{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-5051"},"canonical_url":"https://search.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-5051","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Electrically Evoked EMG Decomposition using the Perturbative Generalized Series Expansion","abstract":"Electrically evoked electromyography records the muscle's response to nerve stimulation and has been used for clinical assessment of neuromuscular function, as well as treatments such as functional electrical stimulation or stroke rehabilitation. In every muscular contraction, an electrical signal is generated. These signals come from the summation of simultaneously recruited motor units, enabling decomposition techniques to reveal information about motor unit recruitment. By improving the ability to decompose and analyze these signals, clinical treatments involving neuromuscular electrical stimulation can be optimized and better understood. Much of the research on EMG analysis focuses on voluntary EMG, leaving a gap in the number of validated techniques for decomposing evoked EMG. In this thesis, Szlavik’s perturbation-based decomposition has been extended to synthetically modeled evoked EMGs and evaluated against the generalized Fourier series. These models were constructed using Associated Hermite basis functions to represent motor unit action potentials, which were summed to form a compound M-Wave and an M-Wave train. The following models were decomposed: a single M-Wave, a 50 Hz M-Wave train, and each of their noisy counterparts, evaluated at varying signal-to-noise ratios (SNR). Szlavik's algorithm successfully decomposed both noiseless models and maintained high accuracy estimates at SNRs of 15 and 20 dB. Additionally, the perturbation-based method outperformed the generalized Fourier series in decomposing all simulations.","abstract_html":"Electrically evoked electromyography records the muscle&#x27;s response to nerve stimulation and has been used for clinical assessment of neuromuscular function, as well as treatments such as functional electrical stimulation or stroke rehabilitation. In every muscular contraction, an electrical signal is generated. These signals come from the summation of simultaneously recruited motor units, enabling decomposition techniques to reveal information about motor unit recruitment. By improving the ability to decompose and analyze these signals, clinical treatments involving neuromuscular electrical stimulation can be optimized and better understood. Much of the research on EMG analysis focuses on voluntary EMG, leaving a gap in the number of validated techniques for decomposing evoked EMG. In this thesis, Szlavik’s perturbation-based decomposition has been extended to synthetically modeled evoked EMGs and evaluated against the generalized Fourier series. These models were constructed using Associated Hermite basis functions to represent motor unit action potentials, which were summed to form a compound M-Wave and an M-Wave train. The following models were decomposed: a single M-Wave, a 50 Hz M-Wave train, and each of their noisy counterparts, evaluated at varying signal-to-noise ratios (SNR). Szlavik&#x27;s algorithm successfully decomposed both noiseless models and maintained high accuracy estimates at SNRs of 15 and 20 dB. Additionally, the perturbation-based method outperformed the generalized Fourier series in decomposing all simulations.","abstract_has_math":false,"creators":["Walker, William R"],"institution":null,"degree_name":"MS in Biomedical Engineering","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Robert Szlavik","Biomedical Engineering","College of Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:12:58Z","subjects":["EMG signal decomposition","neuromuscular electrical stimulation","motor unit","perturbation based decomposition","Bioelectrical and Neuroengineering","Other Biomedical Engineering and Bioengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/3401","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.calpoly.edu/theses/3401","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.calpoly.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.calpoly.edu%3Atheses-5051","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Robert Szlavik","Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Walker, William R"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2026-06-12T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-06-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["EMG signal decomposition","neuromuscular electrical stimulation","motor unit","perturbation based decomposition","Bioelectrical and Neuroengineering","Other Biomedical Engineering and Bioengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/3401"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Electrically evoked electromyography records the muscle's response to nerve stimulation and has been used for clinical assessment of neuromuscular function, as well as treatments such as functional electrical stimulation or stroke rehabilitation. In every muscular contraction, an electrical signal is generated. These signals come from the summation of simultaneously recruited motor units, enabling decomposition techniques to reveal information about motor unit recruitment. By improving the ability to decompose and analyze these signals, clinical treatments involving neuromuscular electrical stimulation can be optimized and better understood. Much of the research on EMG analysis focuses on voluntary EMG, leaving a gap in the number of validated techniques for decomposing evoked EMG. In this thesis, Szlavik’s perturbation-based decomposition has been extended to synthetically modeled evoked EMGs and evaluated against the generalized Fourier series. These models were constructed using Associated Hermite basis functions to represent motor unit action potentials, which were summed to form a compound M-Wave and an M-Wave train. The following models were decomposed: a single M-Wave, a 50 Hz M-Wave train, and each of their noisy counterparts, evaluated at varying signal-to-noise ratios (SNR). Szlavik's algorithm successfully decomposed both noiseless models and maintained high accuracy estimates at SNRs of 15 and 20 dB. Additionally, the perturbation-based method outperformed the generalized Fourier series in decomposing all simulations."]},{"key":"dc:title","label":"Title","values":["Electrically Evoked EMG Decomposition using the Perturbative Generalized Series Expansion"]}]}],"canonical_facts":{"dc:contributor":["Robert Szlavik","Biomedical Engineering","College of Engineering"],"dc:creator":["Walker, William R"],"dc:date.available":["2026-06-12T07:00:00Z"],"dc:date.created":["2026-06-01T07:00:00Z"],"dc:description.abstract":["Electrically evoked electromyography records the muscle's response to nerve stimulation and has been used for clinical assessment of neuromuscular function, as well as treatments such as functional electrical stimulation or stroke rehabilitation. In every muscular contraction, an electrical signal is generated. These signals come from the summation of simultaneously recruited motor units, enabling decomposition techniques to reveal information about motor unit recruitment. By improving the ability to decompose and analyze these signals, clinical treatments involving neuromuscular electrical stimulation can be optimized and better understood. Much of the research on EMG analysis focuses on voluntary EMG, leaving a gap in the number of validated techniques for decomposing evoked EMG. In this thesis, Szlavik’s perturbation-based decomposition has been extended to synthetically modeled evoked EMGs and evaluated against the generalized Fourier series. These models were constructed using Associated Hermite basis functions to represent motor unit action potentials, which were summed to form a compound M-Wave and an M-Wave train. The following models were decomposed: a single M-Wave, a 50 Hz M-Wave train, and each of their noisy counterparts, evaluated at varying signal-to-noise ratios (SNR). Szlavik's algorithm successfully decomposed both noiseless models and maintained high accuracy estimates at SNRs of 15 and 20 dB. Additionally, the perturbation-based method outperformed the generalized Fourier series in decomposing all simulations."],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/3401"],"dc:subject":["EMG signal decomposition","neuromuscular electrical stimulation","motor unit","perturbation based decomposition","Bioelectrical and Neuroengineering","Other Biomedical Engineering and Bioengineering"],"dc:title":["Electrically Evoked EMG Decomposition using the Perturbative Generalized Series Expansion"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["MS in Biomedical Engineering"]},"updated_at":"2026-11-19T07:12:58Z"}