{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-4846"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-4846","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Time-Domain Symmetrical Components for Detection and Analysis of Unbalanced Faults in Three-Phase Systems","abstract":"Unbalanced faults in three-phase power systems degrade performance, increase losses, and threaten equipment reliability. Traditional frequency-domain approaches using phasor analysis and symmetrical components offer valuable steady-state insights but respond too slowly for transient or rapidly changing conditions. This thesis investigates time-domain symmetrical components (ISCs) as a faster, physically interpretable method for detecting and analyzing unbalanced faults directly from instantaneous voltages and currents. Two ISC computation techniques were developed and compared: a polar-form method, applying one-third and two-thirds cycle time delays, and a rectangular-form method, which achieves equivalent phase shifts using only a quarter-cycle delay. Simulations in Microsoft Excel verified both methods, with the rectangular approach demonstrating superior accuracy and reduced latency. Experimental validation was performed using a mechanically coupled three-phase synchronous motor-generator system under controlled fault and imbalance scenarios. Results confirmed that time-domain decomposition reliably identifies fault types and sequence behavior consistent with theoretical expectations. These findings indicate that instantaneous symmetrical components can enable sub-cycle fault detection, supporting faster, more reliable protective relaying for modern, dynamically evolving power systems.","abstract_html":"Unbalanced faults in three-phase power systems degrade performance, increase losses, and threaten equipment reliability. Traditional frequency-domain approaches using phasor analysis and symmetrical components offer valuable steady-state insights but respond too slowly for transient or rapidly changing conditions. This thesis investigates time-domain symmetrical components (ISCs) as a faster, physically interpretable method for detecting and analyzing unbalanced faults directly from instantaneous voltages and currents. Two ISC computation techniques were developed and compared: a polar-form method, applying one-third and two-thirds cycle time delays, and a rectangular-form method, which achieves equivalent phase shifts using only a quarter-cycle delay. Simulations in Microsoft Excel verified both methods, with the rectangular approach demonstrating superior accuracy and reduced latency. Experimental validation was performed using a mechanically coupled three-phase synchronous motor-generator system under controlled fault and imbalance scenarios. Results confirmed that time-domain decomposition reliably identifies fault types and sequence behavior consistent with theoretical expectations. These findings indicate that instantaneous symmetrical components can enable sub-cycle fault detection, supporting faster, more reliable protective relaying for modern, dynamically evolving power systems.","abstract_has_math":false,"creators":["Pospichal, Ryan"],"institution":null,"degree_name":"MS in Electrical Engineering","degree_level":null,"degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Majid Poshtan","Electrical Engineering","College of Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:12:41Z","subjects":["Three-phase systems","symmetrical components","time-domain analysis","asymmetric faults","protective relaying","Power and Energy"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/3202","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/3202","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-4846","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Majid Poshtan","Electrical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Pospichal, Ryan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-12-02T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-12-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Electrical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Three-phase systems","symmetrical components","time-domain analysis","asymmetric faults","protective relaying","Power and Energy"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/3202"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Unbalanced faults in three-phase power systems degrade performance, increase losses, and threaten equipment reliability. Traditional frequency-domain approaches using phasor analysis and symmetrical components offer valuable steady-state insights but respond too slowly for transient or rapidly changing conditions. This thesis investigates time-domain symmetrical components (ISCs) as a faster, physically interpretable method for detecting and analyzing unbalanced faults directly from instantaneous voltages and currents. Two ISC computation techniques were developed and compared: a polar-form method, applying one-third and two-thirds cycle time delays, and a rectangular-form method, which achieves equivalent phase shifts using only a quarter-cycle delay. Simulations in Microsoft Excel verified both methods, with the rectangular approach demonstrating superior accuracy and reduced latency. Experimental validation was performed using a mechanically coupled three-phase synchronous motor-generator system under controlled fault and imbalance scenarios. Results confirmed that time-domain decomposition reliably identifies fault types and sequence behavior consistent with theoretical expectations. These findings indicate that instantaneous symmetrical components can enable sub-cycle fault detection, supporting faster, more reliable protective relaying for modern, dynamically evolving power systems."]},{"key":"dc:title","label":"Title","values":["Time-Domain Symmetrical Components for Detection and Analysis of Unbalanced Faults in Three-Phase Systems"]}]}],"canonical_facts":{"dc:contributor":["Majid Poshtan","Electrical Engineering","College of Engineering"],"dc:creator":["Pospichal, Ryan"],"dc:date.available":["2025-12-02T08:00:00Z"],"dc:date.created":["2025-12-01T08:00:00Z"],"dc:description.abstract":["Unbalanced faults in three-phase power systems degrade performance, increase losses, and threaten equipment reliability. Traditional frequency-domain approaches using phasor analysis and symmetrical components offer valuable steady-state insights but respond too slowly for transient or rapidly changing conditions. This thesis investigates time-domain symmetrical components (ISCs) as a faster, physically interpretable method for detecting and analyzing unbalanced faults directly from instantaneous voltages and currents. Two ISC computation techniques were developed and compared: a polar-form method, applying one-third and two-thirds cycle time delays, and a rectangular-form method, which achieves equivalent phase shifts using only a quarter-cycle delay. Simulations in Microsoft Excel verified both methods, with the rectangular approach demonstrating superior accuracy and reduced latency. Experimental validation was performed using a mechanically coupled three-phase synchronous motor-generator system under controlled fault and imbalance scenarios. Results confirmed that time-domain decomposition reliably identifies fault types and sequence behavior consistent with theoretical expectations. These findings indicate that instantaneous symmetrical components can enable sub-cycle fault detection, supporting faster, more reliable protective relaying for modern, dynamically evolving power systems."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/3202"],"dc:subject":["Three-phase systems","symmetrical components","time-domain analysis","asymmetric faults","protective relaying","Power and Energy"],"dc:title":["Time-Domain Symmetrical Components for Detection and Analysis of Unbalanced Faults in Three-Phase Systems"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_name":["MS in Electrical Engineering"]},"updated_at":"2026-11-19T07:12:41Z"}