{"id":{"repo_id":"cape-town","oai_identifier":"oai:open.uct.ac.za:11427/5083"},"canonical_url":"https://search.ndltd.org/etd/cape-town/oai:open.uct.ac.za:11427/5083","repository":{"repo_id":"cape-town","name":"University of Cape Town","base_url":"https://open.uct.ac.za/oai/request"},"display":{"title":"Design and characterization of the measurement electronics for a magnetic induction tomography imaging system","abstract":"A data acquisition transceiver circuit for magnetic induction tomography (MIT) has been developed. MIT is a type of tomography technique that is sensitive to the conductivity of objects, and which can be used in both industrial and biomedical applications. A detailed design process of the MIT transceiver board and the coupling sensor coils are presented in this dissertation. For the purpose of testing the designed hardware, a three channel MIT measuring system was assembled, and various experiments were run on the system. Several different samples with high conductivity (metal sheets) or low conductivity (saline solution) were used to test the performance of the designed transceiver. Its suitability for being applied to the actual MIT system could then be assessed. The noise characteristics and stability of the system were also characterised. A complete eight channel MIT measurement system is presently being assembled based on the prototypes presented in the dissertation. The results obtained from the experiments are very promising. The construction of the multi-channel MIT system and the image reconstruction can confidently be expected in future development.","abstract_html":"A data acquisition transceiver circuit for magnetic induction tomography (MIT) has been developed. MIT is a type of tomography technique that is sensitive to the conductivity of objects, and which can be used in both industrial and biomedical applications. A detailed design process of the MIT transceiver board and the coupling sensor coils are presented in this dissertation. For the purpose of testing the designed hardware, a three channel MIT measuring system was assembled, and various experiments were run on the system. Several different samples with high conductivity (metal sheets) or low conductivity (saline solution) were used to test the performance of the designed transceiver. Its suitability for being applied to the actual MIT system could then be assessed. The noise characteristics and stability of the system were also characterised. A complete eight channel MIT measurement system is presently being assembled based on the prototypes presented in the dissertation. The results obtained from the experiments are very promising. The construction of the multi-channel MIT system and the image reconstruction can confidently be expected in future development.","abstract_has_math":false,"creators":["Wei, Hsin Yu"],"institution":"Department of Electrical Engineering","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Wilkinson, Andrew John"],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-11-27T21:12:27Z","subjects":["Electrical Engineering"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.apacitation","label":"Dc Identifier Apacitation","values":["Wei, H. Y. (2008). <i>Design and characterization of the measurement electronics for a magnetic induction tomography imaging system</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/5083"],"render_values":[{"text":"Wei, H. Y. (2008). <i>Design and characterization of the measurement electronics for a magnetic induction tomography imaging system</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/5083","href":null,"code":true}]},{"key":"dc:identifier.chicagocitation","label":"Dc Identifier Chicagocitation","values":["Wei, Hsin Yu. <i>\"Design and characterization of the measurement electronics for a magnetic induction tomography imaging system.\"</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2008. http://hdl.handle.net/11427/5083"],"render_values":[{"text":"Wei, Hsin Yu. <i>\"Design and characterization of the measurement electronics for a magnetic induction tomography imaging system.\"</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2008. http://hdl.handle.net/11427/5083","href":null,"code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Wei, H. 2008. Design and characterization of the measurement electronics for a magnetic induction tomography imaging system. University of Cape Town."],"render_values":[{"text":"Wei, H. 2008. Design and characterization of the measurement electronics for a magnetic induction tomography imaging system. University of Cape Town.","href":null,"code":true}]},{"key":"dc:identifier.ris","label":"Dc Identifier Ris","values":["TY - Thesis / Dissertation AU - Wei, Hsin Yu AB - A data acquisition transceiver circuit for magnetic induction tomography (MIT) has been developed. MIT is a type of tomography technique that is sensitive to the conductivity of objects, and which can be used in both industrial and biomedical applications. A detailed design process of the MIT transceiver board and the coupling sensor coils are presented in this dissertation. For the purpose of testing the designed hardware, a three channel MIT measuring system was assembled, and various experiments were run on the system. Several different samples with high conductivity (metal sheets) or low conductivity (saline solution) were used to test the performance of the designed transceiver. Its suitability for being applied to the actual MIT system could then be assessed. The noise characteristics and stability of the system were also characterised. A complete eight channel MIT measurement system is presently being assembled based on the prototypes presented in the dissertation. The results obtained from the experiments are very promising. The construction of the multi-channel MIT system and the image reconstruction can confidently be expected in future development. DA - 2008 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2008 T1 - Design and characterization of the measurement electronics for a magnetic induction tomography imaging system TI - Design and characterization of the measurement electronics for a magnetic induction tomography imaging system UR - http://hdl.handle.net/11427/5083 ER -"],"render_values":[{"text":"TY - Thesis / Dissertation AU - Wei, Hsin Yu AB - A data acquisition transceiver circuit for magnetic induction tomography (MIT) has been developed. MIT is a type of tomography technique that is sensitive to the conductivity of objects, and which can be used in both industrial and biomedical applications. A detailed design process of the MIT transceiver board and the coupling sensor coils are presented in this dissertation. For the purpose of testing the designed hardware, a three channel MIT measuring system was assembled, and various experiments were run on the system. Several different samples with high conductivity (metal sheets) or low conductivity (saline solution) were used to test the performance of the designed transceiver. Its suitability for being applied to the actual MIT system could then be assessed. The noise characteristics and stability of the system were also characterised. A complete eight channel MIT measurement system is presently being assembled based on the prototypes presented in the dissertation. The results obtained from the experiments are very promising. The construction of the multi-channel MIT system and the image reconstruction can confidently be expected in future development. DA - 2008 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2008 T1 - Design and characterization of the measurement electronics for a magnetic induction tomography imaging system TI - Design and characterization of the measurement electronics for a magnetic induction tomography imaging system UR - http://hdl.handle.net/11427/5083 ER -","href":null,"code":true}]},{"key":"dc:identifier.vancouvercitation","label":"Dc Identifier Vancouvercitation","values":["Wei HY. Design and characterization of the measurement electronics for a magnetic induction tomography imaging system. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2008 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/5083"],"render_values":[{"text":"Wei HY. Design and characterization of the measurement electronics for a magnetic induction tomography imaging system. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2008 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/5083","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11427/5083","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11427/5083","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acape-town%3Aoai%3Aopen.uct.ac.za%3A11427%2F5083","prefix":"oai_dc"},"source_record":{"url":"https://open.uct.ac.za/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.uct.ac.za%3A11427%2F5083","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wilkinson, Andrew John"]},{"key":"dc:creator","label":"Author","values":["Wei, Hsin Yu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-07-31T10:51:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-07-31T10:51:21Z"]},{"key":"dc:date.issued","label":"Date","values":["2008"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Electrical Engineering"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Faculty of Engineering and the Built Environment"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Cape Town"]},{"key":"dc:type","label":"Dc Type","values":["Master Thesis"]},{"key":"dc:type.publication","label":"Dc Type Publication","values":["Research"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Masters"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["MSc"]},{"key":"dc:type.resource","label":"Dc Type Resource","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.other","label":"Dc Subject Other","values":["Electrical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.apacitation","label":"Dc Identifier Apacitation","values":["Wei, H. Y. (2008). <i>Design and characterization of the measurement electronics for a magnetic induction tomography imaging system</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/5083"]},{"key":"dc:identifier.chicagocitation","label":"Dc Identifier Chicagocitation","values":["Wei, Hsin Yu. <i>\"Design and characterization of the measurement electronics for a magnetic induction tomography imaging system.\"</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2008. http://hdl.handle.net/11427/5083"]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Wei, H. 2008. Design and characterization of the measurement electronics for a magnetic induction tomography imaging system. University of Cape Town."]},{"key":"dc:identifier.ris","label":"Dc Identifier Ris","values":["TY - Thesis / Dissertation AU - Wei, Hsin Yu AB - A data acquisition transceiver circuit for magnetic induction tomography (MIT) has been developed. MIT is a type of tomography technique that is sensitive to the conductivity of objects, and which can be used in both industrial and biomedical applications. A detailed design process of the MIT transceiver board and the coupling sensor coils are presented in this dissertation. For the purpose of testing the designed hardware, a three channel MIT measuring system was assembled, and various experiments were run on the system. Several different samples with high conductivity (metal sheets) or low conductivity (saline solution) were used to test the performance of the designed transceiver. Its suitability for being applied to the actual MIT system could then be assessed. The noise characteristics and stability of the system were also characterised. A complete eight channel MIT measurement system is presently being assembled based on the prototypes presented in the dissertation. The results obtained from the experiments are very promising. The construction of the multi-channel MIT system and the image reconstruction can confidently be expected in future development. DA - 2008 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2008 T1 - Design and characterization of the measurement electronics for a magnetic induction tomography imaging system TI - Design and characterization of the measurement electronics for a magnetic induction tomography imaging system UR - http://hdl.handle.net/11427/5083 ER -"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11427/5083"]},{"key":"dc:identifier.vancouvercitation","label":"Dc Identifier Vancouvercitation","values":["Wei HY. Design and characterization of the measurement electronics for a magnetic induction tomography imaging system. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2008 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/5083"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Includes abstract.","Includes bibliographical references (p. 103-110)."]},{"key":"dc:description.abstract","label":"Abstract","values":["A data acquisition transceiver circuit for magnetic induction tomography (MIT) has been developed. MIT is a type of tomography technique that is sensitive to the conductivity of objects, and which can be used in both industrial and biomedical applications. A detailed design process of the MIT transceiver board and the coupling sensor coils are presented in this dissertation. For the purpose of testing the designed hardware, a three channel MIT measuring system was assembled, and various experiments were run on the system. Several different samples with high conductivity (metal sheets) or low conductivity (saline solution) were used to test the performance of the designed transceiver. Its suitability for being applied to the actual MIT system could then be assessed. The noise characteristics and stability of the system were also characterised. A complete eight channel MIT measurement system is presently being assembled based on the prototypes presented in the dissertation. The results obtained from the experiments are very promising. The construction of the multi-channel MIT system and the image reconstruction can confidently be expected in future development."]},{"key":"dc:format.filetype","label":"Dc Format Filetype","values":["Text","Image"]},{"key":"dc:title","label":"Title","values":["Design and characterization of the measurement electronics for a magnetic induction tomography imaging system"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wilkinson, Andrew John"],"dc:creator":["Wei, Hsin Yu"],"dc:date.accessioned":["2014-07-31T10:51:21Z"],"dc:date.available":["2014-07-31T10:51:21Z"],"dc:date.issued":["2008"],"dc:description":["Includes abstract.","Includes bibliographical references (p. 103-110)."],"dc:description.abstract":["A data acquisition transceiver circuit for magnetic induction tomography (MIT) has been developed. MIT is a type of tomography technique that is sensitive to the conductivity of objects, and which can be used in both industrial and biomedical applications. A detailed design process of the MIT transceiver board and the coupling sensor coils are presented in this dissertation. For the purpose of testing the designed hardware, a three channel MIT measuring system was assembled, and various experiments were run on the system. Several different samples with high conductivity (metal sheets) or low conductivity (saline solution) were used to test the performance of the designed transceiver. Its suitability for being applied to the actual MIT system could then be assessed. The noise characteristics and stability of the system were also characterised. A complete eight channel MIT measurement system is presently being assembled based on the prototypes presented in the dissertation. The results obtained from the experiments are very promising. The construction of the multi-channel MIT system and the image reconstruction can confidently be expected in future development."],"dc:format.filetype":["Text","Image"],"dc:identifier.apacitation":["Wei, H. Y. (2008). <i>Design and characterization of the measurement electronics for a magnetic induction tomography imaging system</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/5083"],"dc:identifier.chicagocitation":["Wei, Hsin Yu. <i>\"Design and characterization of the measurement electronics for a magnetic induction tomography imaging system.\"</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2008. http://hdl.handle.net/11427/5083"],"dc:identifier.citation":["Wei, H. 2008. Design and characterization of the measurement electronics for a magnetic induction tomography imaging system. University of Cape Town."],"dc:identifier.ris":["TY - Thesis / Dissertation AU - Wei, Hsin Yu AB - A data acquisition transceiver circuit for magnetic induction tomography (MIT) has been developed. MIT is a type of tomography technique that is sensitive to the conductivity of objects, and which can be used in both industrial and biomedical applications. A detailed design process of the MIT transceiver board and the coupling sensor coils are presented in this dissertation. For the purpose of testing the designed hardware, a three channel MIT measuring system was assembled, and various experiments were run on the system. Several different samples with high conductivity (metal sheets) or low conductivity (saline solution) were used to test the performance of the designed transceiver. Its suitability for being applied to the actual MIT system could then be assessed. The noise characteristics and stability of the system were also characterised. A complete eight channel MIT measurement system is presently being assembled based on the prototypes presented in the dissertation. The results obtained from the experiments are very promising. The construction of the multi-channel MIT system and the image reconstruction can confidently be expected in future development. DA - 2008 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2008 T1 - Design and characterization of the measurement electronics for a magnetic induction tomography imaging system TI - Design and characterization of the measurement electronics for a magnetic induction tomography imaging system UR - http://hdl.handle.net/11427/5083 ER -"],"dc:identifier.uri":["http://hdl.handle.net/11427/5083"],"dc:identifier.vancouvercitation":["Wei HY. Design and characterization of the measurement electronics for a magnetic induction tomography imaging system. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2008 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/5083"],"dc:language.iso":["eng"],"dc:publisher.department":["Department of Electrical Engineering"],"dc:publisher.faculty":["Faculty of Engineering and the Built Environment"],"dc:publisher.institution":["University of Cape Town"],"dc:subject.other":["Electrical Engineering"],"dc:title":["Design and characterization of the measurement electronics for a magnetic induction tomography imaging system"],"dc:type":["Master Thesis"],"dc:type.publication":["Research"],"dc:type.qualificationlevel":["Masters"],"dc:type.qualificationname":["MSc"],"dc:type.resource":["Thesis"]},"updated_at":"2026-11-27T21:12:27Z"}