for therapeutic testing. Nutrient availability and angiogenic signaling are critical drivers of tumor progression, yet they are poorly represented in traditional in vitro systems. To address this gap, a microfluidic device incorporating a colorectal cancer tumor compartment with a central endothelial lined tube was designed. Computational models of transport were developed and compared to experimental measurements, and the device’s biological relevance was assessed with tumor–endothelial co-cultures. The findings highlight the device’s promise of bridging the gap between conventional in vitro assays and in vivo studies, ultimately advancing the development of more reliable platforms for therapeutic evaluation.","abstract_html":"This work demonstrates the feasibility of a novel microfluidic tumor model that reproduces physiologically relevant nutrient gradients and endothelium–tumor interactions, validating its potential as a preclinical test platform. Finite element simulations of glutamine diffusion and fluid dynamics aligned with experimental tracer studies, and co-cultures supported directed endothelial migration toward tumor spheroids, confirming the device’s ability to mimic in vivo–like behavior. Current preclinical models often fail to capture the complexity of the tumor microenvironment (TME), limiting their predictive value for therapeutic testing. Nutrient availability and angiogenic signaling are critical drivers of tumor progression, yet they are poorly represented in traditional in vitro systems. To address this gap, a microfluidic device incorporating a colorectal cancer tumor compartment with a central endothelial lined tube was designed. Computational models of transport were developed and compared to experimental measurements, and the device’s biological relevance was assessed with tumor–endothelial co-cultures. The findings highlight the device’s promise of bridging the gap between conventional in vitro assays and in vivo studies, ultimately advancing the development of more reliable platforms for therapeutic evaluation.","abstract_has_math":false,"creators":["Ogan, Kaija Saleh"],"institution":null,"degree_name":"MS in Biomedical Engineering","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Christopher Heylman","Biomedical Engineering","College of Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:12:41Z","subjects":["Microfluidic device","colorectal cancer","computational fluid dynamics","tumor spheroids","angiogenesis","Molecular, Cellular, and Tissue Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/3185","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/3185","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-4839","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Christopher Heylman","Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Ogan, Kaija Saleh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-11-23T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-12-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microfluidic device","colorectal cancer","computational fluid dynamics","tumor spheroids","angiogenesis","Molecular, Cellular, and Tissue Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/3185"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work demonstrates the feasibility of a novel microfluidic tumor model that reproduces physiologically relevant nutrient gradients and endothelium–tumor interactions, validating its potential as a preclinical test platform. Finite element simulations of glutamine diffusion and fluid dynamics aligned with experimental tracer studies, and co-cultures supported directed endothelial migration toward tumor spheroids, confirming the device’s ability to mimic in vivo–like behavior. Current preclinical models often fail to capture the complexity of the tumor microenvironment (TME), limiting their predictive value for therapeutic testing. Nutrient availability and angiogenic signaling are critical drivers of tumor progression, yet they are poorly represented in traditional in vitro systems. To address this gap, a microfluidic device incorporating a colorectal cancer tumor compartment with a central endothelial lined tube was designed. Computational models of transport were developed and compared to experimental measurements, and the device’s biological relevance was assessed with tumor–endothelial co-cultures. The findings highlight the device’s promise of bridging the gap between conventional in vitro assays and in vivo studies, ultimately advancing the development of more reliable platforms for therapeutic evaluation."]},{"key":"dc:title","label":"Title","values":["A Novel Microfluidic Device for Preclinical Testing of Chemotherapeutics"]}]}],"canonical_facts":{"dc:contributor":["Christopher Heylman","Biomedical Engineering","College of Engineering"],"dc:creator":["Ogan, Kaija Saleh"],"dc:date.available":["2025-11-23T08:00:00Z"],"dc:date.created":["2025-12-01T08:00:00Z"],"dc:description.abstract":["This work demonstrates the feasibility of a novel microfluidic tumor model that reproduces physiologically relevant nutrient gradients and endothelium–tumor interactions, validating its potential as a preclinical test platform. Finite element simulations of glutamine diffusion and fluid dynamics aligned with experimental tracer studies, and co-cultures supported directed endothelial migration toward tumor spheroids, confirming the device’s ability to mimic in vivo–like behavior. Current preclinical models often fail to capture the complexity of the tumor microenvironment (TME), limiting their predictive value for therapeutic testing. Nutrient availability and angiogenic signaling are critical drivers of tumor progression, yet they are poorly represented in traditional in vitro systems. To address this gap, a microfluidic device incorporating a colorectal cancer tumor compartment with a central endothelial lined tube was designed. Computational models of transport were developed and compared to experimental measurements, and the device’s biological relevance was assessed with tumor–endothelial co-cultures. The findings highlight the device’s promise of bridging the gap between conventional in vitro assays and in vivo studies, ultimately advancing the development of more reliable platforms for therapeutic evaluation."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/3185"],"dc:subject":["Microfluidic device","colorectal cancer","computational fluid dynamics","tumor spheroids","angiogenesis","Molecular, Cellular, and Tissue Engineering"],"dc:title":["A Novel Microfluidic Device for Preclinical Testing of Chemotherapeutics"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["MS in Biomedical Engineering"]},"updated_at":"2026-11-19T07:12:41Z"}