{"id":{"repo_id":"cape-town","oai_identifier":"oai:open.uct.ac.za:11427/11684"},"canonical_url":"https://search.ndltd.org/etd/cape-town/oai:open.uct.ac.za:11427/11684","repository":{"repo_id":"cape-town","name":"University of Cape Town","base_url":"https://open.uct.ac.za/oai/request"},"display":{"title":"Design and implementation of a non-contact microwave level measument instrument","abstract":"This dissertation describes the design and implementation of a microwave level measurement instrument for sensing the level of a substance inside a tank up to 10 m in height. A radar transceiver had to be designed to replace an acoustic sensor on an existing 4-20 mA loop powered ultrasonic instrument and had to be compatible with its on-board acoustic signal processing hardware. Specifications are developed for a pulsed radar architecture operating at 5.8 GHz with a bandwidth around 1 GHz and at a repetition frequency of 3.58 MHz.","abstract_html":"This dissertation describes the design and implementation of a microwave level measurement instrument for sensing the level of a substance inside a tank up to 10 m in height. A radar transceiver had to be designed to replace an acoustic sensor on an existing 4-20 mA loop powered ultrasonic instrument and had to be compatible with its on-board acoustic signal processing hardware. Specifications are developed for a pulsed radar architecture operating at 5.8 GHz with a bandwidth around 1 GHz and at a repetition frequency of 3.58 MHz.","abstract_has_math":false,"creators":["Ward, Jonathan Michael"],"institution":"Department of Electrical Engineering","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Inggs, Mike"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-25T21:07:08Z","subjects":["Electrical Engineering"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.apacitation","label":"Dc Identifier Apacitation","values":["Ward, J. M. (2010). <i>Design and implementation of a non-contact microwave level measument instrument</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/11684"],"render_values":[{"text":"Ward, J. M. (2010). <i>Design and implementation of a non-contact microwave level measument instrument</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/11684","href":null,"code":true}]},{"key":"dc:identifier.chicagocitation","label":"Dc Identifier Chicagocitation","values":["Ward, Jonathan Michael. <i>\"Design and implementation of a non-contact microwave level measument instrument.\"</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2010. http://hdl.handle.net/11427/11684"],"render_values":[{"text":"Ward, Jonathan Michael. <i>\"Design and implementation of a non-contact microwave level measument instrument.\"</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2010. http://hdl.handle.net/11427/11684","href":null,"code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ward, J. 2010. Design and implementation of a non-contact microwave level measument instrument. University of Cape Town."],"render_values":[{"text":"Ward, J. 2010. Design and implementation of a non-contact microwave level measument instrument. University of Cape Town.","href":null,"code":true}]},{"key":"dc:identifier.ris","label":"Dc Identifier Ris","values":["TY - Thesis / Dissertation AU - Ward, Jonathan Michael AB - This dissertation describes the design and implementation of a microwave level measurement instrument for sensing the level of a substance inside a tank up to 10 m in height. A radar transceiver had to be designed to replace an acoustic sensor on an existing 4-20 mA loop powered ultrasonic instrument and had to be compatible with its on-board acoustic signal processing hardware. Specifications are developed for a pulsed radar architecture operating at 5.8 GHz with a bandwidth around 1 GHz and at a repetition frequency of 3.58 MHz. DA - 2010 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2010 T1 - Design and implementation of a non-contact microwave level measument instrument TI - Design and implementation of a non-contact microwave level measument instrument UR - http://hdl.handle.net/11427/11684 ER -"],"render_values":[{"text":"TY - Thesis / Dissertation AU - Ward, Jonathan Michael AB - This dissertation describes the design and implementation of a microwave level measurement instrument for sensing the level of a substance inside a tank up to 10 m in height. A radar transceiver had to be designed to replace an acoustic sensor on an existing 4-20 mA loop powered ultrasonic instrument and had to be compatible with its on-board acoustic signal processing hardware. Specifications are developed for a pulsed radar architecture operating at 5.8 GHz with a bandwidth around 1 GHz and at a repetition frequency of 3.58 MHz. DA - 2010 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2010 T1 - Design and implementation of a non-contact microwave level measument instrument TI - Design and implementation of a non-contact microwave level measument instrument UR - http://hdl.handle.net/11427/11684 ER -","href":null,"code":true}]},{"key":"dc:identifier.vancouvercitation","label":"Dc Identifier Vancouvercitation","values":["Ward JM. Design and implementation of a non-contact microwave level measument instrument. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2010 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/11684"],"render_values":[{"text":"Ward JM. Design and implementation of a non-contact microwave level measument instrument. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2010 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/11684","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11427/11684","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11427/11684","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.uct.ac.za/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.uct.ac.za%3A11427%2F11684","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Inggs, Mike"]},{"key":"dc:creator","label":"Author","values":["Ward, Jonathan Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-01-07T13:28:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-01-07T13:28:08Z"]},{"key":"dc:date.issued","label":"Date","values":["2010"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Electrical Engineering"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Faculty of Engineering and the Built Environment"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Cape Town"]},{"key":"dc:type","label":"Dc Type","values":["Master Thesis"]},{"key":"dc:type.publication","label":"Dc Type Publication","values":["Research"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Masters"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["MSc"]},{"key":"dc:type.resource","label":"Dc Type Resource","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.other","label":"Dc Subject Other","values":["Electrical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.apacitation","label":"Dc Identifier Apacitation","values":["Ward, J. M. (2010). <i>Design and implementation of a non-contact microwave level measument instrument</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/11684"]},{"key":"dc:identifier.chicagocitation","label":"Dc Identifier Chicagocitation","values":["Ward, Jonathan Michael. <i>\"Design and implementation of a non-contact microwave level measument instrument.\"</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2010. http://hdl.handle.net/11427/11684"]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ward, J. 2010. Design and implementation of a non-contact microwave level measument instrument. University of Cape Town."]},{"key":"dc:identifier.ris","label":"Dc Identifier Ris","values":["TY - Thesis / Dissertation AU - Ward, Jonathan Michael AB - This dissertation describes the design and implementation of a microwave level measurement instrument for sensing the level of a substance inside a tank up to 10 m in height. A radar transceiver had to be designed to replace an acoustic sensor on an existing 4-20 mA loop powered ultrasonic instrument and had to be compatible with its on-board acoustic signal processing hardware. Specifications are developed for a pulsed radar architecture operating at 5.8 GHz with a bandwidth around 1 GHz and at a repetition frequency of 3.58 MHz. DA - 2010 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2010 T1 - Design and implementation of a non-contact microwave level measument instrument TI - Design and implementation of a non-contact microwave level measument instrument UR - http://hdl.handle.net/11427/11684 ER -"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11427/11684"]},{"key":"dc:identifier.vancouvercitation","label":"Dc Identifier Vancouvercitation","values":["Ward JM. Design and implementation of a non-contact microwave level measument instrument. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2010 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/11684"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Includes abstract.","Includes bibliographical references (leaves 104-110)."]},{"key":"dc:description.abstract","label":"Abstract","values":["This dissertation describes the design and implementation of a microwave level measurement instrument for sensing the level of a substance inside a tank up to 10 m in height. A radar transceiver had to be designed to replace an acoustic sensor on an existing 4-20 mA loop powered ultrasonic instrument and had to be compatible with its on-board acoustic signal processing hardware. Specifications are developed for a pulsed radar architecture operating at 5.8 GHz with a bandwidth around 1 GHz and at a repetition frequency of 3.58 MHz."]},{"key":"dc:format.filetype","label":"Dc Format Filetype","values":["Text","Image"]},{"key":"dc:title","label":"Title","values":["Design and implementation of a non-contact microwave level measument instrument"]}]}],"canonical_facts":{"dc:contributor.advisor":["Inggs, Mike"],"dc:creator":["Ward, Jonathan Michael"],"dc:date.accessioned":["2015-01-07T13:28:08Z"],"dc:date.available":["2015-01-07T13:28:08Z"],"dc:date.issued":["2010"],"dc:description":["Includes abstract.","Includes bibliographical references (leaves 104-110)."],"dc:description.abstract":["This dissertation describes the design and implementation of a microwave level measurement instrument for sensing the level of a substance inside a tank up to 10 m in height. A radar transceiver had to be designed to replace an acoustic sensor on an existing 4-20 mA loop powered ultrasonic instrument and had to be compatible with its on-board acoustic signal processing hardware. Specifications are developed for a pulsed radar architecture operating at 5.8 GHz with a bandwidth around 1 GHz and at a repetition frequency of 3.58 MHz."],"dc:format.filetype":["Text","Image"],"dc:identifier.apacitation":["Ward, J. M. (2010). <i>Design and implementation of a non-contact microwave level measument instrument</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/11684"],"dc:identifier.chicagocitation":["Ward, Jonathan Michael. <i>\"Design and implementation of a non-contact microwave level measument instrument.\"</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2010. http://hdl.handle.net/11427/11684"],"dc:identifier.citation":["Ward, J. 2010. Design and implementation of a non-contact microwave level measument instrument. University of Cape Town."],"dc:identifier.ris":["TY - Thesis / Dissertation AU - Ward, Jonathan Michael AB - This dissertation describes the design and implementation of a microwave level measurement instrument for sensing the level of a substance inside a tank up to 10 m in height. A radar transceiver had to be designed to replace an acoustic sensor on an existing 4-20 mA loop powered ultrasonic instrument and had to be compatible with its on-board acoustic signal processing hardware. Specifications are developed for a pulsed radar architecture operating at 5.8 GHz with a bandwidth around 1 GHz and at a repetition frequency of 3.58 MHz. DA - 2010 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2010 T1 - Design and implementation of a non-contact microwave level measument instrument TI - Design and implementation of a non-contact microwave level measument instrument UR - http://hdl.handle.net/11427/11684 ER -"],"dc:identifier.uri":["http://hdl.handle.net/11427/11684"],"dc:identifier.vancouvercitation":["Ward JM. Design and implementation of a non-contact microwave level measument instrument. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2010 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/11684"],"dc:language.iso":["eng"],"dc:publisher.department":["Department of Electrical Engineering"],"dc:publisher.faculty":["Faculty of Engineering and the Built Environment"],"dc:publisher.institution":["University of Cape Town"],"dc:subject.other":["Electrical Engineering"],"dc:title":["Design and implementation of a non-contact microwave level measument instrument"],"dc:type":["Master Thesis"],"dc:type.publication":["Research"],"dc:type.qualificationlevel":["Masters"],"dc:type.qualificationname":["MSc"],"dc:type.resource":["Thesis"]},"updated_at":"2026-11-25T21:07:08Z"}