{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/27193"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/27193","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Critical heat flux in horizontal and vertical 37-element nuclear fuel bundles","abstract":"The flow models for critical heat flux in flow boiling in tubes and rod bundle geometries are reviewed. Sadeghlou's C6D correlation for vertical 37-element bundles at 1000 psia is reviewed and the significance of the Becker-type quality correction factors for geometry/ pressure/ radial flux depression/ heat flux and bundle junction end plates are examined. A CHF correlation for vertical 37-element bundles is presented which describes the available high mass flux data with an rms error of 4.3%.The effect of buoyant forces on CHF in horizontal flow tubes is reviewed. A brief review of the principles of similitude and modeling along with a description of their application to Freon-to-water modeling in CHF experiments is given. Ahmad's [7] method of compensated distortion is described and his scaling flow parameter fervertical orientations presented. Meri lo' s [8] development of adimensionless scaling flow parameter for horizontal tubes is described. Using the techniques of Ahmad and Merilo, and CHF data from 37-element bundles cooled by Freon and by water, a scalin9 flow parameter for horizontal conditions in 37-element bundles is developed. Using this scaling flow parameter, the calculation of water-equivalent results from Freon-12 CHF data is described. A CHF correlation for horizontal 37-element CANDU bundles is present~d, which describes the water-equivalent data and the actual water data in the range of interest with a rms error of 4.4%. The application of this CHF correlation to the design of CANDU fuel channels is discussed and the benefits of the use of this correlation over the current approach are stated.","abstract_html":"The flow models for critical heat flux in flow boiling in tubes and rod bundle geometries are reviewed. Sadeghlou&#x27;s C6D correlation for vertical 37-element bundles at 1000 psia is reviewed and the significance of the Becker-type quality correction factors for geometry/ pressure/ radial flux depression/ heat flux and bundle junction end plates are examined. A CHF correlation for vertical 37-element bundles is presented which describes the available high mass flux data with an rms error of 4.3%.The effect of buoyant forces on CHF in horizontal flow tubes is reviewed. A brief review of the principles of similitude and modeling along with a description of their application to Freon-to-water modeling in CHF experiments is given. Ahmad&#x27;s [7] method of compensated distortion is described and his scaling flow parameter fervertical orientations presented. Meri lo&#x27; s [8] development of adimensionless scaling flow parameter for horizontal tubes is described. Using the techniques of Ahmad and Merilo, and CHF data from 37-element bundles cooled by Freon and by water, a scalin9 flow parameter for horizontal conditions in 37-element bundles is developed. Using this scaling flow parameter, the calculation of water-equivalent results from Freon-12 CHF data is described. A CHF correlation for horizontal 37-element CANDU bundles is present~d, which describes the water-equivalent data and the actual water data in the range of interest with a rms error of 4.4%. The application of this CHF correlation to the design of CANDU fuel channels is discussed and the benefits of the use of this correlation over the current approach are stated.","abstract_has_math":false,"creators":["Atkinson, John Clayton"],"institution":"Carleton University","degree_name":"Master of Engineering (M.Eng.)","degree_level":"Master's","degree_discipline":"Engineering, Mechanical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1981,"date_issued":"1981","date_published":"1981","updated_at":"2026-11-19T07:00:28Z","subjects":["Nuclear Fuel Elements -- Thermal Properties"],"languages":["en"],"rights":["Copyright © 1981 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/27193"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/27193","href":"https://hdl.handle.net/20.500.14718/27193","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/1981-12293","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/1981-12293","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F27193","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Atkinson, John Clayton"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T16:23:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T16:23:21Z"]},{"key":"dc:date.issued","label":"Date","values":["1981"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Mechanical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Engineering (M.Eng.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Nuclear Fuel Elements -- Thermal Properties"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 1981 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/1981-12293"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/27193"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The flow models for critical heat flux in flow boiling in tubes and rod bundle geometries are reviewed. Sadeghlou's C6D correlation for vertical 37-element bundles at 1000 psia is reviewed and the significance of the Becker-type quality correction factors for geometry/ pressure/ radial flux depression/ heat flux and bundle junction end plates are examined. A CHF correlation for vertical 37-element bundles is presented which describes the available high mass flux data with an rms error of 4.3%.The effect of buoyant forces on CHF in horizontal flow tubes is reviewed. A brief review of the principles of similitude and modeling along with a description of their application to Freon-to-water modeling in CHF experiments is given. Ahmad's [7] method of compensated distortion is described and his scaling flow parameter fervertical orientations presented. Meri lo' s [8] development of adimensionless scaling flow parameter for horizontal tubes is described. Using the techniques of Ahmad and Merilo, and CHF data from 37-element bundles cooled by Freon and by water, a scalin9 flow parameter for horizontal conditions in 37-element bundles is developed. Using this scaling flow parameter, the calculation of water-equivalent results from Freon-12 CHF data is described. A CHF correlation for horizontal 37-element CANDU bundles is present~d, which describes the water-equivalent data and the actual water data in the range of interest with a rms error of 4.4%. The application of this CHF correlation to the design of CANDU fuel channels is discussed and the benefits of the use of this correlation over the current approach are stated."]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["This work is available on request. You can request a copy at https://library.carleton.ca/forms/request-pdf-copy-thesis"]},{"key":"dc:title","label":"Title","values":["Critical heat flux in horizontal and vertical 37-element nuclear fuel bundles"]},{"key":"others:access_status","label":"Others Access Status","values":["metadata.only"]}]}],"canonical_facts":{"dc:creator":["Atkinson, John Clayton"],"dc:date.accessioned":["2025-04-08T16:23:21Z"],"dc:date.available":["2025-04-08T16:23:21Z"],"dc:date.issued":["1981"],"dc:description.abstract":["The flow models for critical heat flux in flow boiling in tubes and rod bundle geometries are reviewed. Sadeghlou's C6D correlation for vertical 37-element bundles at 1000 psia is reviewed and the significance of the Becker-type quality correction factors for geometry/ pressure/ radial flux depression/ heat flux and bundle junction end plates are examined. A CHF correlation for vertical 37-element bundles is presented which describes the available high mass flux data with an rms error of 4.3%.The effect of buoyant forces on CHF in horizontal flow tubes is reviewed. A brief review of the principles of similitude and modeling along with a description of their application to Freon-to-water modeling in CHF experiments is given. Ahmad's [7] method of compensated distortion is described and his scaling flow parameter fervertical orientations presented. Meri lo' s [8] development of adimensionless scaling flow parameter for horizontal tubes is described. Using the techniques of Ahmad and Merilo, and CHF data from 37-element bundles cooled by Freon and by water, a scalin9 flow parameter for horizontal conditions in 37-element bundles is developed. Using this scaling flow parameter, the calculation of water-equivalent results from Freon-12 CHF data is described. A CHF correlation for horizontal 37-element CANDU bundles is present~d, which describes the water-equivalent data and the actual water data in the range of interest with a rms error of 4.4%. The application of this CHF correlation to the design of CANDU fuel channels is discussed and the benefits of the use of this correlation over the current approach are stated."],"dc:identifier.doi":["10.22215/etd/1981-12293"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/27193"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 1981 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Nuclear Fuel Elements -- Thermal Properties"],"dcterms:accessrights":["This work is available on request. You can request a copy at https://library.carleton.ca/forms/request-pdf-copy-thesis"],"dc:title":["Critical heat flux in horizontal and vertical 37-element nuclear fuel bundles"],"dc:type":["thesis"],"others:access_status":["metadata.only"],"thesis:degree_discipline":["Engineering, Mechanical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Engineering (M.Eng.)"]},"updated_at":"2026-11-19T07:00:28Z"}