{"id":{"repo_id":"cape-town","oai_identifier":"oai:open.uct.ac.za:11427/11622"},"canonical_url":"https://search.ndltd.org/etd/cape-town/oai:open.uct.ac.za:11427/11622","repository":{"repo_id":"cape-town","name":"University of Cape Town","base_url":"https://open.uct.ac.za/oai/request"},"display":{"title":"Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation","abstract":"The high occurrence of vascular disease in the 20th century has been the driving force for researchers to produce a successful small diameter synthetic graft. Large diameter synthetic grafts remain patent for extended periods due to high flow rate, while smaller diameter grafts occlude more readily. Mechanical property mismatch between graft and host artery has been cited as one of the major factors that contribute to graft occlusion. It has thus been important to develop a readily available graft that is accepted by the body and does not cause flow abnormalities and stress-concentrations at graft-artery junctions. The object of this project was to ascertain the effect of an adventitial reinforcement on elastic compliance of synthetic porous polyurethane grafts.","abstract_html":"The high occurrence of vascular disease in the 20th century has been the driving force for researchers to produce a successful small diameter synthetic graft. Large diameter synthetic grafts remain patent for extended periods due to high flow rate, while smaller diameter grafts occlude more readily. Mechanical property mismatch between graft and host artery has been cited as one of the major factors that contribute to graft occlusion. It has thus been important to develop a readily available graft that is accepted by the body and does not cause flow abnormalities and stress-concentrations at graft-artery junctions. The object of this project was to ascertain the effect of an adventitial reinforcement on elastic compliance of synthetic porous polyurethane grafts.","abstract_has_math":false,"creators":["Millam, Ross David Alexander"],"institution":"Department of Medicine","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Zilla, Peter","Bezuidenhout, Deon"],"committee_chairs":[],"committee_members":[],"year":2001,"date_issued":"2001","date_published":"2001","updated_at":"2026-11-21T20:44:06Z","subjects":["Medicine"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.apacitation","label":"Dc Identifier Apacitation","values":["Millam, R. D. A. (2001). <i>Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation</i>. (Thesis). University of Cape Town ,Faculty of Health Sciences ,Department of Medicine. Retrieved from http://hdl.handle.net/11427/11622"],"render_values":[{"text":"Millam, R. D. A. (2001). <i>Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation</i>. (Thesis). University of Cape Town ,Faculty of Health Sciences ,Department of Medicine. Retrieved from http://hdl.handle.net/11427/11622","href":null,"code":true}]},{"key":"dc:identifier.chicagocitation","label":"Dc Identifier Chicagocitation","values":["Millam, Ross David Alexander. <i>\"Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation.\"</i> Thesis., University of Cape Town ,Faculty of Health Sciences ,Department of Medicine, 2001. http://hdl.handle.net/11427/11622"],"render_values":[{"text":"Millam, Ross David Alexander. <i>\"Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation.\"</i> Thesis., University of Cape Town ,Faculty of Health Sciences ,Department of Medicine, 2001. http://hdl.handle.net/11427/11622","href":null,"code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Millam, R. 2001. Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation. University of Cape Town."],"render_values":[{"text":"Millam, R. 2001. Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation. University of Cape Town.","href":null,"code":true}]},{"key":"dc:identifier.ris","label":"Dc Identifier Ris","values":["TY - Thesis / Dissertation AU - Millam, Ross David Alexander AB - The high occurrence of vascular disease in the 20th century has been the driving force for researchers to produce a successful small diameter synthetic graft. Large diameter synthetic grafts remain patent for extended periods due to high flow rate, while smaller diameter grafts occlude more readily. Mechanical property mismatch between graft and host artery has been cited as one of the major factors that contribute to graft occlusion. It has thus been important to develop a readily available graft that is accepted by the body and does not cause flow abnormalities and stress-concentrations at graft-artery junctions. The object of this project was to ascertain the effect of an adventitial reinforcement on elastic compliance of synthetic porous polyurethane grafts. DA - 2001 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2001 T1 - Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation TI - Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation UR - http://hdl.handle.net/11427/11622 ER -"],"render_values":[{"text":"TY - Thesis / Dissertation AU - Millam, Ross David Alexander AB - The high occurrence of vascular disease in the 20th century has been the driving force for researchers to produce a successful small diameter synthetic graft. Large diameter synthetic grafts remain patent for extended periods due to high flow rate, while smaller diameter grafts occlude more readily. Mechanical property mismatch between graft and host artery has been cited as one of the major factors that contribute to graft occlusion. It has thus been important to develop a readily available graft that is accepted by the body and does not cause flow abnormalities and stress-concentrations at graft-artery junctions. The object of this project was to ascertain the effect of an adventitial reinforcement on elastic compliance of synthetic porous polyurethane grafts. DA - 2001 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2001 T1 - Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation TI - Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation UR - http://hdl.handle.net/11427/11622 ER -","href":null,"code":true}]},{"key":"dc:identifier.vancouvercitation","label":"Dc Identifier Vancouvercitation","values":["Millam RDA. Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation. [Thesis]. University of Cape Town ,Faculty of Health Sciences ,Department of Medicine, 2001 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/11622"],"render_values":[{"text":"Millam RDA. Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation. [Thesis]. University of Cape Town ,Faculty of Health Sciences ,Department of Medicine, 2001 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/11622","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11427/11622","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11427/11622","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acape-town%3Aoai%3Aopen.uct.ac.za%3A11427%2F11622","prefix":"oai_dc"},"source_record":{"url":"https://open.uct.ac.za/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.uct.ac.za%3A11427%2F11622","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zilla, Peter","Bezuidenhout, Deon"]},{"key":"dc:creator","label":"Author","values":["Millam, Ross David Alexander"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-01-06T18:55:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-01-06T18:55:05Z"]},{"key":"dc:date.issued","label":"Date","values":["2001"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Medicine"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Faculty of Health Sciences"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Cape Town"]},{"key":"dc:type","label":"Dc Type","values":["Master Thesis"]},{"key":"dc:type.publication","label":"Dc Type Publication","values":["Research"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Masters"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["MSc"]},{"key":"dc:type.resource","label":"Dc Type Resource","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.other","label":"Dc Subject Other","values":["Medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.apacitation","label":"Dc Identifier Apacitation","values":["Millam, R. D. A. (2001). <i>Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation</i>. (Thesis). University of Cape Town ,Faculty of Health Sciences ,Department of Medicine. Retrieved from http://hdl.handle.net/11427/11622"]},{"key":"dc:identifier.chicagocitation","label":"Dc Identifier Chicagocitation","values":["Millam, Ross David Alexander. <i>\"Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation.\"</i> Thesis., University of Cape Town ,Faculty of Health Sciences ,Department of Medicine, 2001. http://hdl.handle.net/11427/11622"]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Millam, R. 2001. Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation. University of Cape Town."]},{"key":"dc:identifier.ris","label":"Dc Identifier Ris","values":["TY - Thesis / Dissertation AU - Millam, Ross David Alexander AB - The high occurrence of vascular disease in the 20th century has been the driving force for researchers to produce a successful small diameter synthetic graft. Large diameter synthetic grafts remain patent for extended periods due to high flow rate, while smaller diameter grafts occlude more readily. Mechanical property mismatch between graft and host artery has been cited as one of the major factors that contribute to graft occlusion. It has thus been important to develop a readily available graft that is accepted by the body and does not cause flow abnormalities and stress-concentrations at graft-artery junctions. The object of this project was to ascertain the effect of an adventitial reinforcement on elastic compliance of synthetic porous polyurethane grafts. DA - 2001 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2001 T1 - Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation TI - Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation UR - http://hdl.handle.net/11427/11622 ER -"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11427/11622"]},{"key":"dc:identifier.vancouvercitation","label":"Dc Identifier Vancouvercitation","values":["Millam RDA. Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation. [Thesis]. University of Cape Town ,Faculty of Health Sciences ,Department of Medicine, 2001 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/11622"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Includes bibliographical references."]},{"key":"dc:description.abstract","label":"Abstract","values":["The high occurrence of vascular disease in the 20th century has been the driving force for researchers to produce a successful small diameter synthetic graft. Large diameter synthetic grafts remain patent for extended periods due to high flow rate, while smaller diameter grafts occlude more readily. Mechanical property mismatch between graft and host artery has been cited as one of the major factors that contribute to graft occlusion. It has thus been important to develop a readily available graft that is accepted by the body and does not cause flow abnormalities and stress-concentrations at graft-artery junctions. The object of this project was to ascertain the effect of an adventitial reinforcement on elastic compliance of synthetic porous polyurethane grafts."]},{"key":"dc:format.filetype","label":"Dc Format Filetype","values":["Text","Image"]},{"key":"dc:title","label":"Title","values":["Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zilla, Peter","Bezuidenhout, Deon"],"dc:creator":["Millam, Ross David Alexander"],"dc:date.accessioned":["2015-01-06T18:55:05Z"],"dc:date.available":["2015-01-06T18:55:05Z"],"dc:date.issued":["2001"],"dc:description":["Includes bibliographical references."],"dc:description.abstract":["The high occurrence of vascular disease in the 20th century has been the driving force for researchers to produce a successful small diameter synthetic graft. Large diameter synthetic grafts remain patent for extended periods due to high flow rate, while smaller diameter grafts occlude more readily. Mechanical property mismatch between graft and host artery has been cited as one of the major factors that contribute to graft occlusion. It has thus been important to develop a readily available graft that is accepted by the body and does not cause flow abnormalities and stress-concentrations at graft-artery junctions. The object of this project was to ascertain the effect of an adventitial reinforcement on elastic compliance of synthetic porous polyurethane grafts."],"dc:format.filetype":["Text","Image"],"dc:identifier.apacitation":["Millam, R. D. A. (2001). <i>Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation</i>. (Thesis). University of Cape Town ,Faculty of Health Sciences ,Department of Medicine. Retrieved from http://hdl.handle.net/11427/11622"],"dc:identifier.chicagocitation":["Millam, Ross David Alexander. <i>\"Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation.\"</i> Thesis., University of Cape Town ,Faculty of Health Sciences ,Department of Medicine, 2001. http://hdl.handle.net/11427/11622"],"dc:identifier.citation":["Millam, R. 2001. Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation. University of Cape Town."],"dc:identifier.ris":["TY - Thesis / Dissertation AU - Millam, Ross David Alexander AB - The high occurrence of vascular disease in the 20th century has been the driving force for researchers to produce a successful small diameter synthetic graft. Large diameter synthetic grafts remain patent for extended periods due to high flow rate, while smaller diameter grafts occlude more readily. Mechanical property mismatch between graft and host artery has been cited as one of the major factors that contribute to graft occlusion. It has thus been important to develop a readily available graft that is accepted by the body and does not cause flow abnormalities and stress-concentrations at graft-artery junctions. The object of this project was to ascertain the effect of an adventitial reinforcement on elastic compliance of synthetic porous polyurethane grafts. DA - 2001 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2001 T1 - Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation TI - Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation UR - http://hdl.handle.net/11427/11622 ER -"],"dc:identifier.uri":["http://hdl.handle.net/11427/11622"],"dc:identifier.vancouvercitation":["Millam RDA. Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation. [Thesis]. University of Cape Town ,Faculty of Health Sciences ,Department of Medicine, 2001 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/11622"],"dc:language.iso":["eng"],"dc:publisher.department":["Department of Medicine"],"dc:publisher.faculty":["Faculty of Health Sciences"],"dc:publisher.institution":["University of Cape Town"],"dc:subject.other":["Medicine"],"dc:title":["Design of an adventitial type reinforcement of prosthetic vascular grafts through mechanically affirmed material and structure modulation"],"dc:type":["Master Thesis"],"dc:type.publication":["Research"],"dc:type.qualificationlevel":["Masters"],"dc:type.qualificationname":["MSc"],"dc:type.resource":["Thesis"]},"updated_at":"2026-11-21T20:44:06Z"}