{"id":{"repo_id":"cape-town","oai_identifier":"oai:open.uct.ac.za:11427/9735"},"canonical_url":"https://search.ndltd.org/etd/cape-town/oai:open.uct.ac.za:11427/9735","repository":{"repo_id":"cape-town","name":"University of Cape Town","base_url":"https://open.uct.ac.za/oai/request"},"display":{"title":"The development of an on-chip-metering solution","abstract":"Energy Measurements Ltd (EML), a joint venture partnership between Siemens and Spescom, manufacture prepaid electricity utility meters for both the local and international markets. Under the brand name CASHPOWER 2000, EML produces single and polyphase prepayment utility meters. Currently, these meters currently utilise a separate module for the measuring of electrical energy. In order to reduce component costs, EML proposed the energy measurement be conducted by the onboard Microcontroller Unit (MCU), a term known as On-Chip-Metering (OCM). It is envisioned that this would quickly translate in an increase in revenue. However, a major concern regarding this has been the increase in the required processor overhead. The CASHPOWER 2000 embedded MCU would be required to conduct all the present metering functionality in addition to the energy measurement. This, together with the cost analysis and compliance with the stipulated IEC1036 regulations, constitute the key criteria in determining the projects viability. This dissertation represents the investigative and development stages of a prototype algorithm and accompanying peripheral hardware as a possible solution for OCM. As part of the preliminary research, several examples of digital power and energy-measurement techniques were investigated. A comparative analysis of these was performed to facilitate the development of a unique solution based on the research conducted. This completed, a prototype was developed and preliminary testing was conducted to determine its compliance with the stipulated regulations for a class 2 meter, as per IEC1O36 speciﬁcations.","abstract_html":"Energy Measurements Ltd (EML), a joint venture partnership between Siemens and Spescom, manufacture prepaid electricity utility meters for both the local and international markets. Under the brand name CASHPOWER 2000, EML produces single and polyphase prepayment utility meters. Currently, these meters currently utilise a separate module for the measuring of electrical energy. In order to reduce component costs, EML proposed the energy measurement be conducted by the onboard Microcontroller Unit (MCU), a term known as On-Chip-Metering (OCM). It is envisioned that this would quickly translate in an increase in revenue. However, a major concern regarding this has been the increase in the required processor overhead. The CASHPOWER 2000 embedded MCU would be required to conduct all the present metering functionality in addition to the energy measurement. This, together with the cost analysis and compliance with the stipulated IEC1036 regulations, constitute the key criteria in determining the projects viability. This dissertation represents the investigative and development stages of a prototype algorithm and accompanying peripheral hardware as a possible solution for OCM. As part of the preliminary research, several examples of digital power and energy-measurement techniques were investigated. A comparative analysis of these was performed to facilitate the development of a unique solution based on the research conducted. This completed, a prototype was developed and preliminary testing was conducted to determine its compliance with the stipulated regulations for a class 2 meter, as per IEC1O36 speciﬁcations.","abstract_has_math":false,"creators":["Kaplen, David"],"institution":"Department of Electrical Engineering","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Tapson, Jonathan"],"committee_chairs":[],"committee_members":[],"year":2001,"date_issued":"2001","date_published":"2001","updated_at":"2026-11-18T20:36:54Z","subjects":["Electrical Engineering"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.apacitation","label":"Dc Identifier Apacitation","values":["Kaplen, D. (2001). <i>The development of an on-chip-metering solution</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/9735"],"render_values":[{"text":"Kaplen, D. (2001). <i>The development of an on-chip-metering solution</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/9735","href":null,"code":true}]},{"key":"dc:identifier.chicagocitation","label":"Dc Identifier Chicagocitation","values":["Kaplen, David. <i>\"The development of an on-chip-metering solution.\"</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2001. http://hdl.handle.net/11427/9735"],"render_values":[{"text":"Kaplen, David. <i>\"The development of an on-chip-metering solution.\"</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2001. http://hdl.handle.net/11427/9735","href":null,"code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Kaplen, D. 2001. The development of an on-chip-metering solution. University of Cape Town."],"render_values":[{"text":"Kaplen, D. 2001. The development of an on-chip-metering solution. University of Cape Town.","href":null,"code":true}]},{"key":"dc:identifier.ris","label":"Dc Identifier Ris","values":["TY - Thesis / Dissertation AU - Kaplen, David AB - Energy Measurements Ltd (EML), a joint venture partnership between Siemens and Spescom, manufacture prepaid electricity utility meters for both the local and international markets. Under the brand name CASHPOWER 2000, EML produces single and polyphase prepayment utility meters. Currently, these meters currently utilise a separate module for the measuring of electrical energy. In order to reduce component costs, EML proposed the energy measurement be conducted by the onboard Microcontroller Unit (MCU), a term known as On-Chip-Metering (OCM). It is envisioned that this would quickly translate in an increase in revenue. However, a major concern regarding this has been the increase in the required processor overhead. The CASHPOWER 2000 embedded MCU would be required to conduct all the present metering functionality in addition to the energy measurement. This, together with the cost analysis and compliance with the stipulated IEC1036 regulations, constitute the key criteria in determining the projects viability. This dissertation represents the investigative and development stages of a prototype algorithm and accompanying peripheral hardware as a possible solution for OCM. As part of the preliminary research, several examples of digital power and energy-measurement techniques were investigated. A comparative analysis of these was performed to facilitate the development of a unique solution based on the research conducted. This completed, a prototype was developed and preliminary testing was conducted to determine its compliance with the stipulated regulations for a class 2 meter, as per IEC1O36 speciﬁcations. DA - 2001 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2001 T1 - The development of an on-chip-metering solution TI - The development of an on-chip-metering solution UR - http://hdl.handle.net/11427/9735 ER -"],"render_values":[{"text":"TY - Thesis / Dissertation AU - Kaplen, David AB - Energy Measurements Ltd (EML), a joint venture partnership between Siemens and Spescom, manufacture prepaid electricity utility meters for both the local and international markets. Under the brand name CASHPOWER 2000, EML produces single and polyphase prepayment utility meters. Currently, these meters currently utilise a separate module for the measuring of electrical energy. In order to reduce component costs, EML proposed the energy measurement be conducted by the onboard Microcontroller Unit (MCU), a term known as On-Chip-Metering (OCM). It is envisioned that this would quickly translate in an increase in revenue. However, a major concern regarding this has been the increase in the required processor overhead. The CASHPOWER 2000 embedded MCU would be required to conduct all the present metering functionality in addition to the energy measurement. This, together with the cost analysis and compliance with the stipulated IEC1036 regulations, constitute the key criteria in determining the projects viability. This dissertation represents the investigative and development stages of a prototype algorithm and accompanying peripheral hardware as a possible solution for OCM. As part of the preliminary research, several examples of digital power and energy-measurement techniques were investigated. A comparative analysis of these was performed to facilitate the development of a unique solution based on the research conducted. This completed, a prototype was developed and preliminary testing was conducted to determine its compliance with the stipulated regulations for a class 2 meter, as per IEC1O36 speciﬁcations. DA - 2001 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2001 T1 - The development of an on-chip-metering solution TI - The development of an on-chip-metering solution UR - http://hdl.handle.net/11427/9735 ER -","href":null,"code":true}]},{"key":"dc:identifier.vancouvercitation","label":"Dc Identifier Vancouvercitation","values":["Kaplen D. The development of an on-chip-metering solution. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2001 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/9735"],"render_values":[{"text":"Kaplen D. The development of an on-chip-metering solution. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2001 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/9735","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11427/9735","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11427/9735","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acape-town%3Aoai%3Aopen.uct.ac.za%3A11427%2F9735","prefix":"oai_dc"},"source_record":{"url":"https://open.uct.ac.za/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.uct.ac.za%3A11427%2F9735","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Tapson, Jonathan"]},{"key":"dc:creator","label":"Author","values":["Kaplen, David"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-11-20T03:54:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-11-20T03:54:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2001"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Electrical Engineering"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Faculty of Engineering and the Built Environment"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Cape Town"]},{"key":"dc:type","label":"Dc Type","values":["Master Thesis"]},{"key":"dc:type.publication","label":"Dc Type Publication","values":["Research"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Masters"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["MSc"]},{"key":"dc:type.resource","label":"Dc Type Resource","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.other","label":"Dc Subject Other","values":["Electrical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.apacitation","label":"Dc Identifier Apacitation","values":["Kaplen, D. (2001). <i>The development of an on-chip-metering solution</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/9735"]},{"key":"dc:identifier.chicagocitation","label":"Dc Identifier Chicagocitation","values":["Kaplen, David. <i>\"The development of an on-chip-metering solution.\"</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2001. http://hdl.handle.net/11427/9735"]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Kaplen, D. 2001. The development of an on-chip-metering solution. University of Cape Town."]},{"key":"dc:identifier.ris","label":"Dc Identifier Ris","values":["TY - Thesis / Dissertation AU - Kaplen, David AB - Energy Measurements Ltd (EML), a joint venture partnership between Siemens and Spescom, manufacture prepaid electricity utility meters for both the local and international markets. Under the brand name CASHPOWER 2000, EML produces single and polyphase prepayment utility meters. Currently, these meters currently utilise a separate module for the measuring of electrical energy. In order to reduce component costs, EML proposed the energy measurement be conducted by the onboard Microcontroller Unit (MCU), a term known as On-Chip-Metering (OCM). It is envisioned that this would quickly translate in an increase in revenue. However, a major concern regarding this has been the increase in the required processor overhead. The CASHPOWER 2000 embedded MCU would be required to conduct all the present metering functionality in addition to the energy measurement. This, together with the cost analysis and compliance with the stipulated IEC1036 regulations, constitute the key criteria in determining the projects viability. This dissertation represents the investigative and development stages of a prototype algorithm and accompanying peripheral hardware as a possible solution for OCM. As part of the preliminary research, several examples of digital power and energy-measurement techniques were investigated. A comparative analysis of these was performed to facilitate the development of a unique solution based on the research conducted. This completed, a prototype was developed and preliminary testing was conducted to determine its compliance with the stipulated regulations for a class 2 meter, as per IEC1O36 speciﬁcations. DA - 2001 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2001 T1 - The development of an on-chip-metering solution TI - The development of an on-chip-metering solution UR - http://hdl.handle.net/11427/9735 ER -"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11427/9735"]},{"key":"dc:identifier.vancouvercitation","label":"Dc Identifier Vancouvercitation","values":["Kaplen D. The development of an on-chip-metering solution. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2001 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/9735"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Includes bibliographical references."]},{"key":"dc:description.abstract","label":"Abstract","values":["Energy Measurements Ltd (EML), a joint venture partnership between Siemens and Spescom, manufacture prepaid electricity utility meters for both the local and international markets. Under the brand name CASHPOWER 2000, EML produces single and polyphase prepayment utility meters. Currently, these meters currently utilise a separate module for the measuring of electrical energy. In order to reduce component costs, EML proposed the energy measurement be conducted by the onboard Microcontroller Unit (MCU), a term known as On-Chip-Metering (OCM). It is envisioned that this would quickly translate in an increase in revenue. However, a major concern regarding this has been the increase in the required processor overhead. The CASHPOWER 2000 embedded MCU would be required to conduct all the present metering functionality in addition to the energy measurement. This, together with the cost analysis and compliance with the stipulated IEC1036 regulations, constitute the key criteria in determining the projects viability. This dissertation represents the investigative and development stages of a prototype algorithm and accompanying peripheral hardware as a possible solution for OCM. As part of the preliminary research, several examples of digital power and energy-measurement techniques were investigated. A comparative analysis of these was performed to facilitate the development of a unique solution based on the research conducted. This completed, a prototype was developed and preliminary testing was conducted to determine its compliance with the stipulated regulations for a class 2 meter, as per IEC1O36 speciﬁcations."]},{"key":"dc:format.filetype","label":"Dc Format Filetype","values":["Text","Image"]},{"key":"dc:title","label":"Title","values":["The development of an on-chip-metering solution"]}]}],"canonical_facts":{"dc:contributor.advisor":["Tapson, Jonathan"],"dc:creator":["Kaplen, David"],"dc:date.accessioned":["2014-11-20T03:54:50Z"],"dc:date.available":["2014-11-20T03:54:50Z"],"dc:date.issued":["2001"],"dc:description":["Includes bibliographical references."],"dc:description.abstract":["Energy Measurements Ltd (EML), a joint venture partnership between Siemens and Spescom, manufacture prepaid electricity utility meters for both the local and international markets. Under the brand name CASHPOWER 2000, EML produces single and polyphase prepayment utility meters. Currently, these meters currently utilise a separate module for the measuring of electrical energy. In order to reduce component costs, EML proposed the energy measurement be conducted by the onboard Microcontroller Unit (MCU), a term known as On-Chip-Metering (OCM). It is envisioned that this would quickly translate in an increase in revenue. However, a major concern regarding this has been the increase in the required processor overhead. The CASHPOWER 2000 embedded MCU would be required to conduct all the present metering functionality in addition to the energy measurement. This, together with the cost analysis and compliance with the stipulated IEC1036 regulations, constitute the key criteria in determining the projects viability. This dissertation represents the investigative and development stages of a prototype algorithm and accompanying peripheral hardware as a possible solution for OCM. As part of the preliminary research, several examples of digital power and energy-measurement techniques were investigated. A comparative analysis of these was performed to facilitate the development of a unique solution based on the research conducted. This completed, a prototype was developed and preliminary testing was conducted to determine its compliance with the stipulated regulations for a class 2 meter, as per IEC1O36 speciﬁcations."],"dc:format.filetype":["Text","Image"],"dc:identifier.apacitation":["Kaplen, D. (2001). <i>The development of an on-chip-metering solution</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/9735"],"dc:identifier.chicagocitation":["Kaplen, David. <i>\"The development of an on-chip-metering solution.\"</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2001. http://hdl.handle.net/11427/9735"],"dc:identifier.citation":["Kaplen, D. 2001. The development of an on-chip-metering solution. University of Cape Town."],"dc:identifier.ris":["TY - Thesis / Dissertation AU - Kaplen, David AB - Energy Measurements Ltd (EML), a joint venture partnership between Siemens and Spescom, manufacture prepaid electricity utility meters for both the local and international markets. Under the brand name CASHPOWER 2000, EML produces single and polyphase prepayment utility meters. Currently, these meters currently utilise a separate module for the measuring of electrical energy. In order to reduce component costs, EML proposed the energy measurement be conducted by the onboard Microcontroller Unit (MCU), a term known as On-Chip-Metering (OCM). It is envisioned that this would quickly translate in an increase in revenue. However, a major concern regarding this has been the increase in the required processor overhead. The CASHPOWER 2000 embedded MCU would be required to conduct all the present metering functionality in addition to the energy measurement. This, together with the cost analysis and compliance with the stipulated IEC1036 regulations, constitute the key criteria in determining the projects viability. This dissertation represents the investigative and development stages of a prototype algorithm and accompanying peripheral hardware as a possible solution for OCM. As part of the preliminary research, several examples of digital power and energy-measurement techniques were investigated. A comparative analysis of these was performed to facilitate the development of a unique solution based on the research conducted. This completed, a prototype was developed and preliminary testing was conducted to determine its compliance with the stipulated regulations for a class 2 meter, as per IEC1O36 speciﬁcations. DA - 2001 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2001 T1 - The development of an on-chip-metering solution TI - The development of an on-chip-metering solution UR - http://hdl.handle.net/11427/9735 ER -"],"dc:identifier.uri":["http://hdl.handle.net/11427/9735"],"dc:identifier.vancouvercitation":["Kaplen D. The development of an on-chip-metering solution. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2001 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/9735"],"dc:language.iso":["eng"],"dc:publisher.department":["Department of Electrical Engineering"],"dc:publisher.faculty":["Faculty of Engineering and the Built Environment"],"dc:publisher.institution":["University of Cape Town"],"dc:subject.other":["Electrical Engineering"],"dc:title":["The development of an on-chip-metering solution"],"dc:type":["Master Thesis"],"dc:type.publication":["Research"],"dc:type.qualificationlevel":["Masters"],"dc:type.qualificationname":["MSc"],"dc:type.resource":["Thesis"]},"updated_at":"2026-11-18T20:36:54Z"}